Gradient and stimulated echo (GRASTE) imaging.

As a modification of single-shot stimulated echo acquisition mode (STEAM) MRI, a gradient and stimulated echo (GRASTE) sequence is presented that acquires multiple gradient echoes in addition to each stimulated echo. While "contiguous" GRASTE exploits all stimulated echoes for the central part of k-space and the gradient echoes for outer lines, "interleaved" GRASTE assigns all echoes of a particular readout interval to directly neighboring lines. Phase distortions may be corrected by the reference signals of a single readout interval without phase encoding. Experimental results obtained for the human brain demonstrate that contiguous GRASTE yields up to 30% better SNR per acquisition time than conventional single-shot STEAM due to a better efficiency and maintains most of its robustness. Interleaved GRASTE can improve the SNR by a factor of 2 because of the possibility of using larger flip angles in the readout interval. However, its more pronounced sensitivity to off-resonance effects requires short echo trains.

Brain Mapping↗

Half-Fourier single-shot STEAM MRI.

As a high-speed imaging technique based on stimulated echoes single-shot STEAM MRI is insensitive to chemical shift artifacts and magnetic susceptibility differences. The achievable signal-to-noise ratio (SNR) is limited by the fact that high flip angles of the read-out excitation pulses cause a steep decay of the stimulated echo train and therefore degrade the point-spread function of the resulting image. The present work investigates the use of half-Fourier phase encoding which weakens the flip angle constraint by reducing the number of necessary excitations. Single-shot STEAM MRI of the normal human brain at 2.0 T demonstrates that half-Fourier versions either reduce the measurement time by almost a factor of two without sacrificing the SNR or increase the SNR by about 40% while keeping the measurement time constant.

Brain↗

Two-dimensional spatially-selective RF excitation pulses in echo-planar imaging.

Two-dimensional spatially-selective RF (2DRF) excitation pulses were developed for single-shot echo-planar imaging (EPI) with reduced field of view (FOV) in the phase-encoding direction. The decreased number of k-space lines significantly shortens the length of the EPI echo train. Thus, both gradient-echo and spin-echo 2DRF-EPI images of the human brain at 2.0 T exhibit markedly reduced susceptibility artifacts in regions close to major air cavities. Based on a blipped-planar trajectory, implementation of a typical 2DRF pulse resulted in a 26-ms pulse duration, a 5-mm section thickness, a 40-mm FOV along the phase-encoding direction, and a 200-mm distance of the unavoidable side excitations from the center of the FOV. For the above conditions and at 2 x 2 mm(2) resolution, 2DRF-EPI yielded an echo train length of only 21 ms, as opposed to 102 ms for conventional EPI. This gain in time may be used to achieve higher spatial resolution. For example, spin-echo 2DRF-EPI of a 40-mm FOV at 1 x 1 mm(2) resolution led to an echo train of 66 ms. Although the current implementation still lacks user-friendliness, 2DRF pulses are likely to become a useful addition to the arsenal of advanced MRI tools. .

Brain↗