PubMed Health⌕ Search

Biomedical subjects

J Y Lo

Publications and source records attributed to J Y Lo.

At least 37 records · Page 2Linked to original sources

Vancomycin and amikacin in cell cultures for virus isolation.

Contamination of cell cultures for virus isolation has been increasingly encountered. By reviewing and changing the antimicrobials incorporated in cell culture media, we aim to control this problem. Contaminated cell culture fluids were inoculated for bacterial and fungal isolation, identification and antibacterial susceptibility testing. Based on the above results, vancomycin and amikacin were chosen to replace the penicillin and gentamicin used conventionally. Analysis was carried out on various characteristics of cell culture with respect to antimicrobial change. All contaminating Gram-positive bacteria were susceptible to vancomycin while about 80% of the Gram-negative bacteria were sensitive to amikacin. The new antimicrobial combination was not toxic to cell cultures and both antimicrobials were found to remain stable in media for over six months. The virus isolation rate was maintained after antimicrobial change while the contamination rate was reduced from nearly 10% to 1.5%. We thus conclude that vancomycin and amikacin can well replace the conventional penicillin and gentamicin to be incorporated into maintenance and transport media to control the emerging problem of viral culture contamination.

Age Factors↗

Artificial neural network: improving the quality of breast biopsy recommendations.

PURPOSE: To evaluate the performance and inter- and intraobserver variability of an artificial neural network (ANN) for predicting breast biopsy outcome. MATERIALS AND METHODS: Five radiologists described 60 mammographically detected lesions with the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) nomenclature. A previously programmed ANN used the BI-RADS descriptors and patient histories to predict biopsy results. ANN predictive performance was compared with the clinical decision to perform biopsy. Inter- and intraobserver variability of radiologists' interpretations and ANN predictions were evaluated with Cohen kappa analysis. RESULTS: The ANN maintained 100% sensitivity (23 of 23 cancers) while improving the positive predictive value of biopsy results from 38% (23 of 60 lesions) to between 58% (23 of 40 lesions) and 66% (23 of 35 lesions; P < .001). Interobserver variability for interpretation of the lesions was significantly reduced by the ANN (P < .001); there was no statistically significant effect on nearly perfect intraobserver reproducibility. CONCLUSION: Use of an ANN with radiologists' descriptions of abnormal findings may improve interpretation of mammographic abnormalities.

Biopsy↗

Diffuse nodular lung disease on chest radiographs: a pilot study of characterization by fractal dimension.

OBJECTIVE: We present a computer-aided diagnostic technique for identifying nodular interstitial lung disease on chest radiographs. The fractal dimension was used as a numerical measure of image texture on digital chest radiographs to distinguish patients with normal lung from those with a diffuse nodular interstitial abnormality. MATERIALS AND METHODS: Twenty digitized chest radiographs were classified as normal (n = 10) or as containing diffuse nodular abnormality (n = 10) on the basis of readings assigned according to the classification of the International Labour Organization. Regions of interest (ROIs) measuring 1.28 cm2 were selected from the intercostal spaces of these radiographs. The fractal dimension of these ROIs was estimated by power spectrum analysis. The cases were not subtle. RESULTS: The fractal dimension provided statistically significant discrimination between normal parenchyma and nodular interstitial lung disease. The area under the receiver operating characteristic curve was 0.90 (+/- 0.02). One operating point provides sensitivity of 88% with a specificity of 80%. CONCLUSION: The fractal dimension can provide a measure of lung parenchymal texture and shows promise as an element of computer-aided diagnosis, characterization, and follow-up of interstitial lung disease.

Fractals↗

Lipoprotein lipase: role of intramolecular disulfide bonds in enzyme catalysis.

Lipoprotein lipase (LPL) catalyzes the hydrolysis of the triacylglycerol component of triacylglycerol-rich lipoproteins. There are 4 cysteine pairs that are completely conserved among LPLs of all species known. We examined the functional importance of each of the cysteine pairs in enzyme catalysis by examining LPLs produced in Cos cells by transfection. Immunoreactive LPL was produced by vectors encoding the wildtype LPL and each of the 4 cysteine-pair mutant LPLs. Enzyme activity was detectable in the wildtype enzyme, but not in 3 of the 4 Cys-->Ser mutant enzymes (C216S/C239S, C264S/C275S, and C278S/C283S). Interestingly, LPL activity was also present in the mutant (C418S/C438S), which affects the C-terminal cysteine pair, with a specific activity approximately 50% higher than that of wildtype. There is evidence that LPL contains two distinct domains consisting of the N-terminal three-quarters of the sequence connected by a flexible region to the C-terminal domain comprising the rest of the molecule. The conservation of catalytic function despite the disruption of the only disulfide bridge in the C-terminal domain of LPL indicates that the two domains can function independently of each other in enzyme catalysis.

Amino Acid Sequence↗

Computer-aided diagnosis of breast cancer: artificial neural network approach for optimized merging of mammographic features.

RATIONALE AND OBJECTIVES: An artificial neural network (ANN) approach was developed for the computer-aided diagnosis of mammography using an optimally minimized number of input features. METHODS: A backpropagation ANN merged nine input features (age plus eight radiographic findings extracted by radiologists) to predict biopsy outcome as its output. The features were ranked, and more important ones were selected to produce an optimal subset of features. RESULTS: Given all nine features, the ANN performed with a receiver operator characteristic area under the curve (Az) of .95 +/- .01. Given only the four most important features, the ANN performed with an Az of .96 +/- .01. Although not significantly better than the ANN with all nine features, the ANN with the four optimized features was significantly better than expert radiologists' Az of .90 +/- .02 (p = .01). This four-feature ANN had a 95% sensitivity and an 81% specificity. For cases with calcifications, the radiologists' performance dropped to an Az of .85 +/- .04, whereas a specialized three-feature ANN performed significantly better with an Az of .95 +/- .02 (p = .02). CONCLUSION: Given only four input features, the ANN predicted biopsy outcome significantly better than did expert radiologists, who also had access to other radiographic and nonradiographic data. The reduced number of features would substantially decrease data entry efforts and potentially improve the ANN's general applicability.

Breast Neoplasms↗

Breast cancer: prediction with artificial neural network based on BI-RADS standardized lexicon.

PURPOSE: To determine if an artificial neural network (ANN) to categorize benign and malignant breast lesions can be standardized for use by all radiologists. MATERIALS AND METHODS: An ANN was constructed based on the standardized lexicon of the Breast Imaging Recording and Data System (BI-RADS) of the American College of Radiology. Eighteen inputs to the network included 10 BI-RADS lesion descriptors and eight input values from the patient's medical history. The network was trained and tested on 206 cases (133 benign, 73 malignant cases). Receiver operating characteristic curves for the network and radiologists were compared. RESULTS: At a specified output threshold, the ANN would have improved the positive predictive value (PPV) of biopsy from 35% to 61% with a relative sensitivity of 100%. At a fixed sensitivity of 95%, the specificity of the ANN (62%) was significantly greater than the specificity of radiologists (30%) (P < .01). CONCLUSION: The BI-RADS lexicon provides a standardized language between mammographers and an ANN that can improve the PPV of breast biopsy.

Adult↗

Prediction of breast cancer malignancy using an artificial neural network.

BACKGROUND: An artificial neural network (ANN) was developed to predict breast cancer from mammographic findings. This network was evaluated in a retrospective study. METHODS: For a set of patients who were scheduled for biopsy, radiologists interpreted the mammograms and provided data on eight mammographic findings as part of the standard mammographic workup. These findings were encoded as features for an ANN. Results of biopsies were taken as truth in the diagnosis of malignancy. The ANN was trained and evaluated using a jackknife sampling on a set of 260 patient records. Performance of the network was evaluated in terms of sensitivity and specificity over a range of decision thresholds and was expressed as a receiver operating characteristic curve. RESULTS: The ANN performed more accurately than the radiologists (P < 0.08) with a relative sensitivity of 1.0 and specificity of 0.59. CONCLUSIONS: An ANN can be trained to predict malignancy from mammographic findings with a high degree of accuracy.

Algorithms↗

Bayesian restoration of chest radiographs. Scatter compensation with improved signal-to-noise ratio.

OBJECTIVES: The authors introduce a Bayesian algorithm for digital chest radiography that increases the signal-to-noise ratio, and thus detectability, for low-contrast objects. METHOD: The improved images are formed as a maximum a posteriori probability estimation of a scatter-reduced (contrast-enhanced) image with decreased noise. Noise is constrained by including prior knowledge of image smoothness. Variations between neighboring pixels are penalized for small variations (to suppress Poisson noise), but not for larger variations (to avoid affecting anatomical structure). The technique was optimized to reduce residual scatter in digital radiographs of an anatomical chest phantom. RESULTS: The contrast in the lung was improved by a factor of two, whereas signal-to-noise ratio was improved by a factor of 1.8. Image resolution was unaffected for objects with a contrast greater than 2%. CONCLUSION: This statistical estimation technique shows promise for improving object detectability in radiographs by simultaneously increasing contrast, while constraining noise.

Algorithms↗

Scatter compensation in digital chest radiography using the posterior beam stop technique.

A new scatter compensation technique for computed radiography based on posterior beam stop (PBS) sampled scatter measurements and the bicubic spline interpolation technique was proposed. Using only a single exposure, both the clinical image and an array of scatter measurements, which were interpolated into a smooth scatter-only image, were simultaneously acquired. The scatter was subtracted from the clinical image to generate the primary-only image. To gauge the accuracy of scatter estimation, both quantitative and interpolation errors were evaluated. The PBS measurements were compared against the standard beam stop method at 16 locations in an anatomical phantom, resulting in quantitative errors of 2.7% relative to the scatter or 6.8% relative to the primary. Also measured were the interpolation error over 64 interpolation sample locations and 64 midpoint sample locations in the anatomical phantom. The combined interpolation error was 1.9% relative to the scatter or 8.0% relative to the primary. At the interpolation sample locations, the errors were identical between the phantom radiograph and digital portable chest radiographs from five patients. By summing the quantitative and interpolation errors in quadrature, the overall error of the PBS SISTER (scatter interpolation-subtraction technique for radiography) method was 3.3% relative to the scatter or 10% relative to the primary, which was adequate for dual-energy imaging purposes (less than 10% error relative to the scatter or 20% relative to the primary). The change of image contrast, noise, and signal-to-noise ratio (SNR) at six locations in the anatomical phantom were quantitatively analyzed. Contrast and noise were equally enhanced in all anatomical regions, resulting in approximately the same SNR before and after compensation.(ABSTRACT TRUNCATED AT 250 WORDS)

Algorithms↗

Scatter compensation for digital chest radiography using maximum likelihood expectation maximization.

RATIONALE AND OBJECTIVES: An iterative maximum likelihood expectation maximization algorithm (MLEM) has been developed for scatter compensation in chest radiography. METHODS: The MLEM technique produces a scatter-reduced image which maximizes the probability of observing the measured image. We examined the scatter content and the low-contrast signal-to-noise ratio (SNR) in digital radiographs of anatomical phantoms before and after compensation. RESULTS: MLEM converged to an accurate (6.4% RMS residual scatter error) estimate within 12 iterations. Both contrast and noise were increased in the processed images as iteration progressed. In the lung, contrast was increased 108% and SNR was improved by 10%. In the retrocardiac region, contrast was increased 180% while SNR decreased by 6%. CONCLUSIONS: This is the first report of a post-acquisition scatter compensation technique which can increase SNR. These results suggest that statistical estimation techniques can enhance image quality and quantitative accuracy for digital chest radiography.

Algorithms↗

Observer evaluation of scatter subtraction for digital portable chest radiographs.

RATIONALE AND OBJECTIVES: The authors compared standard digital portable chest radiographs (DPCXR) to scatter-subtracted DPCXR: METHODS: Thirty DPCXR were obtained using a photostimulable phosphor digital imaging system and a posterior beam stop (PBS) technique that allowed measurement of the scatter component of the DPCXR: The scatter component was subtracted from the clinical image to form a scatter-subtracted image. Six observers recorded preference for the standard image or scatter-subtracted image for identifying five radiographic landmarks and for image quality. RESULTS: A statistically significant preference was demonstrated for the scatter-subtracted images and for viewing the tracheo-bronchial tree, right paratracheal stripe, vertebral column, and support apparatus position. For unprocessed images, there was a statistically significant preference for viewing the pulmonary vasculature. No statistically significant preference was demonstrated for overall image quality. CONCLUSIONS: These results suggest that PBS scatter subtraction holds promise for improving visualization of structures in high-scatter regions of chest radiographs.

Evaluation Studies as Topic↗

Measurement of scatter fractions in erect posteroanterior and lateral chest radiography.

Scatter fractions (SFs) measured in patients undergoing erect posteroanterior (PA) and lateral chest radiography with a 12:1 antiscatter grid are reported. Modifications to the posterior beam-stop (PBS) technique allowed measurement of scatter in these patients, without altering the diagnostic image and without additional radiation exposure. The SF measurements are reported by anatomic location on 42 clinical chest images. Average SF values ranged from 0.27 to 0.90 on lateral radiographs and from 0.27 to 0.68 on PA radiographs. Scatter measurements with the 12:1 grid were found to be greater than estimates from previous PA chest phantom experiments. To the authors' knowledge, they were the first to measure radiation scatter with the PBS technique in patients undergoing PA and lateral chest radiography with the antiscatter grid.

Adult↗

Production of biologically active recombinant human lactoferrin in Aspergillus oryzae.

We report the production of recombinant human lactoferrin in Aspergillus oryzae. Expression of human lactoferrin (hLF), a 78 kD glycoprotein, was achieved by placing the cDNA under the control of the A. oryzae alpha-amylase promoter and the 3' flanking region of the A. niger glucoamylase gene. Using this system, hLF is expressed and secreted into the growth medium at levels up to 25 mg/l. The recombinant lactoferrin is indistinguishable from human milk lactoferrin with respect to its size, immunoreactivity, and iron-binding capacity. The recombinant protein appears to be appropriately N-linked glycosylated and correctly processed at the N-terminus by the A. oryzae secretory apparatus. Lactoferrin is the largest heterologous protein and the first mammalian glycoprotein expressed in the Aspergillus system to date. Hence, this expression system appears suitable for the large-scale production and secretion of biologically active mammalian glycoproteins.

Amino Acid Sequence↗

Thermostable, salt tolerant, wide pH range novel chitobiase from Vibrio parahemolyticus: isolation, characterization, molecular cloning, and expression.

A chitobiase gene from Vibrio parahemolyticus was cloned into plasmid pUC18 in Escherichia coli strain DH5 alpha. The plasmid construct, pC120, contained a 6.4 kb Vibrio DNA insert. The recombinant gene expressed chitobiase [EC 3.2.1.30] activity similar to that found in the native Vibrio. The enzyme was purified by ion exchange, hydroxylapatite and gel permeation chromatographies, and exhibited an apparent molecular weight of 80 kDa on SDS-polyacrylamide gel electrophoresis. Chitobiose and 6 more substrates, including beta-N-acetyl galactosamine glycosides, were hydrolyzed by the recombinant chitobiase, indicating its putative classification as an hexosaminidase [EC 3.2.1.52]. The enzyme was resistant to denaturation by 2 M NaCl, thermostable at 45 degrees C and active over a very unusual (for glycosyl hydrolases) pH range, from 4 to 10. The purified cloned chitobiase gave 4 closely focussed bands on an isoelectric focusing gel, at pH 4 to 6.5. The N-terminal 43 amino acid sequence shows no homology with other proteins in commercial databanks or in the literature, and from its N-terminal sequence, appears to be a novel protein, unrelated in sequence to chitobiases from other Vibrios reported and unrelated to hexosaminidases from other organisms.

Acetylglucosaminidase↗

Posterior beam-stop method for scatter fraction measurement in digital radiography.

The authors presented a new posterior beam-stop (PBS) technique for measuring the ratio of scattered to total-detected photon flux (scatter fraction) in a radiographic examination while preserving the diagnostic quality of the image. The scatter measurement was made using a standard imaging geometry with both beam stops and an additional x-ray detector placed behind the standard imaging detector. This PBS geometry differs from the standard beam-stop (SBS) technique for scatter measurement. With SBS, a beam-stop shadow appears on the image. To evaluate the PBS technique, scatter fraction measurements were performed on an anatomic phantom using both the PBS and SBS techniques. When compared with the standard technique, PBS provided accurate estimation of scatter fractions. Since the measurement can be performed without degrading a standard clinical radiographic examination, the PBS technique allows simultaneous acquisition of scatter measurements from human patients in combination with a standard radiographic examination.

Filtration↗

Measurement of scatter fractions in clinical bedside radiography.

The authors present measurements of scatter fraction (SF), the ratio of scattered to total imaged photons, from clinical bedside radiographs of 102 patients. These measurements were obtained by using a new posterior beam-stop technique that does not alter the diagnostic image but that simultaneously provides SF measurements at 224 locations in the image. The SF values in the lung were found to be consistent with previous measurements, while the SF values in the mediastinal and retrocardiac areas were larger than previously reported. SFs in diseased lung were significantly larger than SFs in normal lung. The range of SF values was large for all anatomic locations. For applications in which accurate scatter estimation is required, this wide range of values suggests that SFs should be measured in each individual image.

Female↗

Scatter fractions in AMBER imaging.

Images of two phantoms were obtained with use of an advanced multiple-beam equalization radiography system, and scatter fractions were estimated with use of a photostimulable phosphor imaging system. Scatter fractions in the equalized images were lower in the mediastinum-equivalent areas and higher in the lung-equivalent areas, relative to images that were conventionally acquired with use of an antiscatter grid. The differences are attributed to a reduction in incident exposure in the lungs and the presence of cross-scatter between lung and mediastinal regions.

Radiography, Thoracic↗