The incidence and management of failed Pipelle sampling in a general outpatient clinic.

A prospective audit was performed on 100 consecutive patients who underwent Pipelle endometrial sampling in a general outpatient clinic setting. The indications for sampling were abnormal menstrual bleeding (AMB, 65), intermenstrual or postcoital bleeding (IMB/PCB, 7), postmenopausal bleeding (PMB, 28). An insufficient sample was obtained in 33 women: (AMB 14, 21.5%); IMB/PCB, (0); PMB 19,68%). In 3 women the Pipelle was unable to be introduced through the cervix; in the remainder an insufficient sample for histological diagnosis was obtained. Registrars and resident doctors were more likely to sample insufficiently. In the AMB group all but 1 woman with an insufficient sample had further investigations or treatment but 7 of 19 (37%) of PMB patients had no further investigations. Where definitive histology was available, endometrial polyps or submucous fibroids were found in half of the cases with an inadequate Pipelle sample. Pipelle sampling detected only 1 of the 2 cases of endometrial cancer in this study.

Adult↗

Four channel foetal ECG data collection system.

Recently there has been an increased interest in the development of improved techniques for the diagnosis of foetal distress during labour. Many of the techniques have been based on extracting extra information from the foetal ECG obtained from a scalp electrode. To fully develop and test the prototypes of these systems requires recorded data from patients. However due to the poor level of prediction of these cases at present, it is very difficult to collect the data using simple single channel data collection systems. The system described here will automatically collect and document data from up to four deliveries at the same time and does not add to the work load of the clinical staff.

Biomedical Engineering↗

Suitability of artificial neural networks for feature extraction from cardiotocogram during labour.

Fetal condition during labour is inferred from a continuous display of fetal heart rate and uterine contractions called the cardiotocogram (CTG). The CTG requires a considerable expertise for correct interpretation, which is not always available. We are developing an intelligent system to support clinical decision-making during labour. The system's performance depends on its ability to classify features from the CTG similarly to experts. Artificial neural networks (NNs) can be taught by experts for such tasks, and so may be particularly suitable. We found NNs suitable for feature extraction when the problem was reduced to small well defined tasks, and numerical algorithms were used to pre-process the raw data before application to the NNs. A NN with optimised dimensions was used in this way to classify the magnitude of decelerations, a feature clinicians find particularly difficult. The NN was compared with the algorithm used in a commercial antenatal monitor and six reviewers which included two CTG experts. The experts were consistent (89.7% and 97.0%) and agreed well with each other (81.0%), whereas the non-experts were less consistent and agreed less well. The NN agreed well with the experts (75.0% and 81.9%) but the algorithm agreed poorly (56.5% and 68.9%). It was found that the algorithm's performance could be improved (72.1% and 76.7%) when modified to use additional information. Our earlier attempts to fully classify the raw CTG using a single NN were unsuccessful because of the large number of data patterns. A simplified approach to classify the magnitude and timing of decelerations was also unsuitable when contraction data was of poor quality or absent.(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

Umbilical cord blood gas analysis at delivery: a time for quality data.

OBJECTIVES: To address the practical problems of routine umbilical cord blood sampling, to determine the ranges for pH, PCO2 and base deficit and to examine the relationships of these parameters between cord vessels. DESIGN: An observational study of umbilical cord artery and vein blood gas results. SETTING: A large district general hospital in the UK. SUBJECTS: One thousand nine hundred and forty-two cord results from 2013 consecutive pregnancies of 34 weeks or more gestation, monitored by fetal scalp electrode during labour. RESULTS: Only 1448 (74.6%) of the 1942 supposedly paired samples had validated pH and PCO2 data both from an artery and the vein; 54 (2.8%) had only one blood sample available, 90 (4.6%) had an error in the pH or PCO2 of one vessel and in 350 (18%) pairs the differences between vessels indicated that they were not sampled from artery and vein as intended. Only 60% of the cases with an arterial pH less than 7.05 had evidence of a metabolic acidosis (base deficit in the extracellular fluid 10 mmol/l or more). Of all the cases, 2.5% had a venous-arterial pH difference greater than 0.22 units. CONCLUSIONS: Both artery and vein cord samples must be taken and the results screened to ensure separate vessels have been sampled. Interpretation of the results requires the examination of PCO2 and base deficit of the extracellular fluid from each vessel as well as the pH. Confusion about the value of cord gas measurements may be due to the use of erroneous data and inadequate definitions of acidosis which do not differentiate between respiratory and metabolic components.

Carbon Dioxide↗

Preliminary evaluation of an intelligent system for the management of labour.

Over the past 10-15 years, workers using conventional computing approaches have attempted to provide an accurate assessment of fetal condition during labour based on the cardiotocogram (CTG) alone. These have not proved successful perhaps because the correct interpretation of fetal condition also requires physiological knowledge, specific patient information, knowledge of events during labour and considerable practical experience. An intelligent system which considers all the relevant information and embodies expertise may better diagnose fetal condition and support decision making. This study reports the preliminary evaluation of such a system and investigates whether this approach can attain a performance comparable with experienced local clinicians. From a database of 200 high risk labour records, 30 cases were selected; the 9 cases which received clinical intervention for 'fetal-distress' and a further 21 cases selected randomly. The management specified by the system, 3 experienced clinicians (A, B and C) and the actual clinical management were compared in a retrospective blinded review. The experts were found to agree well with each other. Expert A reviewed the cases five months later and was found to be entirely consistent in the management of 28 of the 30 cases. The system's actions were indistinguishable from the experts' and in no case did the system recommend an action not also recommended by at least one experienced reviewer. This study demonstrates the potential of an intelligent system to assist in the management of labour.

Artificial Intelligence↗

Plymouth randomized trial of cardiotocogram only versus ST waveform plus cardiotocogram for intrapartum monitoring in 2400 cases.

OBJECTIVE: The physiology of changes in the ST waveform of the fetal electrocardiogram has been elucidated in extensive animal and human observational studies. A combination of heart rate and ST waveform analysis might improve the predictive value of intrapartum monitoring. Our purpose was to compare operative intervention and neonatal outcome in labors monitored by the conventional cardiotocogram with those monitored by ST waveform plus the cardiotocogram. STUDY DESIGN: A prospective, randomized clinical trial was performed on 2434 high-risk labors in a district general hospital in Plymouth, England. Statistical analysis was performed by Student t test and chi 2 analysis. RESULTS: There was a 46% reduction (p < 0.001, odds ratio 1.85 [1.35-2.66]) in operative deliveries for "fetal distress" and a trend to less metabolic acidosis (p = 0.09, odds ratio 0.38 [0.13-1.07]) and fewer low 5-minute Apgar scores (p = 0.12, odds ratio 0.62 [0.35-1.08]) in the ST waveform plus cardiotocogram arm. CONCLUSIONS: ST waveform analysis discriminates cardiotocogram changes in labor, and the protocol for interpretation is safe. Further randomized studies are warranted.

Blood Gas Analysis↗

Randomised trial of cardiotocography alone or with ST waveform analysis for intrapartum monitoring.

It is possible to record the fetal electrocardiographic waveform (ECG) from the scalp electrode used in labour for detection of fetal heart rate. Animal and observational studies of changes in the ST waveform of the ECG during hypoxia suggest that a combination of heart rate and ST waveform analysis might improve the predictive value of intrapartum monitoring. In a randomised trial, we have studied intervention rates and neonatal outcome for high-risk labours monitored either by conventional cardiotocography (CTG) or by ST waveform analysis plus CTG. 1200 women with pregnancy of at least 34 weeks' gestation were assigned to the groups when the decision to apply a fetal scalp electrode was made. Neonatal outcome was assessed by umbilical-cord blood gas analysis, Apgar scores, resuscitation needed, and postnatal course. All recordings were retrospectively viewed by an observer unaware of clinical details to check adherence to the trial protocol. The addition of ST waveform monitoring to CTG substantially reduced the proportion of deliveries for fetal distress (ST + CTG 27/615 vs CTG 58/606; p less than 0.001). The groups did not differ in rate of operative delivery for other reasons, incidence of asphyxia at birth, or neonatal outcome. Metabolic acidosis and low 5 min Apgar scores were less common in the ST + CTG than the CTG group, but not significantly so. The only case of birth asphyxia in the ST + CTG group was identified by both heart rate and ST changes. The review of recordings showed that the reduction in intervention rate was among cases with CTG patterns classified as normal or intermediate, whereas there was no difference in intervention rates among cases with abnormal recordings. Our findings confirm that ST waveform analysis discriminates CTG changes in labour and that our protocol for interpretation is safe. Further randomised studies are warranted.

Adult↗

Suitability of fetal scalp electrodes for monitoring the fetal electrocardiogram during labour.

As the limitations of heart-rate based intrapartum monitoring have become apparent, there is renewed interest in analysis of the fetal electrocardiographic waveform as obtained from a fetal scalp electrode. A high quality ECG signal is necessary for waveform analysis. This study examined the suitability of five commonly available scalp electrodes for collecting this signal by examining their physical and electrical characteristics, together with a randomised clinical trial in which the ECG trace quality was assessed in 50 patients. The frequency response of Copeland electrodes was such that they attenuate the ECG signal more than the baseline noise. Difficulties were experienced in obtaining optimum attachment and the long, semi-rigid design increased movement artefact resulting in significantly poorer quality ECG signals. Whilst the Hewlett-Packard double spiral electrode had a near ideal frequency response, certain design features made it difficult to apply and remain secure so the clinical signals were of intermediate quality. The Corometrics and Cetro single spirals had the most stable attachment to the scalp and a near ideal frequency response, so produced significantly better signal quality in the clinical trial. Currently, single spiral electrodes are the most suitable for electrocardiographic data collection.

Electrocardiography↗

Stillbirths and fetal movements.

The unexplained stillbirth is an event distressing to patients, families and medical attendants alike. Many of these deaths can be prevented by the use of fetal movement record cards. In a retrospective study of stillbirths occurring over two consecutive twenty-month periods, the first twenty-month period being prior to, the second subsequent to the introduction of fetal movement record cards on a non-prescriptive basis a significant decrease in perinatal mortality and stillbirth rates was observed. The percentage of patients using fetal movement record cards in the second time period cannot be estimated, but in only one of twenty-seven unexplained stillbirths was the mother using a fetal movement record card. Examination of antenatal records for hospital clinic patients suffering unexplained stillbirths shows that systematic enquiry about fetal activity was absent in the first time period and rare in the second time period.

Female↗