Transgenic mice overexpressing human KvLQT1 dominant-negative isoform. Part I: Phenotypic characterisation.

OBJECTIVES: The KCNQ1 gene encodes the KvLQT1 potassium channel, which generates in the human heart the slow component of the cardiac delayed rectifier current, I(Ks). Mutations in KCNQ1 are the most frequent cause of the congenital long QT syndrome. We have previously cloned a cardiac KCNQ1 human isoform, which exerts a strong dominant-negative effect on KvLQT1 channels. We took advantage of this dominant-negative isoform to engineer an in vivo model of KvLQT1 disruption, obtained by overexpressing the dominant-negative subunit under the control of the alpha-myosin heavy chain promoter. RESULTS: Three different transgenic lines demonstrated a phenotype with increasing severity. Functional suppression of KvLQT1 in transgenic mice led to a markedly prolonged QT interval associated with sinus node dysfunction. Transgenic mice also demonstrated atrio-ventricular block leading to occasional Wenckebach phenomenon. The atrio-ventricular block was associated with prolonged AH but normal HV interval in His recordings. Prolonged QT interval correlated with prolonged action potential duration and with reduced K(+) current density in patch-clamp experiments. RNase protection assay revealed remodeling of K(+) channel expression in transgenic mice. CONCLUSIONS: Our transgenic mouse model suggests a role for KvLQT1 channels not only in the mouse cardiac repolarisation but also in the sinus node automaticity and in the propagation of the impulse through the AV node.

Action Potentials↗

Spatial filtering methods for local activation determination in fractionated electrograms from simulated infarcted hearts.

The purpose of this work is the enhancement of local activation in multiphasic extracellular recordings coming from infarcted myocardial tissue and, consequently, the distinction of local from distal activation. Deconvolution procedures are applied, in the form of spatial filtering, in order to estimate transmembrane currents from the extracellular recordings. Simulated data are used in order to test the methods. The current source estimates are compared to the actual transmembrane currents and to Laplacian estimates.

Computer Simulation↗

A comparison of rotating slant hole collimator and rotating camera for single photon emission tomography of the heart.

Measurements were made on the tomographic imaging abilities of a rotating slant hole collimator and a rotating scintillation camera system using a standard heart phantom and thallium-201. This allowed a comparison to be made between these and published results for conventional imaging and the seven pinhole technique under standardised conditions. Although better intraplanar resolutions were obtained with the rotating slant hole, the rotating camera was found to give superior definition of a defect and less propagation between reconstructed sections of the phantom.

Heart↗