Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays.

STATEMENT OF PROBLEM: Onlay preparations are very complex surfaces for computer surface digitization, CAD, and CAM of all-ceramic onlay cores. PURPOSE: This study tested the hypothesis that onlays can be fabricated with CICERO, CEREC, and Procera core technologies. MATERIAL AND METHODS: Fifteen mandibular and 10 maxillary molars were prepared for onlays in 17 patients (11 women and 6 men). The onlay design was experimental. Molars were prepared with deep gingival chamfers in the proximal boxes and around the functional cusps. The nonfunctional cusps were prepared with broad bevels. Eight stone dies of preparations were measured with a laser beam (CICERO), 10 dies with a light beam (CEREC), and 7 dies with a contact probe (Procera). Two onlay cores were produced for the same stone die. One core was used to analyze fit on the stone die, and the other core was porcelain veneered for optimizing anatomy, esthetics, and fit of the onlay and cemented. The fit of the onlay core on the stone die and the cement width on a stone cast were measured by a microscopic digital imaging system. The onlays were evaluated for function every 6 months for 2 years. RESULTS: Measurements of the margins by the CICERO system were (1) precise (error <4%) and (2) accurate with an SD of less than 9 microm. The proposed onlay preparation design met the requirement that all points of the surface be visible from a single point of view for optical 3-dimensional mapping by the CEREC system. For the surface measurements by the Procera contact probe, the orientation of the sapphire tip toward the preparation surface was critical, and it was necessary to apply wax to smooth internal edges. The marginal gaps of the CICERO, CEREC, and Procera cores on the stone dies were 74 microm (SD 15), 85 microm (SD 40), and 68 microm (SD 53), respectively. The cement width was 81 microm (SD 64). No fractures occurred. CONCLUSION: Marginal gaps for the onlay cores were no more than 85 microm. The cement width of the semicomputer-produced onlays of 81 microm was a favorable measurement value for a clinically acceptable, strong all-ceramic onlay. However, this value as well as anatomy and esthetics of the onlay depended on the craftsmanship of the porcelain veneering by the dental technician.

Adult↗

Computer copings for partial coverage.

Partial coverage posterior tooth preparations are very complex surfaces for computer surface digitization, computer design, and manufacture of ceramic copings. The aim of this study was therefore to determine whether the Computer Integrated Crown Reconstruction (Cicero) system was compatible with a proposed partial coverage preparation design and capable of producing ceramic copings. Posterior teeth were prepared for partial coverage copings with deep gingival chamfers in the proximal boxes and around the functional cusps (buccal of mandibular and lingual of maxillary posterior teeth). The nonfunctional cusps (lingual of mandibular and buccal of maxillary posterior teeth) were prepared with broad bevels following the inclined occlusal plane pattern. Optical impressions were taken of stone dies by means of a fast laser-line scanning method that measured the three-dimensional geometry of the partial coverage preparation. Computers digitized the images, and designed and produced the ceramic copings. The Cicero system digitized the partial coverage preparation surfaces precisely with a minor coefficient of variance of 0.2%. The accuracy of the surface digitization, the design, and the computer aided milling showed that the system was capable of producing partial coverage copings with a mean marginal gap of 74 microns. This value was obtained before optimizing the marginal fit by means of porcelain veneering. In summary, Cicero computer technology, i.e., surface digitization, coping design, and manufacture, was compatible with the described partial coverage preparations for posterior teeth.

Bicuspid↗