Cranial vault expansion using transcutaneously activated magnetic implants.

The technique of distraction osteogenesis has not been widely used in the treatment of problems of the head and face because of the need for external fixators. By using magnetic, rather than mechanical, forces to drive bone movement we hope to expand the applications of the technique to include the treatment of cranial vault deformities. Thirty immature rabbits were studied. Twenty-six of the rabbits underwent operations. Each of the 26 had 2 magnets fixed to its skull: one on the left parietal bone and one on the right parietal bone. Incomplete circumferential osteotomies were then performed around each magnet on 13 of the rabbits. A head frame was attached to each animal. Head frames without magnets were placed on 6 of the rabbits (3 with osteotomy, 3 without osteotomy) while 20 of the animals (10 with osteotomy, 10 without osteotomy) had 2 magnets mounted on the frames which were of opposite polarity to those implanted. The remaining 4 rabbits served as nonoperative controls. Six weeks later all of the animals were sacrificed. There were significant differences in the cranial volumes and contours between the groups of animals. Many of the differences were increased by coincident osteotomy. Associated histologic findings are described.

Animals↗

Improved and simplified tissue extraction method for quantitating long-chain acyl-coenzyme A thioesters with picomolar detection using high-performance liquid chromatography.

A method has been developed that permits rapid and easy tissue extraction of long-chain acyl-coenzyme A (acyl-CoA) thioesters with sensitive quantitation by reversed-phase high-performance liquid chromatography (RP-HPLC). Tissue homogenants are extracted using a reserve Bligh-Dyer technique, and long-chain acyl-CoA esters are harvested in the methanolic aqueous phase. Complex lipids and phospholipids are removed in the chloroform-rich organic Bligh-Dyer second phase, and long-chain acyl-CoA compounds are further purified from the methanolic aqueous Bligh-Dyer first phase on C18 extraction columns after removal of the methanol. The eluted and purified acyl-CoA esters are then quantitated by RP-HPLC using heptadecanoyl-CoA as an internal standard resulting in a detector sensitivity of about 12 pmol. Ten long-chain acyl-CoA esters from C12:0 to C20:4 were identified and separated from canine renal cortex and murine liver samples. The predominant acyl-CoA peaks from both kidney and liver were 14:0, 16:1, 16:0, 18:1, 18:2 and 20:4. Murine liver also produced 18:0 and all peaks disappeared after alkaline hydrolysis of the samples. This extraction and quantitation technique can successfully be used for tissue samples as small as 20 mg, and many samples can be processed in a short period of time. The simplicity of the extraction procedure and the sensitivity of the assay make this an attractive alternative approach to quantitating long-chain acyl-CoA thioesters from complex biological samples such as tissues.

Acyl Coenzyme A↗