Publications and source records attributed to J Zoetelief.

At least 19 recordsLinked to original sources

Response to 'Patient dose measurements in radiological practices'.

A lack of suitable dosimetric quantities for application in diagnostic radiology is noted by Dr Moores. It is concluded by Dr Moores that it is not possible to adhere to the basic principles of the International Commission on Radiation Units and Measurements (ICRU) regarding patient dosimetry in diagnostic radiology due to the extremely wide variety of quantities and units employed. The conclusion of the ICRU on similar observations, however, was that there is a need for harmonization of quantities and terminology for dosimetry in diagnostic and interventional radiology and they established a Report Committee with the aim of formulating an ICRU report on 'dosimetric procedures in diagnostic radiology'. The report produced by this committee entitled 'Patient dosimetry for x rays used in medical imaging' was accepted for publication in December 2005 and is currently at press, and may serve to improve the current situation with regard to patient dose measurement in diagnostic and interventional radiology.

Calibration↗

Glandularity and mean glandular dose determined for individual women at four regional breast cancer screening units in the Netherlands.

The nationwide breast cancer screening programme using mammography has been in full operation in The Netherlands since 1997. There is concern that the mean glandular doses due to mammography might be differing between different regions of the country due to differences in glandularity and compressed breast thickness. To investigate regional differences, glandularity, compressed breast thickness and mean glandular dose were determined for individual breasts during screening at mammography units at four locations in The Netherlands. Differences in glandularity were observed, which could be related qualitatively to differences in age of the participants at the different locations. Mean glandular dose depends on compressed breast thickness, glandularity and technical conditions of screening. The lowest average value of the mean glandular dose was found for the unit in Amsterdam. This is most likely due to the use of the Mo/Rh anode/filter combination at this unit, in addition to the Mo/Mo combination. At the other three units, almost exclusively the Mo/Mo anode/filter combination was used. Differences in mean glandular dose averaged per unit could be related mainly to differences in tube-current exposure-time product values. Consequently, it is concluded that differences in mean glandular dose at different units are marginal.

Aged↗

Estimating effective dose for a cardiac catheterisation procedure with single or double personal dosemeters.

In most countries of the European Union legislation requires individual determination and registration of the dose to radiological workers exposed to ionising radiation to check whether dose limits are exceeded. To assess stochastic risk, ideally effective dose (E) should be known. In practice, personal dose equivalent [H(P)(10)] is used as it can be measured with a personal dosemeter. The dosemeter reading may provide a reasonable assessment of H(P)(10), but it may deviate strongly from E, in particular in radiology procedures for medical diagnosis or intervention when protective clothing like lead-equivalent apron and thyroid collar is worn. In the literature various correction factors and algorithms to convert readings of single or dual dosemeters to an estimate of E can be found. An illustrative example of a cardiac catheterisation procedure, in which dose calculations are made by Monte Carlo simulation of radiation transport, shows that such corrections may still yield considerable overestimation.

Cardiac Catheterization↗

Assessment of induction of secondary tumours due to various radiotherapy modalities.

One of the objectives of the European Sixth Framework integrated project MAESTRO is to perform an assessment of risk due to various radiotherapy modalities, regarding secondary tumour induction. Initially, the study will focus on cancer of the prostate and the present work represents the first step towards that goal. One of the intended tools, to be used in the assessment, is the Monte Carlo radiation transport code ORANGE. A validation of the ORANGE code's capability to tally dose on a grid superimposed on an existing MCNP geometry is given. Preliminary results on the dose distribution due to conventional radiotherapy treatment of prostate cancer are discussed. Two mathematical models of the patient are proposed and the clinical relevance of the ADAM phantom is investigated. A problem in comparing average doses provided by commercial treatment planning systems and those calculated with Monte Carlo is noticed. The two proposed models are shown to receive a lower dose and average energy deposition than a 'real' patient.

Algorithms↗

The ICRU (International Commission on Radiation Units and Measurements): its contribution to dosimetry in diagnostic and interventional radiology.

The ICRU (International Commission on Radiation Units and Measurements was created to develop a coherent system of quantities and units, universally accepted in all fields where ionizing radiation is used. Although the accuracy of dose or kerma may be low for most radiological applications, the quantity which is measured must be clearly specified. Radiological dosimetry instruments are generally calibrated free-in-air in terms of air kerma. However, to estimate the probability of harm at low dose, the mean absorbed dose for organs is used. In contrast, at high doses, the likelihood of harm is related to the absorbed dose at the site receiving the highest dose. Therefore, to assess the risk of deterministic and stochastic effects, a detailed knowledge of absorbed dose distribution, organ doses, patient age and gender is required. For interventional radiology, where the avoidance of deterministic effects becomes important, dose conversion coefficients are generally not yet developed.

Calibration↗

Optimisation strategies and justification: an example in uterine artery embolisation for fibroids.

Radiation risk has to be justified and optimised. This study discusses the radiation risk of uterine artery embolisation (UAE) for the treatment of fibroids. A total of 70 consecutive UAE dosimetry parameters were assessed. Using Monte Carlo simulation, organ and effective doses and dose conversion coefficients (DCCs) (mSv Gy cm(-2)) were calculated. During UAE optimisation, avoidance of oblique views and use of last-image-hold (LIH) documentation instead of digital subtraction angiography (DSA) were investigated. Mean dose-area product (DAP) was 37.1 Gy cm2 (median 23.7 Gy cm2) and mean fluoroscopy time was 18.4 min (median 16.6 min). Dose values decreased as the study progressed: mean DAP for patients 1-21, 68.5 Gy cm2; patients 22-43, 35.7 Gy cm2; and patients 44-69, 13.0 Gy cm2. Average DCC for DSA image procedures was 0.572, yielding a mean effective dose of 29.6 mSv (median 17.1 mSv). For LIH-only procedures, an average DCC of 0.813 was estimated [using mean effective dose: 10.6 mSv (median 8.1 mSv)].

Adult↗

Investigation of possible methods for equipment self-tests in digital radiology.

Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests.

Computer-Aided Design↗

Quality control of equipment used in digital and interventional radiology.

Digital and interventional radiology are increasingly important areas of radiology. Quality control (QC) of such equipment is of particular importance to avoid unnecessary high doses and to help to achieve good image quality. Within the DIMOND III project, equipment requirements and specifications for digital and interventional radiology have been formulated. A protocol for QC tests has been drafted based on various national and international recommendations. Tests are included for various parts of the imaging chain, i.e. X-ray tube and generator, X-ray tube control system, laser printer and display station, and image quality and patient dose. Preliminary tolerance levels have been set for the various tests, after initial measurements. To check the suitability of QC tests and stated tolerance levels, measurements were made at the University Hospital Gasthuisberg in Leuven for equipment used for paediatric radiology and a unit used for chest examinations. The results of the various tests are reported.

Humans↗

Dose conversion coefficients for interventional procedures.

Effective dose (E) is a convenient quantity to estimate the stochastic risk of radiation applied to patients in interventional procedures and can be used for optimisation. Relatively long exposure times may cause deterministic effects. Hence it is necessary to know the (maximum local) doses in organs owing to the interventional procedure. In practice, organ doses cannot be measured directly. They are derived by applying a conversion coefficient to a measurable quantity, e.g. dose-area product (DAP) or entrance skin dose. For a number of interventional procedures, dose conversion coefficients (DCCs) can be found in the literature. Various DCCs are stated for nominally equal procedures, e.g. for percutaneous transluminal coronary angioplasty both 0.18 and 0.27 mSv Gy(-1) cm(-2) were reported to convert DAP to effective dose. Dependence of DCC on protocol and equipment parameters, as demonstrated through Monte Carlo simulation in this paper, makes it hazardous to simply adopt a literature value.

Arteries↗

Dose constraints and guidance for exposure of individuals knowingly and willingly helping in the support and comfort of individuals undergoing medical exposure.

The council of the European Union (EU) has adopted directive 97/43/EURATOM that states that Member States shall ensure that dose constraints are established for exposure of those individuals (voluntary helpers) knowingly and willingly helping patients undergoing medical diagnosis or treatment. This study investigates for which medical diagnoses and treatments voluntary helpers are active. It provides a rough estimation of the effective dose to the voluntary helper for various applications. It summarises the dose constraints established in various EU Member States. Voluntary helpers are especially active in paediatric radiology and in nuclear medicine for both diagnostic and for therapeutic purposes. No voluntary helpers are active during radiotherapy. Voluntary helpers are commonly one of the parents, relatives or friends of the patient. In The Netherlands, the highest effective dose to voluntary helpers of approximately 2.3 mSv is found for therapy of patients younger than 1 y with metaiodobenzylguanidine labelled with 131I. Effective doses to voluntary helpers in paediatric radiology are, generally, quite small, i.e. lower than several tens of microSv at maximum without wearing protective clothing.

Body Burden↗

Method for determination of the mean fraction of glandular tissue in individual female breasts using mammography.

The nationwide breast cancer screening programme using mammography has been in full operation in the Netherlands since 1997. Quality control of the screening programme has been assigned to the National Expert and Training Centre for Breast Cancer Screening. Limits are set to the mean glandular dose and the centre monitors these for all facilities engaged in the screening programme. This procedure is restricted to the determination of the entrance dose on a 5 cm thick polymethylmethacrylate (PMMA) phantom. The mean glandular dose for a compressed breast is estimated from these data. Individual breasts may deviate largely from this 5 cm PMMA breast model. Not only may the compressed breast size vary from 2 to 10 cm, but breast composition varies also. The mean glandular dose is dependent on the fraction of glandular tissue (glandularity) of the breast. To estimate the risk related to individual mammograms requires the development of a method for determination of the glandularity of individual breasts. A method has been developed to derive the glandularity using the attenuation of mammography x-rays in the breast. The method was applied to a series of mammograms at a screening unit. The results, i.e., a glandularity of 93% within the range of 0 to 1, were comparable with data in the literature. The glandularity as a function of compressed breast thickness is similar to results from other investigators using differing methods.

Breast↗

Calculation of absorbed dose around a facility for disposing of low activity natural radioactive waste (C3-dump).

A C3-dump is a facility for disposing of low activity natural radioactive waste containing the uranium series 238U, the thorium series 232Th and 40K. Only the external radiation owing to gamma rays, X-rays and annihilation photons is considered in this study. For two situations--the semi-infinite slab and the tourist geometry--the conversion coefficients from specific activity to air kerma rate at 1 m above the relevant level are calculated. In the first situation the waste material is in contact with the air but in the tourist geometry it is covered with a 1.35 m thick layer. For the calculations, the Monte Carlo radiation transport code MCNP is used. The yield and photon energy for each radionuclide are according to the database of Oak Ridge National Laboratory. For the tourist situation, the depth-dose distribution through the covering layer is calculated and extrapolated to determine the exit dose.

Computer Simulation↗

Dose inhomogeneities for photons and neutrons near interfaces.

Perturbations of charged particle equilibrium (CPE) at interfaces of materials of different atomic composition can lead to considerable differences in the energy deposition by photons and neutrons. Specific examples of these interface perturbations are encountered during irradiation of body cavities and soft tissue adjacent to bone or metallic implants and irradiation of cells in monolayer on the bottom of culture dishes. Another example is the build-up of CPE at air-tissue interfaces, referred to in radiotherapy as the skin sparing effect. For photon irradiation excess production of secondary electrons in high-Z materials, such as glass, bone or gold, will induce appreciably higher doses and decreased cell survival compared to the equilibrium situation. The energy dissipation of fast neutrons in biological materials occurs through recoil protons, heavy recoil nuclei and products of nuclear reactions. Owing to the large contribution from recoil protons to the neutron kerma, the hydrogen content of the biological material mainly determines the energy deposition. For neutron irradiation of cells in monolayer, CPE can be established or deliberately avoided by mounting tissue-equivalent plastic or carbon discs in front of the cells, respectively. This approach makes it possible to distinguish the biological effects of the low- and high-LET radiation components.

Animals↗

Patient radiation exposure in uterine artery embolization of leiomyomata: calculation of organ doses and effective dose.

The goal of this study was estimation of patient effective dose from uterine artery embolization of leiomyomata. Parameters and data relevant to patient dose were recorded for 33 consecutive procedures. Using Monte Carlo simulation of radiation transport, organ and effective doses were calculated in detail for a subset of five procedures, to estimate the effective dose for all procedures. Mean dose area product was 59.9, median 23.4, and range 8.8-317.5 Gycm(2). Mean absorbed ovarian dose was calculated as 51 mGy in the five procedures. Using the dose conversion factor estimated from the Monte Carlo simulation for all procedures a mean estimated effective dose of 34 mSv (median 13 mSv, range 5-182 mSv) results, with a tendency to lower values regarding the succession of the procedures. Patients' radiation exposure level is up to twice of that of an abdominal CT examination. Angiographic equipment related dose-reducing features and radiographic technique essentially influence organ doses and effective dose. Consistent application of dose-reducing techniques and awareness of radiation exposure justifies uterine artery embolization as a therapeutic option for the treatment of uterine fibroids.

Adult↗

The effect of equipment set up on patient radiation dose in conventional and CT angiography of the renal arteries.

Patient radiation dose in angiography of the renal arteries was assessed and optimized after installing new radiological equipment. In three separate studies (n=50, 25 and 20) patient exposure was monitored in detail. For the first study default factory settings were used, for the second the number of digital subtraction angiography (DSA) images was halved and the X-ray beam filtering during fluoroscopy was increased, and for the third study filtering during DSA was increased as well. Standard projections were derived and used in Monte Carlo simulations to derive dose conversion coefficients to calculate effective dose from the dose-area product (DAP). Dose conversion coefficients were also calculated for CT angiography (CTA). Using default factory settings on the new angiography system, DAP, number of images and effective dose were much higher than on the replaced unit. For the studies given above, DAP was reduced from 144 Gy cm(2) to 65 Gy cm(2) to 32 Gy cm(2), and effective dose from 22 mSv to 11 mSv to 9.1 mSv, respectively. Effective dose due to CTA was 5.2 mSv. It is concluded that modern angiography systems, resulting in high customer satisfaction, may readily cause much higher patient exposure than older systems. These doses may also be much higher than necessary. Optimization before putting such systems into use is absolutely essential. Internationally accepted recommendations for image quality and technique factors in angiography would be of great help.

Adolescent↗

Monte Carlo calculations for assessment of radiation dose to patients with congenital heart defects and to staff during cardiac catheterizations.

Effective dose is an important quantity in relation to assessment of radiation risk. Organ and effective doses to paediatric patients undergoing diagnostic and therapeutic heart catheterization procedures can be assessed by combining relatively simple measurements, e.g. of dose-area product (DAP), and calculated dose conversion factors (DCF). This also holds for the radiation dose to the hospital staff, e.g. the cardiologist. Monte Carlo (MC) simulation of radiation transport in mathematical anthropomorphic phantoms is used to obtain the DCFs, which strongly depend on beam quality and geometrical parameters. The performance of a dedicated fast MC code (PCXMC) for patient dosimetry is compared with that of a more elaborate general purpose MC code (MCNP). Resulting organ doses sometimes may differ considerably, partly due to phantom differences. While MCNP uses separate male and female mathematical phantoms, PCXMC uses a hermaphrodite. However, both codes yield effective doses that agree rather well, so PCXMC can be used for convenience. The MCNP code is used to calculate the effective dose to the cardiologist exposed to radiation scattered from the patient. Without protective clothing, effective dose per procedure to the cardiologist is at least two orders of magnitude lower than that to the patient. The effectiveness of various types and thickness of protective clothing has been evaluated for one view of one cardiac catheterization. The results of the calculations do not contradict experimental studies from the literature. MC simulation may serve as a useful tool to improve the accuracy of estimating occupational effective dose from personal dose monitors.

Adolescent↗