PubMed Health⌕ Search

Biomedical subjects

J Webster Stayman

Publications and source records attributed to J Webster Stayman.

2 recordsLinked to original sources

Compensation for nonuniform resolution using penalized-likelihood reconstruction in space-variant imaging systems.

Imaging systems that form estimates using a statistical approach generally yield images with nonuniform resolution properties. That is, the reconstructed images possess resolution properties marked by space-variant and/or anisotropic responses. We have previously developed a space-variant penalty for penalized-likelihood (PL) reconstruction that yields nearly uniform resolution properties. We demonstrated how to calculate this penalty efficiently and apply it to an idealized positron emission tomography (PET) system whose geometric response is space-invariant. In this paper, we demonstrate the efficient calculation and application of this penalty to space-variant systems. (The method is most appropriate when the system matrix has been precalculated.) We apply the penalty to a large field of view PET system where crystal penetration effects make the geometric response space-variant, and to a two-dimensional single photon emission computed tomography system whose detector responses are modeled by a depth-dependent Gaussian with linearly varying full-width at half-maximum. We perform a simulation study comparing reconstructions using our proposed PL approach with other reconstruction methods and demonstrate the relative resolution uniformity, and discuss tradeoffs among estimators that yield nearly uniform resolution. We observe similar noise performance for the PL and post-smoothed maximum-likelihood (ML) approaches with carefully matched resolution, so choosing one estimator over another should be made on other factors like computational complexity and convergence rates of the iterative reconstruction. Additionally, because the postsmoothed ML and the proposed PL approach can outperform one another in terms of resolution uniformity depending on the desired reconstruction resolution, we present and discuss a hybrid approach adopting both a penalty and post-smoothing.

Algorithms↗

Efficient calculation of resolution and covariance for penalized-likelihood reconstruction in fully 3-D SPECT.

Resolution and covariance predictors have been derived previously for penalized-likelihood estimators. These predictors can provide accurate approximations to the local resolution properties and covariance functions for tomographic systems given a good estimate of the mean measurements. Although these predictors may be evaluated iteratively, circulant approximations are often made for practical computation times. However, when numerous evaluations are made repeatedly (as in penalty design or calculation of variance images), these predictors still require large amounts of computing time. In Stayman and Fessler (2000), we discussed methods for precomputing a large portion of the predictor for shift-invariant system geometries. In this paper, we generalize the efficient procedure discussed in Stayman and Fessler (2000) to shift-variant single photon emission computed tomography (SPECT) systems. This generalization relies on a new attenuation approximation and several observations on the symmetries in SPECT systems. These new general procedures apply to both two-dimensional and fully three-dimensional (3-D) SPECT models, that may be either precomputed and stored, or written in procedural form. We demonstrate the high accuracy of the predictions based on these methods using a simulated anthropomorphic phantom and fully 3-D SPECT system. The evaluation of these predictors requires significantly less computation time than traditional prediction techniques, once the system geometry specific precomputations have been made.

Abdomen↗