Solid-support sample loading for DNA sequencing.

We present a new method for simplified low-quantity DNA loading onto microelectrophoresis devices. The method is based on combined solid-phase extraction, purification, and transport of DNA reversibly bound on paramagnetic microspheres. DNA is adsorbed onto the microspheres, captured with a magnetized permalloy wire, and then directly injected as a highly focused sample plug into the separation channel. This method circumvents both the minimum volume requirement of pipettors (since only solid beads are transported) and the timing complications of double-T microfluidic injection. Injections from Sanger samples of <100 pg total suspended weight match the signal strength of our previous conventional injections at >10-times the starting DNA sample. Sequencing traces show a resolution that matches or exceeds double-T injections. A kinetic model reproduces the time-dependence of the injection signals and proves that total nonidealities in the method produce injection-broadened plugs of approximately 1-s duration. The method should be broadly extendable to DNA and protein separations in both microdevice and capillary electrophoresis.

Base Sequence↗

Reversible ratiometric probe for quantitative DNA measurements.

We have designed a reversible fluorescent DNA probe that can be used to determine the concentration of single-stranded DNA in solution by a ratiometric fluorescence measurement. The probe consists of a single-stranded dual fluorescently labeled DNA molecule that adopts a stem-loop conformation in its nonhybridized state. The stem length and the length of the loop region complementary to the target were chosen to allow for reversible binding. The excitation and emission wavelengths of the two labels Cy3 and Cy5 allow for fluorescence resonance energy transfer in the closed state. Upon hybridization, the probe opens up resulting in a fluorescence intensity increase of the donor and a fluorescence intensity decrease of the acceptor. The ratio of the acceptor-to-donor fluorescence intensities is independent of the amount of probe and provides a quantitative measure of the free target concentration.

Carbocyanines↗

Coupling fiber optics to a permeation liquid membrane for heavy metal sensor development.

We present the first sensing system for metal ions based on the combination of separation/preconcentration by a permeation liquid membrane (PLM) and fluorescence detection with an optical fiber. As a model, a system for the detection of Cu(II) ions was developed. The wall of a polypropylene hollow fiber serves as support for the permeable liquid membrane. The lumen of the fiber contains the strip solution in which Cu(II) is accumulated. Calcein, a fluorochromic dye, acts as stripping agent and at the same time as metal indicator. The quenching of the calcein fluorescence upon metal accumulation in the strip phase is detected with a multimode optical fiber, which is incorporated into the lumen. Fluorescence is excited with a blue LED and detected with a photon counter. Taking advantage of the high selectivity and sensitivity of PLM preconcentration, a detection limit for Cu(II) of approximately 50 nM was achieved. Among five tested heavy metal ions, Pb(II) was the only major interfering species. The incorporation of small silica optical fibers into the polypropylene capillary allows for real-time monitoring of the Cu(II) accumulation process.

Biosensing Techniques↗