PubMed Health⌕ Search

Biomedical subjects

Jörg Debatin

Publications and source records attributed to Jörg Debatin.

5 recordsLinked to original sources

Unknown primary tumors: detection with dual-modality PET/CT--initial experience.

PURPOSE: To retrospectively evaluate fused positron emission tomography (PET)/computed tomography (CT) in depicting the primary lesion in cancer of an unknown primary tumor, compared with PET, CT, and PET and CT side-by-side evaluation. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained. Forty-five patients (26 men and 19 women) with metastatic cervical adenopathy (n = 18) or extracervical metastases (n = 27) of unknown primary tumor were included. The mean age of the patients was 57 years (range, 29-95 years). PET/CT imaging was performed in all patients 1 hour after administration of 350 MBq of fluorodeoxyglucose with a whole-body field of view. Contrast agents were administered orally and intravenously in all patients to ensure diagnostic CT data. PET/CT data sets were evaluated for the primary tumor, and imaging results were compared with those of CT, PET, and PET and CT side-by-side evaluation. Differences in diagnostic performance were assessed by using the McNemar test with Bonferroni correction, which accounts for multiple comparisons. RESULTS: PET/CT depicted the primary tumor in 15 (33%) of 45 patients. In 30 (67%) patients, the primary tumor site remained occult (P > .05). PET and CT side-by-side evaluation depicted 13 (29%) of 45 tumors (P > .05). PET alone revealed the primary tumor in 11 (24%) of 45 patients (P > .05), while CT alone helped in the correct diagnosis in eight (18%) of 45 patients (P > .05). There were no significant differences between the diagnostic accuracies of PET/CT and the other imaging modalities. CONCLUSION: PET/CT was able to depict more primary tumors, though not significantly, than either of the other imaging modalities, but larger patient cohorts are required to finally judge its value for revealing the primary tumor site.

Adult↗

Acquisition protocol considerations for combined PET/CT imaging.

UNLABELLED: Since its introduction in 1998, dual-modality PET/CT imaging has received great attention in the medical community. For the first time, patients can be examined with both CT and PET in a single examination. A whole-body survey is the standard mode of acquisition. The CT images are used for anatomic reference of the tracer uptake patterns imaged in PET, as well as for attenuation correction of the PET data. The routine use of CT-based attenuation correction and user preferences for the quality and type of the CT examination have led to the introduction of different PET/CT scanning protocols. DISCUSSION: Two general approaches to PET/CT imaging can be distinguished today. One uses CT as a fast transmission source with little additional information for anatomic labeling. The other uses CT as a fast transmission source as well as a state-of-the-art diagnostic tool to maximize image quality using optimal acquisition parameters together with oral and intravenous contrast agents. Variations of these approaches share common concerns about image artifacts that result from mismatches in respiration and patient positioning between the CT and the PET examinations. Protocol requirements for the more complex radiologic PET/CT scenario also include alternative contrast application schemes or modifications to the attenuation correction procedure to handle CT contrast agents appropriately. CONCLUSION: High-quality PET/CT studies can be provided routinely with existing PET/CT technology that is used efficiently by trained and motivated technologists and physicians. Only then will the potential diagnostic benefit of this new imaging modality be explored fully.

Artifacts↗

MR venography using an intravascular contrast agent: results from a multicenter phase 2 study of dosage.

OBJECTIVE: The objective of this study was to determine the optimal dose of the iron oxide contrast agent feruglose for contrast-enhanced MR venography of the abdominopelvic and lower extremity veins and to evaluate its safety and tolerability in patients with deep venous thrombosis. SUBJECTS AND METHODS: We enrolled in our study a total of 45 patients at six centers who had lower extremity deep venous thrombosis documented on radiographic venography. Forty-four patients received the study drug; 39 completed the study. Each patient received three sequential IV injections of feruglose at doses of 0.75, 1.25, and 3.0 mg Fe/kg body weight. MR venography at 1.5 T was repeated at three levels after each dose. Safety was evaluated. RESULTS: The agreement between contrast-enhanced MR venography and radiographic venography with regard to deep venous thrombosis above the knee was zero at the lowest dose (0.75 mg Fe/kg body weight), 43% at the dose 2.0 mg Fe/kg body weight, and 49% at the dose 5.0 mg Fe/kg body weight. No significant difference was seen between the two highest doses. The highest cumulative dose provided the greatest diagnostic usefulness score. No serious adverse events occurred. CONCLUSION: The two highest doses of feruglose showed the best agreement between contrast-enhanced MR venography and radiographic venography for deep venous thrombosis above the knee. The safety and tolerability of feruglose were confirmed.

Adult↗

A multidisciplinary quality management system for the early treatment of severely injured patients: implementation and results in two trauma centers.

OBJECTIVE: The impact of a multidisciplinary quality management system (MQMS) on the early treatment of severely injured patients was tested. DESIGN AND SETTING: Prospective clinical study in two level 1 trauma centers. METHODS AND MATERIALS: MQMS comprised a protocol for documentation, 20 assessment criteria, and the judgement of data by a quality circle. After implementation in Munich (1st period, n=90; 2nd period, n=77) the validation took place in Essen (1st period, n=175; 2nd period, n=150). RESULTS: Improvements in diagnostics were shown by significant time savings in radiological diagnostics and before computed tomography in severe traumatic brain injury. In patients with hemorrhagic shock there was a reduction in time before transfusion (49 to 14 min in Munich; 31 to 22 min in Essen) and before emergency operation (74 to 43 min in Munich; 69 to 45 min in Essen). The time before craniotomy was reduced from 97 to 67 min in Munich. The incidence of delayed diagnosis of life-threatening lesions was diminished from 6% to 3% in Munich (not found in Essen). The TRISS technique showed a reduction in mortality in both hospitals in the second period (Munich: 15.4% TRISS vs. 9.1% observed mortality; Essen: 17.8% vs. 11.3%). CONCLUSIONS: MQMS improved early clinical treatment in severe injury with respect to therapeutic effectiveness and outcome. The effectiveness of the MQMS was shown at two different hospitals

Germany↗

Optimization of contrast dosage for gadobenate dimeglumine-enhanced high-resolution whole-body 3D magnetic resonance angiography.

RATIONALE AND OBJECTIVES: To determine the optimal dose of gadobenate dimeglumine for diagnostic high-resolution whole-body 3D-MR angiography. METHODS: Ten healthy volunteers were examined three times with an ascending dose of Gd-BOPTA (0.1/0.2/0.3 mmol/kg BW). Three-dimensional data sets were collected with a rolling table platform (AngioSURF; MR-Innovation GmbH, Essen, Germany) which integrates the torso surface coil, using a 3D FLASH sequence at five stations from carotid arteries to the trifurcation vessels in 72 seconds. SNR- and contrast-to-noise-values were calculated for 30 segments per patient. For qualitative evaluation a 4-point-visualization scale was used. RESULTS: Overall, significantly (P < 0.05) higher signal-to-noise values and CNR values were determined for Gd-BOPTA at a dose of 0.2 and 0.3 mmol/kg compared with 0.1 mmol/kg. Similarly, the qualitative analysis demonstrated image quality to be superior with 0.2 and 0.3 mmol/kg compared with 0.1 mmol/kg (P < 0.05). Qualitative and quantitative assessment failed to demonstrate a statistically significant difference between 0.2 and 0.3 mmol/kg BW (P > 0.05). CONCLUSION: A dose of 0.2 mmol/kg BW Gd-BOPTA rendered diagnostic image quality in all vascular segments of all volunteers.

Adult↗