PubMed Health⌕ Search

Biomedical subjects

J Yoshikawa

Publications and source records attributed to J Yoshikawa.

At least 19 recordsLinked to original sources

Increased levels of vascular endothelial growth factor in induced sputum in asthmatic patients.

BACKGROUND: Vascular endothelial growth factor (VEGF) is highly expressed in the airway of asthmatic patients. As VEGF increases airway vascular permeability, consequent thickening of the airway wall mucosa may lead to narrowing of the airway lumen. OBJECTIVE: We evaluated the relationship between VEGF levels in induced sputum and eosinophilic inflammatory profiles, and the degree of airway vascular permeability in asthmatic patients and we evaluated the effect of inhaled corticosteroids on VEGF levels in induced sputum. METHODS: Induced sputum specimens were obtained from 28 glucocorticosteroids free asthmatics and 11 healthy control subjects. We examined VEGF levels and airway vascular permeability index in induced sputum. After the initial sputum induction, 21 asthmatics received 8-week inhaled beclomethasone dipropionate (BDP, 800 micro g/day) therapy, then sputum induction was repeated. RESULTS: The VEGF levels in asthmatics were significantly higher than in healthy control subjects (P < 0.0001). The VEGF levels were negatively correlated with forced expiratory volume of 1 s (FEV1, % predicted, r = - 0.68, P < 0.001), the percentage of eosinophils (r = 0.51, P < 0.01) and ECP levels (r = 0.39, P < 0.05). Moreover, the VEGF levels were significantly correlated with airway vascular permeability index (r = 0.61, P < 0.001). After 8-week inhaled BDP therapy, the VEGF levels were significantly decreased compared to pretreatment levels (P < 0.0001) and the VEGF levels were significantly correlated with airway vascular permeability index even in post-treatment asthmatics (r = 0.62, P < 0.01). CONCLUSION: The VEGF levels in induced sputum were increased in asthmatics and its levels were associated with degree of airway narrowing and airway vascular permeability. These findings provide strong evidence that VEGF may play an important role in the pathogenesis of bronchial asthma.

Adult↗

Assessment of myocardial viability using coronary zero flow pressure after successful angioplasty in patients with acute anterior myocardial infarction.

OBJECTIVES: To investigate the relation between coronary flow reserve (CFR), coronary zero flow pressure (Pzf), and residual myocardial viability in patients with acute myocardial infarction. DESIGNS: Prospective study. SETTING: Primary care hospital. PATIENTS: 27 consecutive patients with acute anterior myocardial infarction. MAIN OUTCOME MEASURES: F-fluorodeoxyglucose (FDG) positron emission tomography (PET) was used in 27 patients who underwent successful intervention within 12 hours of onset of a first acute anterior myocardial infarction. Within three days before discharge they had < 25% stenosis in the culprit lesion as determined by angiography 24 (3) days after acute myocardial infarction. Pzf and the slope index of the flow-pressure relation (SIFP) were calculated from the simultaneously recorded aortic pressure and coronary flow velocity signals at peak hyperaemia.%FDG was quantified by comparing FDG uptake in the infarct myocardium with FDG uptake in the normal myocardium. RESULTS: There was a correlation between %FDG and CFR, where y = -1.477x + 62.517, r = -0.072 (NS). There was also a correlation between %FDG and SIFP, where y = -0.975x + 60.542, r = -0.045 (NS), and a significant correlation between %FDG and Pzf, where y = -0.98x + 85.108, r = -0.696 (p < 0.001). CONCLUSIONS: CFR does not correlate with FDG-PET at the time of postreperfusion evaluation of residual myocardial viability. The parameter that correlates best with residual myocardial viability is Pzf and this may be a useful index for predicting patient prognosis.

Aged↗

Coronary flow velocity analysis during short term follow up after coronary reperfusion: use of transthoracic Doppler echocardiography to predict regional wall motion recovery in patients with acute myocardial infarction.

BACKGROUND: A recent study using a Doppler guide wire showed that coronary flow velocity measurements immediately after coronary reperfusion were useful in predicting recovery of regional left ventricular function. The value of coronary flow velocity analyses during follow up after reperfusion has not been established in the clinical setting. OBJECTIVE: To evaluate coronary flow velocity measurements in predicting recovery of regional left ventricular function during short term follow up after acute anterior myocardial infarction, using transthoracic Doppler echocardiography (TTDE). METHODS: 30 consecutive patients with anterior acute myocardial infarction were studied. They all underwent successful coronary angioplasty for lesions in the left anterior descending coronary artery (LAD). Using TTDE, coronary flow velocity in the LAD was recorded on days 1 and 3, and at one and two weeks after reperfusion. Regional wall motion was analysed by the wall motion score index (WMSI), calculated as an average of segmental scores in the LAD territory before reperfusion and one month after the infarction. RESULTS: Deceleration time of diastolic flow velocity (DDT) in patients with viable myocardium (WMSI in LAD territory at one month, < 2.0) was significantly longer after recanalisation than in patients without viable myocardium (WMSI in LAD territory at one month, > 2.0): 657 (226) v 271 (117) ms on day 1, p < 0.001; 732 (219) v 373 (217) ms on day 3, p < 0.01; and 903 (107) v 577 (300) ms at one week, p < 0.01. However, the difference at two weeks (991 (75) v 795 (281) ms) was not significant. For the prediction of viable myocardium, DDT > 600 ms had a sensitivity of 78% and a specificity of 92% on day 1, and a sensitivity of 78% and a specificity of 84% on day 3. At one and two weeks, DDT > 600 ms was sensitive (100% and 100%, respectively) but less specific (46% and 26%, respectively) for predicting viable myocardium. CONCLUSIONS: Non-invasive assessment of coronary flow velocity using TTDE within three days of successful coronary angioplasty in patients with anterior acute myocardial infarction is useful in predicting recovery of regional left ventricular function.

Blood Flow Velocity↗

Assessment of myocardial perfusion abnormalities by intravenous myocardial contrast echocardiography with harmonic power Doppler imaging: comparison with positron emission tomography.

BACKGROUND: Intravenous myocardial contrast echocardiography with harmonic power Doppler imaging (HPDI) enables assessment of myocardial perfusion. Its accuracy in comparison with positron emission tomography (PET), which is one of the most reliable clinical gold standards for myocardial perfusion, remains to be determined. OBJECTIVE: To assess the ability of HPDI to identify myocardial perfusion abnormalities, using PET as a gold standard. METHODS: 23 patients with myocardial infarction underwent HPDI. Images were obtained from the apical two and four chamber views at pulsing intervals of one to eight cardiac cycles with continuous infusion of Levovist (Schering, Germany). PET was done within two weeks of HPDI. The left ventricle was divided into 12 segments and myocardial opacification by HPDI and uptake of NH(3) by PET in each segment was graded as normal, mildly reduced, or severely reduced. RESULTS: Of the 276 segments examined, adequate image quality was obtained in 226 (82%) by HPDI; 50 segments were excluded because of inadequate image quality. There were more exclusions in the basal segments than in the mid or apical segments (p < 0.0001). Of the 226 segments analysed, overall concordance between HPDI and PET was 82% (chi = 0.70). In the apex, more segments were overestimated by HPDI than were underestimated (chi(2) = 6.25, p = 0.012). CONCLUSIONS: HPDI and PET gave similar results in the assessment of myocardial perfusion abnormalities. However, poor image quality in the basal segments and overestimation of perfusion in the apical segments are current limitations of HPDI.

Adult↗

Real time quantification of low temperature radiofrequency ablation lesion size using phased array intracardiac echocardiography in the canine model: comparison of two dimensional images with pathological lesion characteristics.

OBJECTIVE: To evaluate the feasibility of quantifying low temperature radiofrequency catheter ablation (RFCA) lesions using a phased array intracardiac echocardiography (ICE) catheter--with better tissue penetration and in a deflectable device-in the canine model. INTERVENTION: Low temperature radiofrequency (RF) energy (50-60 degrees C at up to 40 W) was delivered to the left ventricle in 11 beagles for 60 seconds, using an 8 French catheter with a deflectable tip and a 4 mm distal electrode. MAIN OUTCOME MEASURES: Comparison of the width and depth of RFCA lesions measured by ICE with pathological findings. RESULTS: 33 RF energies were delivered in 11 dogs. 31 lesions (94%) were confirmed at necropsy. 27 of 31 ablation lesions (87%) were detected by ICE. The mean (SD) width and depth of the ICE detected lesions were 10.4 (2.6) mm and 5.7 (1.9) mm, respectively. Pathological findings showed that RFCA lesions consisted of inner and outer layers. Macroscopically, the mean (SD) width and depth of the inner layers were 7.6 (2.3) mm and 3.6 (1.2) mm and those for the whole layers were 10.0 (2.8) mm and 5.3 (1.5) mm, respectively. Microscopically, the inner and outer layers corresponded to necrotic and oedematous areas, respectively. The ICE detected lesion size had better correlation with the pathological measurements of the whole layers in width (r = 0.911) and in depth (r = 0.756). CONCLUSION: The real time evaluation of RFCA lesion size using the phased array ICE is feasible, even with a low temperature RF application. However, ICE slightly overestimates RFCA lesion size compared with pathological necrotic lesion size.

Animals↗

Imbalance between levels of nitrogen oxides and peroxynitrite inhibitory activity in chronic obstructive pulmonary disease.

BACKGROUND: The prevalent theory concerning the pathogenesis of chronic obstructive pulmonary disease (COPD) is of an imbalance between oxidants and antioxidants in the lung. It has recently been reported that the production of peroxynitrite, an extremely potent oxidant, is increased in the airways of patients with COPD. A study was undertaken of the imbalance between the levels of nitrogen oxides and antioxidant activity against peroxynitrite in the airways of patients with COPD. METHODS: Sputum induction was performed in 30 patients with COPD and 15 normal control subjects. Levels of nitrogen oxides, percentage of neutrophils, and interleukin 8 (IL-8) levels were measured in sputum samples, and peroxynitrite inhibitory activity was assayed by monitoring rhodamine formation. RESULTS: Nitrite and nitrate levels in induced sputum were significantly higher in patients with COPD than in normal controls (949 (133) microM v 621 (89) microM, p<0.001). In contrast, peroxynitrite inhibitory activity in induced sputum was significantly lower in patients with COPD than in normal controls (47.4 (12.7)% v 92.9 (3.9)%, p<0.001). There was a negative correlation between nitrite and nitrate levels and peroxynitrite inhibitory activity in induced sputum (r=-0.775, p<0.001). Peroxynitrite inhibitory activity was also significantly correlated with forced expiratory volume in 1 second (FEV(1)) % predicted (r=0.539, p=0.004), FEV(1)/FVC (r=0.512, p=0.006), and carbon monoxide transfer factor (TLCO) (r=0.486, p=0.009). Moreover, there was a significant negative correlation between peroxynitrite inhibitory activity and the degree of neutrophilic inflammation (percentage of neutrophils: r=-0.754, p<0.001; IL-8 levels: r=-0.497, p=0.007). CONCLUSIONS: Reduced peroxynitrite inhibitory activity and increased levels of nitrogen oxides are found in induced sputum from patients with COPD. An imbalance in nitrogen oxides and antioxidant defence may contribute to the pathogenesis of COPD.

Female↗

Effects of captopril administration on pulmonary haemodynamics and tissue oxygenation during exercise in ACE gene subtypes in patients with COPD: a preliminary study.

BACKGROUND: We have previously shown that angiotensin converting enzyme (ACE) DD genotype is associated with exaggerated pulmonary hypertension and disturbance of tissue oxygenation during exercise in patients with chronic obstructive pulmonary disease (COPD). A pilot study was designed to examine the effects of captopril on these exercise related variables in COPD patients categorised according to ACE gene polymorphisms. METHODS: Thirty six patients with COPD (II=13, ID=11, DD=12) received oral captopril (25 mg) or placebo in a randomised, double blind, crossover manner and underwent right heart catheterisation with exercise. RESULTS: Mean pulmonary arterial pressure (mPAP), pulmonary vascular resistance (PVR), and lactate concentration after exercise with both placebo and captopril were higher in patients with the DD genotype than in those with the II or ID genotypes. In contrast, mixed venous oxygen tension (PvO(2)) was lower in patients with the DD genotype than in those with the other genotypes. Moreover, mPAP, PVR, and lactate concentration after exercise were lower in the captopril group than in the placebo group in patients with the II or ID genotype, but not in those with the DD genotype. PvO(2) after exercise was higher with captopril than with placebo in patients with the II genotype, but not in those with the other genotypes. CONCLUSIONS: These findings suggest that pulmonary haemodynamic variables and state of tissue oxygenation during exercise are dependent on ACE genotypes, and that captopril administration effectively influences these exercise related variables. Although the sample size in this pilot study was limited, it is likely that the improvement in exercise related variables in COPD patients with the II genotype is relatively sensitive to captopril.

Angiotensin-Converting Enzyme Inhibitors↗

Non-invasive automated assessment of the ratio of pulmonary to systemic flow in patients with atrial septal defects by the colour Doppler velocity profile integration method.

BACKGROUND: The recent introduction of the automated cardiac flow measurement (ACM) method, using spatiotemporal integration of the Doppler velocity profile, provides a quick and accurate automated calculation of cardiac output. OBJECTIVE: To evaluate the ACM method against oximetry during cardiac catheterisation for estimating the Qp/Qs (pulmonary to systemic flow) ratio in patients with an atrial septal defect. METHODS: Left and right ventricular stroke volume (LVSV, RVSV) were calculated by ACM in 22 patients with an atrial septal defect who underwent cardiac catheterisation and in 11 patients without heart disease (control group). With ACM, the Qp/Qs ratio was estimated from RVSV divided by LVSV. In the patients with an atrial septal defect, the Qp/Qs ratio was assessed by oximetry at the time of cardiac catheterisation. RESULTS: There was a good correlation between LVSV and RVSV obtained by ACM in the control group (r = 0.98, y = 0.97x + 0.25, SEE = 2.9 ml). The mean difference between LVSV and RVSV by ACM was -1.25 (2.76) ml. The Qp/Qs ratio obtained by ACM in the control group was 0.98 (0.06). The Qp/Qs ratio in patients with an atrial septal defect was significantly higher than in the control group (3.11 (1.20), p < 0.001). ACM determination of the Qp/Qs ratio correlated well with oximetry determination (r = 0.86, y = 0.75x + 0.55, SEE = 0.64). The mean difference between ACM and oximetry for the measurement of the Qp/Qs ratio was -0.28 (0.69). CONCLUSIONS: The newly developed ACM method is clinically useful for non-invasive automated estimations of the Qp/Qs ratio in patients with an atrial septal defect.

Adult↗

New applications of intracardiac echocardiography: assessment of coronary blood flow by colour and pulsed Doppler imaging in dogs.

OBJECTIVE: To explore the application of a new 10 French intracardiac echocardiography (ICE) catheter with phased array and Doppler capable transducer for the assessment of epicardial and intramyocardial coronary blood flow. METHODS: The coronary arteries were detected by cross sectional imaging in seven closed chest dogs, and coronary blood flow visualised by colour Doppler. Blood flow velocities were recorded by pulsed Doppler at baseline for reproducibility of repeated measurements, and during hyperaemia for coronary flow reserve measurements. Comparisons were made with Doppler guide wire data obtained simultaneously. Intramyocardial coronary artery blood flow was assessed by colour flow mapping, and the blood flow velocities recorded using pulsed Doppler at baseline and during hyperaemia. RESULTS: Seven left main, six left anterior descending, seven left circumflex, and five right coronary arteries were visualised in the seven animals by cross sectional or colour Doppler imaging. Repeated measurements of coronary flow velocity showed a good correlation (mean diastolic velocity, r = 0.93, n = 22, p < 0.0001; peak diastolic velocity, r = 0.96, n = 22, p < 0.0001, respectively). Intraobserver/interobserver variability was satisfactorily low. Coronary flow reserve from ICE correlated highly with the value obtained from the Doppler guide wire (r = 0.90, n = 26, p < 0.0001). Intramyocardial coronary blood flow was identified in all seven dogs, and flow velocities were recorded at baseline and during hyperaemia in four animals. CONCLUSIONS: This new ICE catheter provides high quality diagnostic resolution. It is useful for coronary blood flow assessment.

Animals↗

Changes in transmural distribution of myocardial perfusion assessed by quantitative intravenous myocardial contrast echocardiography in humans.

OBJECTIVE: To clarify whether changes in transmural distribution of myocardial perfusion under significant coronary artery stenosis can be assessed by quantitative intravenous myocardial contrast echocardiography (MCE) in humans. METHODS: 31 patients underwent dipyridamole stress MCE and quantitative coronary angiography. Intravenous MCE was performed by continuous infusion of Levovist. Images were obtained from the apical four chamber view with alternating pulsing intervals both at rest and after dipyridamole infusion. Images were analysed offline by placing regions of interest over both endocardial and epicardial sides of the mid-septum. The background subtracted intensity versus pulsing interval plots were fitted to an exponential function, y = A (1 - e(-betat)), where A is plateau level and beta is rate of rise. RESULTS: Of the 31 patients, 16 had significant stenosis (> 70%) in the left anterior descending artery (group A) and 15 did not (group B). At rest, there were no differences in the A endocardial to epicardial ratio (A-EER) and beta-EER between the two groups (mean (SD) 1.2 (0.6) v 1.2 (0.8) and 1.2 (0.7) v 1.1 (0.6), respectively, NS). During hyperaemia, beta-EER in group A was significantly lower than that in group B (1.0 (0.5) v 1.4 (0.5), p < 0.05) and A-EER did not differ between the two groups (1.0 (0.5) v 1.2 (0.4), NS). CONCLUSIONS: Changes in transmural distribution of myocardial perfusion under significant coronary artery stenosis can be assessed by quantitative intravenous MCE in humans.

Contrast Media↗

Automated quantification of aortic regurgitant volume and regurgitant fraction using the digital colour Doppler velocity profile integration method in patients with aortic regurgitation.

BACKGROUND: The recently introduced automated cardiac flow measurement (ACM) technique provides a quick and an accurate automated calculation of stroke volume and cardiac output. This is obtained by spatio-temporal integration of digital Doppler velocity profile data. OBJECTIVE: To evaluate the use of the ACM method in the non-invasive assessment of aortic regurgitant volume and per cent regurgitant fraction (%RF) in patients with aortic regurgitation. METHODS: Aortic outflow volume and mitral inflow volume were calculated by the ACM method in 22 patients with isolated aortic regurgitation. Aortic regurgitant volume and %RF were calculated using the following equations: aortic regurgitant volume = [aortic outflow volume] - [mitral inflow volume]; %RF = [aortic regurgitant volume]/[aortic outflow volume] x 100. The results were compared with those obtained using pulsed Doppler cross sectional echocardiography (PD-2D). RESULTS: Aortic regurgitant volumes measured by the ACM method showed a good correlation with the PD-2D measurements (r = 0.95, y = 0.9x + 3.9, SEE = 8.6 ml); the mean (SD) difference between the two methods was -1.5 (8.5) ml. %RF estimated by the ACM method also correlated well with the values obtained by the PD-2D method (r = 0.91, y = 0.9x + 4.9, SEE = 6.0%); the mean difference between the two methods was -1.5 (6.0)%. Total time required for aortic regurgitant volume (for one cardiac cycle) by the ACM method was significantly shorter than by the PD-2D method (130 (16) v 230 (32) s, p < 0.01). CONCLUSIONS: The newly developed the ACM method is quick and accurate in the automated assessment of aortic regurgitant volume and per cent regurgitant fraction in patients with isolated aortic regurgitation.

Adult↗

Involvement of vascular endothelial growth factor in exercise induced bronchoconstriction in asthmatic patients.

BACKGROUND: There is evidence that the bronchial microcirculation has the potential to contribute to the pathophysiological mechanisms of exercise induced bronchoconstriction (EIB) in asthmatic subjects. Vascular endothelial growth factor (VEGF), which is highly expressed in asthmatic airways, increases vascular permeability. The relationship between VEGF levels in induced sputum and the severity of EIB in asthmatic subjects was studied. METHODS: The concentration of VEGF in induced sputum was examined in 23 asthmatic subjects and 11 normal controls. The asthmatic subjects performed an exercise test and the % maximal fall in forced expiratory volume in 1 second (FEV(1)) was measured. Beclomethasone dipropionate (BDP) 400 micro g twice daily was administered to the asthmatic subjects for 8 weeks and the exercise test and sputum induction were repeated. RESULTS: The concentration of VEGF in induced sputum was significantly higher in asthmatic subjects than in normal controls. There was a significant correlation between the concentration of VEGF and the % maximal fall in FEV(1) (r=0.826, p=0.0001) and between the concentration of VEGF and airway vascular permeability index (r=0.621, p=0.0037). After treatment with inhaled BDP there was a significant decrease in the concentration of VEGF in the asthmatic subjects (before treatment: 7051 (2361) pg/ml, after treatment: 4498 (2135) pg/ml, p<0.0001). The change in the concentration of VEGF was significantly correlated with the change in the % maximal fall in FEV(1) (r=0.463, p=0.031). CONCLUSIONS: Excessive production of VEGF in asthmatic airways may contribute to the pathogenesis of EIB via increased airway vascular permeability.

Administration, Inhalation↗

Decreased peroxynitrite inhibitory activity in induced sputum in patients with bronchial asthma.

BACKGROUND: The production of peroxynitrite, an extremely potent oxidant, is increased in inflammatory lung disease. It is therefore important to measure antioxidant activity against peroxynitrite in epithelial lining fluid to examine the physiological effects of peroxynitrite in the airways of patients with asthma. This study was designed to determine whether peroxynitrite inhibitory activity in induced sputum is correlated with clinical characteristics and airway inflammatory indices in asthmatic patients. METHODS: Inflammatory indices were measured in induced sputum from 25 patients with asthma and 12 normal control subjects. Peroxynitrite inhibitory activity was also measured by monitoring rhodamine formation in sputum samples. RESULTS: Peroxynitrite inhibitory activity in induced sputum was significantly lower in asthmatic patients (52.4 (24.5)%) than in normal control subjects (92.1 (3.9)%, p<0.0001). Its activity was significantly correlated with forced expiratory volume in 1 second (FEV(1)) % predicted (r=0.774, p<0.0001) and bronchial hyperreactivity to methacholine (r=0.464, p=0.023). There was a significant negative correlation between peroxynitrite inhibitory activity and the degree of eosinophilic airway inflammation (% eosinophils, r=-0.758, p<0.0001; eosinophil cationic protein, r=-0.780, p<0.0001). CONCLUSIONS: Decreased peroxynitrite inhibitory activity occurs in induced sputum of asthmatic patients. Since even in patients with stable asthma the airway lining fluid lacks peroxynitrite inhibitory activity, large amounts of peroxynitrite, which are further increased during an acute asthma attack, would not be completely inactivated and asthmatic airways might have markedly increased susceptibility to peroxynitrite induced airway injury.

Adult↗

Acute effects of passive smoking on the coronary circulation in healthy young adults.

CONTEXT: Recent studies have shown that passive smoking is a risk factor for ischemic heart disease and may be associated with vascular endothelial dysfunction. The acute effects of passive smoking on coronary circulation in nonsmokers are not known. OBJECTIVE: To determine the acute effects of passive smoking on coronary circulation using coronary flow velocity reserve (CFVR), assessed by noninvasive transthoracic Doppler echocardiography. DESIGN, SETTING, AND PARTICIPANTS: Cross-sectional study conducted from September 2000 to November 2000 among 30 Japanese men (mean age, 27 years; 15 healthy nonsmokers and 15 asymptomatic active smokers) without history of hypertension, diabetes mellitus, or hyperlipidemia. MAIN OUTCOME MEASURES: Coronary flow velocity reserve, calculated as the ratio of hyperemic to basal coronary flow velocity induced by intravenous infusion of adenosine triphosphate and measured in each participant before and after a 30-minute exposure to environmental tobacco smoke. RESULTS: Heart rate and blood pressure responses to adenosine triphosphate infusion were not affected by passive smoking exposure in either group. Passive smoking exposure had no effect on basal coronary flow velocity in either group. Mean (SD) CFVR in nonsmokers was significantly higher than that in active smokers before passive smoking exposure (4.4 [0.91] vs 3.6 [0.88], respectively; P =.02), while CFVR after passive smoking exposure did not differ between groups (P =.83). Passive smoking exposure significantly reduced mean (SD) CFVR in nonsmokers (4.4 [0.91] vs 3.4 [0.73], respectively; P<.001). CONCLUSIONS: Passive smoking substantially reduced CFVR in healthy nonsmokers. This finding provides direct evidence that passive smoking may cause endothelial dysfunction of the coronary circulation in nonsmokers.

Adenosine Triphosphate↗

Simple detection of severe coronary stenosis using transthoracic Doppler echocardiography at rest.

Coronary flow velocity can be measured by transthoracic Doppler echocardiography (TTDE). The purpose of this study was to detect severe coronary stenosis using the diastolic-to-systolic flow velocity ratio (DSVR) determined by TTDE at rest. We prospectively examined 190 consecutive patients with angina pectoris for whom coronary angiography was planned. Doppler spectral tracings of flow velocity in the distal left anterior descending artery were recorded by TTDE at rest. The mean and peak DSVR values were computed using mean and peak coronary flow velocities. DSVR measurement by TTDE at rest was performed within 24 hours before angiography, and in patients who underwent coronary intervention it was performed again within 48 hours after the intervention. The success rate for DSVR measurement by TTDE was 83.7%. There were significant differences in peak DSVR and mean DSVR between the patients with severe stenosis (percent diameter stenosis >85%) and those without severe stenosis (1.3 +/- 0.4 vs 1.9 +/- 0.50 and 1.2 +/- 0.4 vs 1.8 +/- 0.5, respectively; p <0.0001). In the 17 patients with successful intervention, DSVR was significantly increased after the procedure (mean 1.2 +/- 0.1 vs 2.0 +/- 0.2; peak 1.2 +/- 0.2 vs 2.0 +/- 0.3, respectively; p <0.0001). For percent diameter stenosis >85%, the best cut-off points were 1.6 for peak DSVR (sensitivity 79.0%, specificity 75.7%) and 1.5 for mean DSVR (sensitivity 77.0%, specificity 77.9%). Thus, DSVR measurement by TTDE is a simple, noninvasive method for detection of severe coronary stenosis at rest.

Adult↗

Elevated levels of oxidized low density lipoprotein show a positive relationship with the severity of acute coronary syndromes.

BACKGROUND: There is accumulating data that acute coronary syndromes relate to recent onset activation of inflammation affecting atherosclerotic plaques. Increased blood levels of oxidized low density lipoprotein (ox-LDL) could play a role in these circumstances. METHODS AND RESULTS: Ox-LDL levels were measured in 135 patients with acute myocardial infarction (AMI; n=45), unstable angina pectoris (UAP; n=45), and stable angina pectoris (SAP; n=45) and in 46 control subjects using a sandwich ELISA method. In addition, 33 atherectomy specimens obtained from a different cohort of patients with SAP (n=10) and UAP (n=23) were studied immunohistochemically for ox-LDL. In AMI patients, ox-LDL levels were significantly higher than in patients with UAP (P<0.0005) or SAP (P<0.0001) or in controls (P<0.0001) (AMI, 1.95+/-1.42 ng/5 microgram LDL protein; UAP, 1.19+/-0.74 ng/5 microgram LDL protein; SAP, 0.89+/-0.48 ng/5 microgram LDL protein; control, 0.58+/-0.23 ng/5 microgram LDL protein). Serum levels of total, HDL, and LDL cholesterol did not differ among these patient groups. In the atherectomy specimens, the surface area containing ox-LDL-positive macrophages was significantly higher in patients with UAP than in those with SAP (P<0.0001). CONCLUSIONS: This study demonstrates that ox-LDL levels show a significant positive correlation with the severity of acute coronary syndromes and that the more severe lesions also contain a significantly higher percentage of ox-LDL-positive macrophages. These observations suggest that increased levels of ox-LDL relate to plaque instability in human coronary atherosclerotic lesions.

Angina Pectoris↗