PubMed Health⌕ Search

Biomedical subjects

János Osán

Publications and source records attributed to János Osán.

3 recordsLinked to original sources

Quantitative determination of low-Z elements in single atmospheric particles on boron substrates by automated scanning electron microscopy-energy-dispersive X-ray spectrometry.

Atmospheric aerosols consist of a complex heterogeneous mixture of particles. Single-particle analysis techniques are known to provide unique information on the size-resolved chemical composition of aerosols. A scanning electron microscope (SEM) combined with a thin-window energy-dispersive X-ray (EDX) detector enables the morphological and elemental analysis of single particles down to 0.1 microm with a detection limit of 1-10 wt %, low-Z elements included. To obtain data statistically representative of the air masses sampled, a computer-controlled procedure can be implemented in order to run hundreds of single-particle analyses (typically 1000-2000) automatically in a relatively short period of time (generally 4-8 h, depending on the setup and on the particle loading). However, automated particle analysis by SEM-EDX raises two practical challenges: the accuracy of the particle recognition and the reliability of the quantitative analysis, especially for micrometer-sized particles with low atomic number contents. Since low-Z analysis is hampered by the use of traditional polycarbonate membranes, an alternate choice of substrate is a prerequisite. In this work, boron is being studied as a promising material for particle microanalysis. As EDX is generally said to probe a volume of approximately 1 microm3, geometry effects arise from the finite size of microparticles. These particle geometry effects must be corrected by means of a robust concentration calculation procedure. Conventional quantitative methods developed for bulk samples generate elemental concentrations considerably in error when applied to microparticles. A new methodology for particle microanalysis, combining the use of boron as the substrate material and a reverse Monte Carlo quantitative program, was tested on standard particles ranging from 0.25 to 10 microm. We demonstrate that the quantitative determination of low-Z elements in microparticles is achievable and that highly accurate results can be obtained using the automatic data processing described here compared to conventional methods.

Journal Article↗

X-ray spectrometry.

Explore the source record for details and available documents.

Electron Probe Microanalysis↗

A Monte Carlo program for quantitative electron-induced X-ray analysis of individual particles.

A versatile Monte Carlo program for quantitative particle analysis in electron probe X-ray microanalysis is presented. The program includes routines for simulating electron-solid interactions in microparticles lying on a flat surface and calculating the generated X-ray signal. Simulation of the whole X-ray spectrum as well as phi(z) curves is possible. The most important facility of the program is the reverse Monte Carlo quantification of the chemical composition of microparticles, including low-Z elements, such as C, N, O, and F. This quantification method is based on the combination of a single scattering Monte Carlo simulation and a robust successive approximation. An iteration procedure is employed; in each iteration step, the Monte Carlo simulation program calculates characteristic X-ray intensities, and a new set of concentration values for chemical elements in the particle is determined. When the simulated X-ray intensities converge to the measured ones, the input values of elemental concentrations used for the simulation are determined as chemical compositions of the particle. This quantification procedure was evaluated by investigating various types of standard particles, and good accuracy of the methodology was demonstrated. A methodology for heterogeneity assessment of single particles is also described.

Journal Article↗