PubMed Health⌕ Search

Biomedical subjects

J Weyde

Publications and source records attributed to J Weyde.

2 recordsLinked to original sources

Analysis of single and double-stained alveolar macrophages by flow cytometry.

The quantification of cell surface antigens on human alveolar macrophages using flow cytometry is complicated by strong autofluorescence which varies with cell size and granularity. We report here a new method for overcoming the analytical problems caused by autofluorescence. After positioning the unstained cells along the 0, 0; 10(4), 10(4) diagonal on all three fluorescence dot-plots (FL1 vs. FL2; FL2 vs. FL3; FL1 vs. FL3) of a single-laser flow cytometer (excitation wavelength at 488 nm) and adjusting compensation so that the reference FL3 channel profile is not changed by PE-staining, the cell population on the FL3 histogram is arbitrarily classified into subpopulations having similar autofluorescence intensity. These are subsequently back-gated onto the FL1 vs. FL2 dot-plot and separately analyzed. The percentage of stained cells in the whole population is then calculated on the basis of absolute numbers or as the weighted mean of all the subpopulations. This approach permits the analysis not only of single-stained but also double-stained human alveolar macrophages.

Antigens, Surface↗

Lung function changes and exercise-induced ventilatory responses to external resistive loads in normal subjects.

AIM: The aim of this study was (1) to assess the value of common lung function variables in the follow-up of patients with obstructive lesions of the larynx and trachea and (2) to study the respiratory response to progressive upper airway stenosis at rest and during exercise. METHODS: Lung function tests, including vital capacity (VC), residual volume (RV), total body plethysmographic resistance (RT), specific body plethysmographic resistance (Rs), total body plethysmographic resistance at low inspiratory/expiratory flows (Rlo), forced expiratory volume in 1 s (FEV1), peak expiratory flow rate (PEF), peak inspiratory flow rate (PIF), maximum expiratory flow at 50% VC(MEF50) and maximum inspiratory flow at 50% VC(MIF50) were performed in 14 normal subjects with added external resistive loads (inner diameter of circular orifice: 15, 10, 8, 6 mm; equivalent to surface areas of 177, 79, 50 and 28 mm2, respectively), applied in random order. The relative sensitivity of each variable to detect a stepwise decrease in orifice size by evoking 'relevant' obstructive responses was calculated. In addition, ventilatory and gaz exchange responses to loaded breathing (10-, 8- and 6-mm orifices, randomly inserted) during steady-state bicycle exercise (80 and 160 W) were assessed in a subgroup of 10 subjects. RESULTS: The gradual increase of external load did not influence static lung volumes (VC, RV). MEF50/MIF50 (1.63 +/- 1.03 at baseline) remained essentially unchanged, consistent with the rigid nature of the obstructive device. PEF was superior in reproducing the transition from unloaded over mild (15 mm) and moderate (10 mm) to high grade (8 mm) central obstruction. Except for mild loads, PIF was equal in sensitivity to PEF. At high grade (8 mm) and severe loads (6 mm), no difference in sensitivity could be established between RT, Rs, FEV1, PIF and PEF. However, they were all superior to Rlo. Compared to unloaded breathing, ventilation across the 10- and 8-mm orifices at both rest and exercise produced a continuous significant increase in oxygen uptake (VO2). Respiratory rate (RR) fell, and a simultaneous enlargement of tidal volume (VT) was observed to maintain or even enhance minute ventilation (VE). However, ventilation across the 6 mm orifice was associated with a substantial decline in VO2, VCO2 and VE relative to the preceding load (8 mm) CONCLUSIONS: It is suggested that the experimental use of inspiratory and expiratory extrinsic loads can mimic rigid obstructive lesions of the larynx and trachea. Among all conventional lung function values, PEF and, to a certain degree, PIF, seem to be the best suitable follow-up parameters to assess airway mechanics before and after surgical/endoscopic procedures. Upper airway stenosis involving surface areas of no more than 50 mm2 can be overcome using adequate respiratory compensation. But any additional narrowing below this limit will result in hypoventilation, inappropriate oxygen uptake and retention of CO2. Thus, experimental evidence indicates that laryngotracheal obstruction within a critical range below 50 mm2 surface area (diameter of circular orifice < 8 mm) compromises respiratory efforts enough to be of clinical importance.

Adult↗