PubMed Health⌕ Search

Biomedical subjects

J Zweit

Publications and source records attributed to J Zweit.

At least 19 recordsLinked to original sources

Microfluidic reactor for the radiosynthesis of PET radiotracers.

Here we show the first application of a microfabricated reaction system to PET radiochemistry, we term "microfluidic PET". The short half-life of the positron emitting isotopes and the trace chemical quantities used in radiolabelling make PET radiochemistry amenable to miniaturisation. Microfluidic technologies are capable of controlling and transferring tiny quantities of liquids which allow chemical and biochemical assays to be integrated and carried out on a small scale. Such technologies provide distinct advantages over current methods of PET radiochemical synthesis. To demonstrate "proof of principle" we have investigated the radiohalogenation of small and large molecular weight molecules using the microfluidic device. These reactions involved the direct radioiodination of the apoptosis marker Annexin V using iodine-124, the indirect radioiodination of the anti-cancer drug doxorubicin from a tin-butyl precursor and the radiosynthesis of 2-[(18)F]FDG from a mannose triflate precursor and fluorine-18 and hence provide a test bed for microfluidic reactions. We demonstrate the rapid radioiodination of the protein Annexin V (40% radiochemical yield within 1 min) and the rapid radiofluorination of 2-[(18)F]FDG (60% radiochemical yield within 4s) using a polymer microreactor chip. Chromatographic analysis showed that the labelling efficiency of the unoptimised microfluidic chip is comparable to conventional PET radiolabelling reactions.

Bioreactors↗

Analysis of metal radioisotope impurities generated in [(18)O]H(2)O during the cyclotron production of fluorine-18.

We show the separation of metal radioisotope impurities using capillary electrophoresis (CE). The methodology used is an improvement of existent protocols for separation of stable metal ions. Production of fluorine-18 using [(18)O]H(2)O-enriched water encased in a titanium target body results in the production of several metal radioisotope impurities. Optimisation of the conditions for CE separation of the metal radioisotope impurities incorporated the use of 6 mM 18-Crown-6 in combination with 12 mM glycolic acid as complexing agents within the running buffer (10 mM pyridine, pH 4.0). Using this optimised procedure, we were able to separate and detect a number of metal radioisotopes, including chromium, cobalt, manganese, vanadium and berillium, within the fM concentration range.

Cyclotrons↗

Microfluidic technology for PET radiochemistry.

This paper describes the first application of a microfabricated reaction system to positron emission tomography (PET) radiochemistry. We have applied microfluidic technology to synthesise PET radiopharmaceuticals using (18)F and (124)I as labels for fluorodeoxyglucose (FDG) and Annexin-V, respectively. These reactions involved established methods of nucleophilic substitution on a mannose triflate precursor and direct iodination of the protein using iodogen as an oxidant. This has demonstrated a proof of principle of using microfluidic technology to radiochemical reactions involving low and high molecular weight compounds. Using microfluidic reactions, [(18)F]FDG was synthesised with a 50% incorporation of the available F-18 radioactivity in a very short time of 4s. The radiolabelling efficiency of (124)I Annexin-V was 40% after 1 min reaction time. Chromatographic analysis showed that such reaction yields are comparable to conventional methods, but in a much shorter time. The yields can be further improved with more optimisation of the microfluidic device itself and its fluid mixing profiles. This demonstrates the potential for this technology to have an impact on rapid and simpler radiopharmaceutical synthesis using short and medium half-life radionuclides.

Biotechnology↗

Performance of a block detector PET scanner in imaging non-pure positron emitters--modelling and experimental validation with 124I.

The key performance measures of resolution, count rate, sensitivity and scatter fraction are predicted for a dedicated BGO block detector patient PET scanner (GE Advance) in 2D mode for imaging with the non-pure positron-emitting radionuclides 124I, 55Co, 61Cu, 62Cu, 64Cu and 76Br. Model calculations including parameters of the scanner, decay characteristics of the radionuclides and measured parameters in imaging the pure positron-emitter 18F are used to predict performance according to the National Electrical Manufacturers Association (NEMA) NU 2-1994 criteria. Predictions are tested with measurements made using 124I and show that, in comparison with 18F, resolution degrades by 1.2 mm radially and tangentially throughout the field-of-view (prediction: 1.2 mm), count-rate performance reduces considerably and in close accordance with calculations, sensitivity decreases to 23.4% of that with 18F (prediction: 22.9%) and measured scatter fraction increases from 10.0% to 14.5% (prediction: 14.7%). Model predictions are expected to be equally accurate for other radionuclides and may be extended to similar scanners. Although performance is worse with 124I than 18F, imaging is not precluded in 2D mode. The viability of 124I imaging and performance in a clinical context compared with 18F is illustrated with images of a patient with recurrent thyroid cancer acquired using both [124I]-sodium iodide and [18F]-2-fluoro-2-deoxyglucose.

Computer Simulation↗

Rapid screening of 2-[18F]-fluoro-2-deoxy-D-glucose infusions for volatile organic compound contaminants by solid phase microextraction with gas chromatography-selective ion monitoring mass spectrometry (SPME-GC-SIMMS).

A method compatible with radioactive samples, capable of detecting trace volatile components in a sample volume of ca. 1cm(3) of 2-[18F]-fluoro-2-deoxy-D-glucose solution is described. The approach, based on solid phase micro-extraction gas chromatography-mass spectrometry with a carboxen/polydimethylsiloxane based fibre, was optimised with respect to extraction time (10 min), extraction temperature (60 degrees C) and phase volume ratio (1). The analysis time, including extraction, was less than 20 min with linear responses for acetonitrile and ethanol over the ranges: 0.09-80 microg cm(-3) (22 degrees C, acetonitrile) and 0.78-79 microg cm(-3) (22 degrees C, ethanol). The detection limits were estimated to be ca. 0.78 microg cm(-3) for ethanol and 0.09 microg cm(-3) for acetonitrile. Stability studies indicated analyte losses of up to 75% over 24h and analysis of aged 2-[18F]FDG samples showed that levels of ethanol and acetonitrile were not less than 100 microg cm(-3), indicative of levels substantially greater than this in the original infusions given to human subjects.

Calibration↗

Continuous angiotensin II infusion increases tumour: normal blood flow ratio in colo-rectal liver metastases.

Insufficient blood flow within colo-rectal hepatic metastases is a factor which may limit drug delivery to, and thus the response of, these tumours to regional chemotherapy. Loco-regional flow may be manipulated pharmacologically to enhance the tumour blood flow relative to that of the normal liver. However, as yet, only transient effects have been studied. Patients receiving regional chemotherapy for unresectable hepatic disease were given a 45 min regional infusion of the vasoconstrictor Angiotensin II. Intrahepatic blood flow distribution was assessed serially by Positron Emission Tomography (PET) imaging together with the trapping tracer copper(II) pyruvaldehyde bis(N-4-methylthiosemicarbazone) (Cu-PTSM) labelled using copper-62. Eleven lesions in nine patients were studied, with no adverse effects. Prior to Angiotensin II administration tumour blood flow was generally found to be greater than that of liver (10/11 lesions; 8/9 patients; median TNR 1.3, iqr 0.9-2.5). A significant increase in relative flow to tumour was seen in response to 10 min Angiotensin II infusion in most cases (7/11 lesions; 7/9 patients; median TNR 2.1, iqr 1.4-4.1; P = 0.008), which appeared to be sustained throughout the 45 min infusion period (median TNR 1.85, iqr 1.3-3.8; P = 0.03). These effects were accompanied by transient elevation of mean arterial pressure, but no change in pulse rate. These observations suggest that prolonged regional vasoconstrictor administration could prove useful in the management of unresectable colo-rectal hepatic metastases, and that further development of vascular manipulation to enhance tumour targeting and drug delivery is warranted.

Angiotensin II↗

62Cu-PTSM and PET used for the assessment of angiotensin II-induced blood flow changes in patients with colorectal liver metastases.

The aim of this study was to establish a quantitative positron emission tomography (PET) method for investigating angiotensin II (AII)-induced changes in blood flow distribution in the liver. This was in order to evaluate the role of vascular manipulation applied to locoregional chemotherapy treatment in patients with colorectal liver metastases. The tracer selected was copper-62 (II) pyruvaldehyde bis-(N4-methyl)thiosemicarbazone (62Cu-PTSM), which exhibits high first-pass extraction and tissue retention following intra-arterial administration. The short half-life of the tracer and its availability from a 62Zn/62Cu generator enabled short-interval repeat PET scans on patients in a single imaging session. Distribution of tracer within the liver was imaged in a single view using a PET camera with rotating large-area detectors. By optimisation of the acquisition protocol, it was possible to acquire sufficient data to produce good-quality images and to quantify tracer uptake with an accuracy of <10%. Reproducibility of the imaging method was assessed in a single patient in whom three consecutive 62Cu-PTSM PET scans were obtained, and in whom no vascular manipulation was performed. Sets of scans (before, during and immediately after a 45-min AII infusion) were obtained in nine patients to assess blood flow changes associated with prolonged vascular manipulation. Significant individual responses, varying in both the magnitude and the duration of flow change, were observed in the majority of cases (7/11 lesions; 7/9 patients). These findings illustrate the potential of 62Cu-PTSM and PET for pharmacological studies. The wide range of individual patient responses to AII infusion suggests that PET blood flow assessment would be of value for selecting patients in whom this procedure may be effective.

Algorithms↗

In-vitro uptake of radioactive lipiodol I-131 and I-125 by hepatoblastoma: implications for targeted radiotherapy.

Lipiodol, a stable iodine addition product of fatty ethyl esters derived from poppyseed oil, has been used as a vehicle for targeted cytotoxic or radiotherapeutic treatment in adults with unresectable hepatocellular carcinoma and in a few children with advanced hepatoblastoma (HB). Prolonged retention of lipiodol by the cancer cells might enable more effective targeted therapy to advanced, multifocal, or metastatic HB. To investigate the uptake and cytotoxic efficacy of beta and Auger electron-emitting radioconjugates on HB cells, monolayers of HB (C3a, Hep Tow1) and normal human hepatocyte cell lines were exposed to lipiodol131 (L131), lipiodol125 (L125), or a cocktail of both isotopes. Uptake of radioactivity was assessed autoradiographically using phosphoimages and the cytotoxicity assessed by trypan blue exclusion and clonogenic assay. The uptake of the different radioconjugates was identical in both HB cell lines. The "cocktail" of both radioactive lipiodols caused the greatest cytotoxicity to HB C3a, and HepTow1. L125 alone had a similar level of uptake and cytotoxicity as L131. Radioactive iodine alone did not show any cytotoxicity on any of the liver cell lines in culture for up to 72 h. These experimental results provide support for a clinical strategy of combinations ("cocktails") of radioconjugates in targeted radiotherapy in patients with HB.

Carcinoma, Hepatocellular↗

Developments in whole-body molecular imaging of live subjects.

New molecular imaging technologies are being developed specifically for imaging animal models of human disease. Positron emission tomography (PET) in particular allows in vivo biochemistry to be studied with a high degree of sensitivity and specificity, and provides direct in vivo information on molecular and cellular pathways that underlie disease mechanisms and therapeutics. However, clinical PET systems have inadequate resolution for imaging small animals. Thus, specialized high-resolution PET hardware and software are now being developed.

Animals↗

Effect of glycation on basic fibroblast growth factor induced angiogenesis and activation of associated signal transduction pathways in vascular endothelial cells: possible relevance to wound healing in diabetes.

Ineffectual wound healing in hyperglycaemic patients suffering from diabetes mellitus is characterised by a reduction in capillary reformation (angiogenesis). Basic fibroblast growth factor (FGF-2) is secreted by fibroblasts, macrophages and in particular endothelial cells (EC) in response to tissue injury and is important in promotion of neovascularisation. Recently, glycation of FGF-2 has been shown to significantly reduce its activity in vitro. We have examined the kinetics of FGF-2 glycation and compared its ability with that of native FGF-2 to activate mitogenesis, capillary formation and associated signal transduction in bovine aortic EC (BAEC). FGF-2 was exposed to 0.25 M glucose-6-phosphate (G-6-P) for 24-72 h and the degree of glycation determined by matrix assisted laser desorption ionisation mass spectrometry. Native FGF-2 was heterogeneous with Mw in the range 15,153.6-17,903 Da. After 24 h incubation with G-6-P there was evidence of glycation, and the mass increase corresponded to addition of 2.7 mol of G-6-P residues; after 48 h, 4 mol sugar was added and this increased to 8.7 after 72 h. Dimerisation of FGF-2 was observed after 72 h of treatment. Induction of mitogenesis in BAEC was significantly reduced by 25%-40% after treatment for 48-96 h with glycated (24 h) FGF-2 (gFGF-2; 100 pg/ml-5 ng/ml; P < 0.05), whilst capillary tubule formation was significantly reduced by between 60% and 90% (100 pg/ml-1 ng/ml; P < 0.05) after 5 days compared to native FGF-2. Subsequent investigation of the signal transduction molecules associated with mitogenesis showed a reduction in FGF-2 induced tyrosine phosphorylated proteins of approximate Mw 20-150 kDa between 10 min and 24 h, in particular, mitogen activated protein kinase (MAPK)/early response kinase (ERK-1, ERK-2), after glycation. To determine the reason for reduced angiogenic activity of gFGF-2, we compared its binding characteristics to that of native FGF-2. Total binding of gFGF-2 to the cell surface was significantly reduced in BAEC analysed by FACS compared to native FGF-2 (P < 0.05). Further investigation using 125I-labelled differentially washed samples, demonstrated a significant reduction in gFGF-2 binding to the high affinity tyrosine kinase receptor (46%) compared to native FGF-2. In summary, glycation of FGF-2 in vitro occurs rapidly within 24 h in the presence of elevated levels of G-6-P. Glycation caused a significant reduction in the ability of FGF-2 to bind to the tyrosine kinase receptor and activate signal transduction pathways responsible for both mitogenesis and capillary formation in BAEC. These results could help to explain the mechanism behind impaired wound healing in patients with diabetes mellitus.

Animals↗

Immuno-PET of human colon xenograft- bearing BALB/c nude mice using 124I-CDR-grafted humanized A33 monoclonal antibody.

UNLABELLED: Radiolabeling monoclonal antibodies (mAbs) allows the evaluation of biodistribution of constructs in vivo through gamma camera imaging and also permits quantitation of mAb uptake in tumors through biopsy-based counting techniques. The quantitation of radiolabeled mAb uptake in cancer patients is complicated by the attenuation of gamma emissions of routinely used isotopes (e.g., 131I and 111In) and the spatial resolution and sensitivity of gamma cameras. METHODS: We used the positron-emitting isotope 124I (half-life [T1/2] = 4.2 d) to label the recombinant humanized anti-colorectal cancer A33 antibody (huA33) and evaluated its biodistribution properties and PET imaging characteristics in BALB/c nude mice bearing SW1222 colorectal xenografts and control colon tumors. RESULTS: The immunoreactivity of radioconjugate was 78% as determined using the cell-binding Lindmo assay. The apparent association constant was found to be 2.2 x 10(9) M(-1), and the number of antibody binding sites per cell was 371,000. The radioconjugate was found to be stable in serum obtained from mice at various times after injection. Assuming a two-compartment model with a four-parameter fit of mean blood levels, the T1/2alpha was 1.5 h and the T1/2beta was 38.2 h. Excellent tumor uptake was obtained, with maximal uptake reaching 50.0 +/- 7.0 percentage injected dose per gram of tumor by 4 d after injection. Specificity of localization was shown by lack of uptake in control tumor. PET imaging detected antigen-positive tumor by 4 h after injection, and high-resolution images were obtained by 24 h after injection. CONCLUSION: In clinical trials using PET, huA33 labeled with 124I has potential for imaging and staging colon tumors and quantifying antibody uptake in colon tumors in vivo.

Animals↗

Copper bis(diphosphine) complexes: radiopharmaceuticals for the detection of multi-drug resistance in tumours by PET.

Experience with imaging of the multi-drug resistance (MDR) phenotype in tumours using technetium-99m sestamibi, a substrate of the P-glycoprotein (Pgp) transporter, suggests that better quantification of images and separation of MDR from other variables affecting tracer uptake in tumours are required. One approach to these problems is the development of short half-life positron-emitting tracers which are substrates of Pgp. Several lipophilic cationic copper(I) bis(diphosphine) complexes labelled with copper-64 have been synthesised and evaluated in vitro as substrates for Pgp. The synthesis is rapid and efficient with no need for purification steps. The chemistry is suitable for use with very short half-life radionuclides such as copper-62 (9.7 min) and copper-60 (23.7 min). Incubation of the complexes with human serum in vitro showed that they are sufficiently stable in serum to support clinical imaging, and the more lipophilic members of the series are taken up rapidly by cells (Chinese hamster ovary and human ovarian carcinoma) in vitro with great avidity. Uptake in human ovarian carcinoma cells is significantly reduced after several months of conditioning in the presence of doxorubicin, which induces increased Pgp expression. Uptake in hooded rat sarcoma (HSN) cells, which express Pgp, is significantly increased in the presence of the MDR modulator cyclosporin A. Biodistribution studies in hooded rats show rapid blood clearance, excretion through both kidneys and liver, and low uptake in other tissues. The one complex investigated in HSN tumour-bearing rats showed uptake in tumour increasing up to 30 min p.i. while it was decreasing in other tissues. We conclude that diphosphine ligands offer a good basis for development of radiopharmaceuticals containing copper radionuclides, and that this series of complexes should undergo further evaluation in vivo as positron emission tomography imaging agents for MDR.

Animals↗

Metal complexes of bleomycin: evaluation of [Rh-105]-bleomycin for use in targeted radiotherapy.

Bleomycin has been used as a carrier for several radioisotopes; however, its potential for clinical use has been limited either by the in vivo stability of the complexes or the half-life of the isotope used. The chemical, biological, and radiological properties of 105Rhodium appear to make it an ideal choice for targeted radiotherapy. The synthesis and purification of a hereto unreported 105Rhodium-bleomycin (105Rh-BLM) complex is described. The stability of this complex in plasma is sufficient to allow targeted delivery of the radioisotope. 57Cobalt-bleomycin was studied under identical conditions for comparative purposes. The suitability of 105Rh-BLM for targeted therapy, which appears to be limited by the renal clearance of this agent, is discussed.

Animals↗

Imaging herpes virus thymidine kinase gene transfer and expression by positron emission tomography.

We report a series of studies that assess the feasibility and sensitivity of imaging of herpes virus type one thymidine kinase (HSV1-tk) gene transfer and expression with [124I]-5-iodo-2'-fluoro-1-beta-D-arabinofuranosyluracil ([124I]-FIAU) and positron emission tomography (PET) and the ability of [124I]-FIAU-PET imaging to discriminate different levels of HSV1-tk gene expression. Studies were performed in rats bearing multiple s.c. tumors derived from W256 rat carcinoma and RG2 rat glioma cells. In the first set, we tested the sensitivity of [124I]-FIAU-PET imaging to detect low levels of HSV1-tk gene expression after retroviral-mediated gene transfer. HSV1-tk gene transduction of one of preestablished wild-type W256 tumor in each animal was accomplished by direct intratumoral injection of retroviral vector-producer cells (W256-->W256TK* tumors). Tumors produced from W256 and W256TK+ cells served as the negative and positive control in each animal. Highly specific images of [124I]-FIAU-derived radioactivity were obtained in W256TK* tumors (that were transduced in vivo) and in W256TK+ tumors but not in nontransduced wild-type W256 tumors. The level of "specific" incorporated radioactivity in transduced portions of both W256TK* and W256TK+ tumors was relatively constant between 4 and 50 h. In the second set, we tested whether [124I]-FIAU and PET imaging can measure and discriminate between different levels of HSV1-tk gene expression. Multiple s.c. tumors were produced from wild-type RG2 cells and stably transduced RG2TK cell lines that express different levels of HSV1-tk. A highly significant relationship between the level of [124I]-FIAU accumulation [% injected dose/g and incorporation constant (Ki)] and an independent measure of HSV1-tk expression (sensitivity of the transduced tumor cells to ganciclovir, IC50) was demonstrated, and the slope of this relationship was defined as a sensitivity index. We have demonstrated for the first time that highly specific noninvasive images of HSV1-tk expression in experimental animal tumors can be obtained using radiolabeled 2'-fluoro-nucleoside [124I]-FIAU and a clinical PET system. The ability to image the location (distribution) of gene expression and the level of expression over time provides new and useful information for monitoring clinical gene therapy protocols in the future.

Animals↗

Design of hypoxia-targeting radiopharmaceuticals: selective uptake of copper-64 complexes in hypoxic cells in vitro.

The well-known perfusion tracer CuPTSM, labelled with 62Cu or 64Cu, is believed to be trapped in cells non-selectively by a bioreductive mechanism. It is proposed that by modifying the ligand to increase its electron donor strength (for example by adding alkyl functionality or replacing sulphur ligands with oxygen ligands), the copper complexes will become less easily reduced and tracers with selectivity for hypoxic tissues could thus be developed. The aim of this work was to prepare 64Cu-labelled complexes of two series of ligands, based on the bis(thiosemicarbazone) (13 ligands) and bis(salicylaldimine) (3 ligands) skeletons, and to evaluate the hypoxia dependence of their uptake in cells. The complexes were incubated with Chinese hamster ovary cells under normoxic and hypoxic conditions, and the cells isolated by centrifugation to determine radioactivity uptake at various time points up to 90 min. Several members of both series demonstrated significant (P<0.05) or highly significant (P<0.01) hypoxia selectivity, indicating that both series of complexes offer a basis for development of hypoxia-targeting radiopharmaceuticals for positron emission tomography (60Cu, 61Cu, 62Cu, 64Cu) and targeted radiotherapy (64Cu, 67Cu).

Animals↗

Thyroid volume measurement in thyrotoxic patients: comparison between ultrasonography and iodine-124 positron emission tomography.

The aim of this paper was to compare ultrasound (US) assessment of thyroid volume with that obtained by positron emission tomography (PET), in patients scheduled for adaptive radioiodine therapy, in which 50 Gy was prescribed to the functional PET volume. Firstly a pilot study was performed to ascertain the optimum method for US assessment of thyroid volume. Then 17 comparative measurements of thyroid volume by US and PET were made on 15 patients (two male and thirteen female, ages 28-73 years) with suspected Graves' disease. This comparison showed that in normal sized and enlarged thyroid glands (n=13), the ratio of functional PET to anatomical US volume was approximately 2:3. However, using the same ellipsoid model, PET and US assessment of anatomical volume agreed within the measurement errors. Owing to the presence of nodules and non-uniform distribution of radioiodine, the functional PET volume and anatomical US volume are often not equivalent. If high-resolution emission tomography (e.g. PET) is unavailable, the comparative data presented in this paper could be used to derive the functional volume from the US volume for calculating functional thyroid dose in hyperthyroid patients undergoing radioiodine therapy.

Algorithms↗

Effect of regional angiotensin II infusion on the relationship between tumour blood flow and fluorouracil uptake in a liver metastasis animal model.

The aim of this study was to assess the relationship between tumour:liver blood flow and 5-fluorouracil (5-FU) uptake ratios in a hypovascular liver metastasis animal model, and examine whether they were similarly affected by a 5 min infusion of angiotension II via the hepatic artery. Tumour:liver blood flow ratio was measured using the isotope tracer 64Copper (II)-pyruvaldehyde bis(n-4 methyl thiosemicarbazone, and 5-FU was tritiated. There was a wide variation in tumour:liver blood flow and 5-FU uptake ratios which could only partly be explained by between animal variation, and was not related either to individual tumour size or overall tumour burden within the liver. There was a close correlation (r = 0.957, P < 0.0001) between tumour:liver blood flow and 5-FU uptake ratios. Angiotensin II infusion significantly increased tumour:liver blood flow (nested analysis of variance, P= 0.05) but not 5-FU uptake (P = 0.29) ratios. There was a poor correlation (r = 0.51, P = 0.13) between tumour:liver blood flow and 5-FU uptake ratios with angiotensin II infusion. Thus, despite an increased 5-FU blood concentration arising from angiotensin-induced reduction in blood flow at constant 5-FU infusion dose, tumour:liver 5-FU uptake ratio did not increase as expected, and there ceased to be a significant correlation between tumour:liver blood flow and 5-FU uptake ratios. We conclude that the vasoactive changes within the hypovascular tumour circulation produced by a 5 min angiotensin II infusion did not significantly increase tumour 5-FU uptake.

Analysis of Variance↗

Copper radionuclides and radiopharmaceuticals in nuclear medicine.

The chemistry, radiochemistry, radiobiology, and radiopharmacology of radiopharmaceuticals containing copper radionuclides are reviewed. Copper radionuclides offer application in positron emission tomography, targeted radiotherapy, and single photon imaging. The chemistry of copper is relatively simple and well-suited to radiopharmaceutical application. Current radiopharmaceuticals include biomolecules labelled via bifunctional chelators primarily based on cyclic polyaminocarboxylates and polyamines, and pyruvaldehyde-bis(N4-methylthiosemicarbazone) (PTSM) and its analogues. The chemistry of copper, of which only a fraction has yet been exploited, is likely to be applied more fully in the future.

Animals↗