[Variation in X-ray dose quantity using an amorphous selenium based flat-panel detector -- a study on the dose reduction rate up to the limit of diagnostical utilization].

PURPOSE: To evaluate the diagnostic quality and minimum required dose to obtain acceptable images for diagnostic purposes in the field of musculoskeletal radiology. MATERIALS AND METHODS: A critical comparison of the image quality produced by a novel flat panel detector and the conventional screen/film system using a contrast-detail phantom was performed in phase I. Images from both systems were obtained with the same dose and displayed with similar contrast and density. In phase II images of significant anatomical structures in cadaver extremities obtained using the digital detector system and the standard film/screen system were critically evaluated. After a successive reduction in the X-ray dose for 84 patients in phase III, eight independent radiologists compared the image quality of the screen/film system to that of the novel flat panel detector. RESULTS: Phases I and II revealed a difference in the image quality achieved by the standard screen/film system and the digital detector system to the advantage of the digital detector system. In 77 of 84 patients (91.7 %), phase III showed equal image quality after a 50 % reduction in the X-ray dose. In 3 cases (3.6 %) the image quality and the level of contrast were better. No unified statement could be made for 4 patients (4.7 %). CONCLUSION: Digital imaging of skeletal disorders using the novel flat panel detector makes it possible to reduce the X-ray dose by 50 % with equal or even better image quality.

Adult↗

Analysis of oxidative degradation products of 2,4,6-trichlorophenol treated with air ions.

The analysis of oxidative degradation products of 2,4,6-trichlorophenol (TCP) treated with air ions, which are generated by electric discharge, is reported. Due to the complex nature of the degradation products, a combination of different detection techniques was employed to characterize them. The oxidative degradation of TCP is usually dependent on the treating approaches, and in this system, a stepwise degradation, beginning with the formation of a major product 2,6-dichloro-1,4-benzenediol as well as other minor ones (e.g., 3,5-dichlorocatechol) via substitution, is first proposed through a detailed analysis of GC/MS, etc., though some chromogenic quinones can transiently be present. Furthermore, high dechlorination (53%) was observed for TCP after a 60-min treatment, indicating that air ions can serve as an efficient dechlorination means.

Air↗