PubMed Health⌕ Search

Biomedical subjects

Jürgen R Reichenbach

Publications and source records attributed to Jürgen R Reichenbach.

36 records · Page 2Linked to original sources

Application of an exogenous hyperoxic contrast agent in MR mammography: initial results.

There is interest in applying novel methods to dynamic MR mammography (MRM). One such possibility is to administer an exogenous hyperoxic contrast agent, such as carbogen (95-98% O2 and 2-5% CO2) or pure oxygen (100% O2). We report our first experiences with these agents in a patient with an invasive lobular carcinoma. Fourteen dynamic series were acquired with an rf-spoiled 2D multislice gradient echo sequence, including three measurements while breathing air, four measurements with 100% oxygen, three measurements with air and four measurements with carbogen. Afterwards, 0.1 mmol/kg bw of Gd-DTPA was administered to obtain dynamic T1-weighted double-echo 3D axial gradient echo images (TR/TE1/TE2/alpha=7.8 ms/2 ms/4.76 ms/15 degrees) every 90 s up to 4.5 min after injection. The lesion was well delineated on the contrast-enhanced images, contrary to magnitude images reconstructed from the raw data sets acquired during air/oxygen/carbogen breathing. A ROI-based median-filtered signal-time course revealed a tumor signal increase of roughly 15% between scans acquired during air and oxygen breathing. Though preliminary, these first results are encouraging concerning the exploration of these alternative contrast agents in MRM in greater detail.

Breast Neoplasms↗

Pediatric brain MRI in neurofibromatosis type I.

Neurofibromatosis (NF) is the most common of the phakomatoses, with a prevalence of 1 in 3-4,000. Many organ systems can be affected. In addition to multiple peripheral neurofibromas, NF I predisposed to CNS tumors including optic glioma, astrocytoma and plexiform neurofibroma. The purpose of this pictorial review is to illustrate characteristic brain MR imaging lesions in children with NF I and to give some recommendations about diagnostic imaging procedures in children suffering from NF I. Typical findings in brain MRI are hyperintense lesion on T2-weighted images, so-called unknown bright objects, which may be useful as an additional imaging criterion for NF I. Contrast administration is necessary in MR studies to maximize tumor detection and characterization, to add confidence to the diagnosis of benign probable myelin vacuolization, and to document stability of neoplasm on follow-up examinations. We recommend to perform serial MR imaging in children every 12 months. The frequency of follow-up in children with known brain tumors will vary with the tumor grade, biological activity and treatment.

Adolescent↗

Effect of routine MR imaging of the brain at 1.5 T on subsequent magnetoencephalography: results in nine volunteers.

PURPOSE: To investigate whether routine magnetic resonance (MR) imaging of the brain with a whole-body 1.5-T imager affects the results of subsequent magnetoencephalography (MEG). MATERIALS AND METHODS: Nine healthy volunteers (six women, mean age of 23 years, age range of 20-27 years; three men, mean age of 24 years, age range of 23-25 years) underwent one MEG session before and two MEG sessions after MR imaging of the brain. The first MEG session was completed about 20 minutes before brain MR imaging began, the second MEG session (MEG 2) was performed within 30 minutes after MR imaging, and the third MEG session was performed 2 hours after MEG 2. Each MEG session involved measurement of spontaneous brain activity and, in seven patients, of brain activity during stimulation of the median nerve. MR imaging included T1- and T2-weighted fast spin-echo and gradient-echo sequences applied with a 1.5-T clinical imager. Data were compared by using a repeated-measures analysis of variance (general linear model) both with and without Greenhouse-Geisser correction. RESULTS: MEG signals were detected and measured without difficulty in all volunteers. No statistically significant difference was seen between estimated noise at MEG before and after MR imaging (P =.588 with correction, P =.665 without correction). MEG records obtained in all volunteers enabled localization of evoked response to median nerve stimulation before and after MR imaging. No measurable differences were observed between relative power spectra of spontaneous brain activity before and after MR imaging (P >.290 with correction, P >or=.295 without correction). CONCLUSION: No measurable effect of 1.5-T brain MR imaging on subsequent MEG was detected.

Adult↗

Susceptibility weighted imaging (SWI).

Susceptibility differences between tissues can be utilized as a new type of contrast in MRI that is different from spin density, T1-, or T2-weighted imaging. Signals from substances with different magnetic susceptibilities compared to their neighboring tissue will become out of phase with these tissues at sufficiently long echo times (TEs). Thus, phase imaging offers a means of enhancing contrast in MRI. Specifically, the phase images themselves can provide excellent contrast between gray matter (GM) and white matter (WM), iron-laden tissues, venous blood vessels, and other tissues with susceptibilities that are different from the background tissue. Also, for the first time, projection phase images are shown to demonstrate tissue (vessel) continuity. In this work, the best approach for combining magnitude and phase images is discussed. The phase images are high-pass-filtered and then transformed to a special phase mask that varies in amplitude between zero and unity. This mask is multiplied a few times into the original magnitude image to create enhanced contrast between tissues with different susceptibilities. For this reason, this method is referred to as susceptibility-weighted imaging (SWI). Mathematical arguments are presented to determine the number of phase mask multiplications that should take place. Examples are given for enhancing GM/WM contrast and water/fat contrast, identifying brain iron, and visualizing veins in the brain.

Body Water↗

Event-related fMRI with painful electrical stimulation of the trigeminal nerve.

Several functional brain imaging studies of pain using positron emission tomography (PET) and functional magnetic resonance imaging (fMRI) have shown that painful stimulation causes activation of different brain areas. The aim of the present study was to develop and implement painful stimulation of the trigeminal nerve, which can be applied with event-related paradigms by using MRI. Twelve healthy, right-handed volunteers were examined. Painful electrical stimulation of the first trigeminal branch was performed. In an event-related setting with a 1.5 T clinical scanner with EPI capability, the following fMRI parameters were used: 20 slices, 3 mm thickness, isotropic voxel, 306 measurements with 54 randomized events. Statistical postprocessing was performed with SPM99. Activation of the ipsi- and contralateral secondary somatosensory cortex (SII), and the contralateral insular cortex was observed as well as a contralateral thalamic activation (T=4.45, extension 15 voxels). Six of the 12 volunteers revealed also activation of the cingulate cortex. The investigation demonstrates that painful stimulation of the trigeminal nerve activates the contralateral insular cortex, SII, and thalamus, as well as the ipsilateral SII. In contrast to other studies, the cingulate cortex was only activated inconsistently.

Adult↗

Brain activation to phobia-related pictures in spider phobic humans: an event-related functional magnetic resonance imaging study.

Using event-related functional magnetic resonance imaging we investigated blood oxygen level dependent brain activation in spider phobic and non-phobic subjects while exposed to phobia-related pictures (spiders) and non-phobia-related pictures (snakes and mushrooms). In contrast to previous studies, we show significantly increased amygdala activation in spider phobics, but not in controls, during presentation of phobia-relevant visual stimuli. Furthermore, phobia-specific increased activation was also found in the insula, the orbitofrontal cortex and the uncus. Our study confirms the role of the amygdala in fear processing and provides insights into brain activation patterns when animal phobics are confronted with phobia-related stimuli.

Adult↗

A manipulator system for 14-gauge large core breast biopsies inside a high-field whole-body MR scanner.

PURPOSE: To investigate a robotic manipulator system for MR-guided breast biopsies inside a 1.5 T whole-body magnet. MATERIALS AND METHODS: Fourteen patients with suspicious breast lesions (diameter 18.6 +/- 12 mm) underwent biopsy. Patients with malignant findings underwent surgery afterwards and the histologic findings between biopsy and surgery were correlated. RESULTS: In five patients biopsy findings were histopathologically confirmed following open surgery. One tubular carcinoma was missed; one invasive cancer was underestimated. Seven patients with benign findings are still in the follow-up period. CONCLUSION: The study demonstrates the feasibility to perform breast biopsies inside the magnet of a whole-body MR scanner by using a manipulator system.

Biopsy↗

Automated unwrapping of MR phase images applied to BOLD MR-venography at 3 Tesla.

PURPOSE: To improve the diagnostic value of BOLD MR-Venography by removing artifacts related to phase wrapping, particularly in regions of large background susceptibilities at high magnetic field strengths. MATERIALS AND METHODS: High resolution, T(2)(*)-weighted, single echo images were acquired on a 3 T system (Medspec 30/80 Avance, Bruker Medical, Ettlingen, Germany) with a three-dimensional, first order velocity compensated gradient echo sequence using a quadrature transmit/receive birdcage head coil. Data of nine healthy subjects and 19 patients were evaluated (age range: 27 to 76 years). To achieve improved MR-venograms, a fully automated region-growing phase unwrapping algorithm and subsequent high pass filtering were applied to phase images prior to the computation of minimum intensity projections. RESULTS: Considerably improved visualization of venous structures in regions of large background susceptibility-induced field inhomogeneities is demonstrated in healthy subjects and patients with brain tumors. CONCLUSION: BOLD MR venograms are improved compared to previous post-processing algorithms. It is now feasible to obtain high-resolution images also in inhomogeneous regions, which increases the clinical potential of BOLD MR-Venography.

Adult↗

[Interventional MR-mammography: manipulator-assisted large core biopsy and interstitial laser therapy of tumors of the female breast]].

The present study investigated the clinical application of magnetic resonance (MR)-guided breast interventions, such as manipulator-assisted large core breast biopsy (LCBB) inside a 1.5 T whole-body magnet and MR-guided interstitial laser therapy (ILT). Sixteen patients underwent LCBB and 1 additional patient underwent 4 sessions of ILT of a recurrent undifferentiated lymph node metastasis in the axilla using a Nd-YAG laser (1064 nm). Temperature changes of the tumor tissue during ILT were monitored using phase images of a gradient echo sequence (GRE) (TR/TE/FA = 25/12/30). In 5 patients the biopsy findings were histopathologically confirmed after open surgery. In 3 patients, the biopsy missed one tubular and one ductal carcinoma; one invasive carcinoma was underestimated. Eight patients with benign findings are still in the follow-up period. The heating zone during ILT was well delineated on subtracted phase images. No severe adverse events were observed with LCBB or ILT. MR-guided breast biopsies are feasible with the manipulator system inside a whole-body 1.5 Tesla MR scanner. GRE information is suitable for therapy monitoring during ILT within the tumor. Further studies are necessary to evaluate the accuracy of the manipulator system and the efficacy of ILT in the treatment of breast lesions.

Aged↗

Dedicated double breast coil for magnetic resonance mammography imaging, biopsy, and preoperative localization.

RATIONALE AND OBJECTIVES: The aim of this study was to compare the performance of a dedicated double breast coil for MR imaging and intervention with a standard diagnostic double breast coil. MATERIALS AND METHODS: Signal-to-noise ratios (SNRs) were determined for both coils by using a water phantom. Fourteen patients were examined, 11 underwent preoperative hookwire localization, two were biopsied, and one received diagnostic imaging. Breast images were acquired in three patients with both coils and were visually compared. Harvested specimen from the biopsies and surgeries following hookwire localization were histopathologically evaluated. RESULTS: SNR was superior with the interventional coil in the posterior (axillary) part of the imaging volume and inferior in the anterior part compared with the standard coil. Anatomic MR breast images were of similar diagnostic quality. For the two biopsy procedures the trocar was correctly placed in front of the suspicious lesion. Hookwires were correctly located inside the lesion in nine patients and in contact with the lesion in one patient. In one patient a 2 mm distance between the lesion and the wire was observed. CONCLUSIONS: Diagnostic imaging followed by subsequent MR-guided intervention is possible within a single session by using the dedicated interventional coil. The correct final position of the hookwires demonstrates the precision of the MR guided localization procedure.

Adult↗

High-resolution three-dimensional contrast-enhanced blood oxygenation level-dependent magnetic resonance venography of brain tumors at 3 Tesla: first clinical experience and comparison with 1.5 Tesla.

RATIONALE AND OBJECTIVES: To evaluate the clinical potential of high-resolution 3D contrast-enhanced blood oxygenation level-dependent MR-Venography (CE-MRV) for primary brain tumors and metastases at 3 Tesla (T) in comparison to 1.5 T. METHODS: Eighteen patients with brain tumors were examined using CE-MRV after application of a standard dose of MRI contrast agent (0.1 mmol/kg gadodiamide). CE-MRV is based on a high-resolution 3D flow-compensated gradient-echo sequence with long echo times that uses the contrast-enhanced blood oxygenation level-dependent effect. This technique was performed using the same volume coverage and acquisition time at both field strengths after performing standard imaging sequences. RESULTS: The higher spatial resolution of CE-MRV at 3 T showed more details within and around tumors than at 1.5 T. Visibility was enhanced by stronger susceptibility weighting and higher intrinsic signal-to-noise at 3 T. Compared with standard imaging protocols, additional information characterized as tubular and nontubular hypointense structures were found within or around lesions on CE-MRV images. CONCLUSIONS: Acquisition of CE-MRV data at 3 T enables spatial resolution to be increased within the same measurement time and with the same volume coverage compared with 1.5 T, thus providing more detailed information. The method may also show the potential to estimate oxygen supply of tumors, especially at high field strengths.

Adult↗

MR Imaging in Wegener granulomatosis of the spinal cord.

Wegener granulomatosis is a multisystemic disorder characterized by necrotizing vasculitis that primarily involves the respiratory tract. The orbits, heart, skin, joints, and nervous system are frequently involved. We describe the MR imaging findings of Wegener granulomatosis in the cervical spine and correlate them with the histopathologic features. MR imaging showed epidural liquid masses surrounded by granulomatous masses that compressed the cervical myelin from behind.

Cervical Vertebrae↗

MRI of the pelvic ring joints postpartum: normal and pathological findings.

PURPOSE: To assess the joints of the pelvic ring postpartum and to discern normal postpartum findings and pathologic lesions using MRI. MATERIALS AND METHODS: MR images were obtained in six women with severe pelvic ring pain after delivery, in 13 women after uncomplicated vaginal delivery, and in 11 healthy, nulliparous non-pregnant volunteers. Distances of the pubic gap, signal intensities of the pubic cartilage, and signal changes of the pelvic ring bones were determined and evaluated. RESULTS: Both postpartum groups had significantly larger distances of the interpubic gap compared to the nulliparous group (P = 0.0002). The mean signal intensity of cartilage of the symphysis pubis was significantly different on the T1-weighted and T2-weighted MR images in postpartum women compared to nulliparous women (P = 0.001), indicating a higher water content of the pubic cartilage. 13 of all 19 postpartum women had bruises of parasymphyseal pubic bones. One pubic symphysis rupture and one sacral stress fracture were detected in two symptomatic women. CONCLUSION: MR imaging is a useful adjunct to clinical examination to identify patients with lesions of the pelvic ring postpartum. MRI of the pelvic ring of asymptomatic postpartum women can demonstrate signal changes of the pubic cartilage and small bruises of the pubic bones.

Adult↗

Negative dip in BOLD fMRI is caused by blood flow--oxygen consumption uncoupling in humans.

The sensitivity of MRI for local changes in the deoxyhemoglobin concentration is the basis of the blood oxygen level dependent (BOLD) effect. Time-resolved fMRI studies during visual activation show an early signal intensity (SI) decrease indicating a short lasting uncoupling of oxygen consumption and cerebral blood flow (CBF) before a SI increase due to the overcompensating hemodynamic response occurs. Normal neuronal activity may be preserved despite absent vascular responsiveness. Here we show that a negative BOLD effect occurs during motor activation in an asymptomatic patient with severely disturbed cerebral autoregulation due to extracranial artery disease. This is thought to be due to oxygen consumption in the absence of a hemodynamic response. This rare case of a persisting uncoupling of oxygen metabolism and CBF serves as a model that supports changes of the cerebral blood oxygen saturation as the major contributor of the BOLD effect.

Aged↗

Development and validation of an algorithm for registration of serial 3D MR breast data sets.

We report on the development of an algorithm to improve the registration of serial 3D MR breast images using combined global translation and rotation with locally varying parameters as geometric transformations. Several phantom and volunteer data sets were acquired and registered using mutual information as a similarity measure of the matching process. After applying a global translation by using a rigid matcher, optimum horizontal and vertical rotation angles were determined. In case of the phantom measurements, angle optimization was performed for each slice of the 3D data set of the phantom, which was deliberately shifted and rotated around different axes. In case of registration of volunteer data, optimum rotation parameters were calculated for pre-selected equidistant slices of the data set to speed up the calculation time. For slices located between and outside these support slices, the rotation angles were calculated by linear interpolation and extrapolation of the slope of the regression determined by the optimized angles of the support slices. The algorithm improves the registration of serial 3D MR data sets and represents a compromise between a rigid and an elastic 3D matching procedure.

Adult↗

Radio-frequency tumor ablation: internally cooled electrode versus saline-enhanced technique in an aggressive rabbit tumor model.

PURPOSE: To compare two methods of radio-frequency (RF) ablation, saline enhancement technique and internally cooled electrodes, for the treatment of small breast cancers in an animal model--highly aggressive VX2 rabbit tumors surrounded by adipose tissue. MATERIALS AND METHODS: Twenty-seven tumors were implanted into retroperitoneal fat of 14 New Zealand White rabbits. RF ablation was performed with ultrasonographic (US) guidance after tumors had grown to 15 mm. Fourteen tumors in seven animals were treated with internally cooled electrodes (30-mm-tip single electrode, 60 W, 10 min); 13 tumors in seven animals, with saline enhancement (0.5 mL/min of saline, 25-mm tip, 30 W, 10 min). Autopsy and histopathologic assessment were performed 3 weeks after therapy. RESULTS: Real-time US of RF ablation was not possible with either method because of obscuration by the increasing hyperechogenicity of the tumor and the surrounding adipose tissue. Equivalent efficacy was demonstrated with the two methods. Significantly greater complications were observed with the saline technique: Free retroperitoneal fluid was detected in one of seven animals with internally cooled electrodes and in all seven animals with saline enhancement (P <.01). Damage to remote structures such as the kidney, spine muscle, and skin was observed at autopsy in one of seven animals with internally cooled technique versus five of seven with saline enhancement (P <.01). CONCLUSION: Given a lower complication rate and similar treatment efficacy in an animal tumor model, internally cooled RF electrode may be advantageous to adjuvant saline infusion for the minimally invasive treatment of breast tumors.

Animals↗

Computerized modeling based on spiral CT data for noninvasive determination of aortic stent-graft length.

PURPOSE: To preprocedurally determine the correct length of a nonbifurcated endovascular prosthesis for abdominal aortic aneurysm (AAA) repair using a computerized model. METHODS: A computer program was implemented to calculate the optimal intraluminal course of nonbifurcated stent-grafts from spiral computed tomographic (CT) images of the aortic lumen reconstructed at 2.5, 5, and 10-mm slice thicknesses. The algorithm was tested using 10 phantoms fabricated from 150-mm-long, 10-mm-diameter copper rods that were bent into shapes mimicking different aortic configurations. Midpoint coordinates and rod diameters were determined from each CT image by 3 independent observers and served as input parameters to the program. The influence of the different CT reconstructions on the calculated lengths and possible observer dependence were assessed using calculated length estimation errors. Spiral CT images from 20 consecutive AAA patients scanned before stent-graft implantation were also processed to evaluate the algorithm under clinical conditions. RESULTS: Length estimation errors of the phantoms depended on the degree of bending as well as on the CT reconstruction slice thickness but were observer independent. Maximum errors were 7% for the 10-mm slices, 3.5% for the 5-mm slices, and 1.2% for a 2.5-mm reconstruction. The mean longitudinal shortening of the aorta due to vessel tortuosity was 9.1% +/- 4.8% among the 20 patients. Based on the results of the phantom study, errors of the calculated stent-graft lengths in patients were estimated to be approximately 1% for a 5-mm CT reconstruction increment and <2% for a 10-mm increment. CONCLUSIONS: The proposed algorithm makes it possible to calculate noninvasively the correct length of straight stent-grafts under clinical conditions with a 1% to 2% error.

Algorithms↗

Cortical blindness after contrast-enhanced CT: complication in a patient with diabetes insipidus.

Transient cortical blindness is an uncommon but well-known complication following cerebral angiography. One possible cause of this complication is an adverse reaction to contrast agent, resulting in an osmotic disruption of the blood-brain barrier that seems to be selective for the occipital cortex. We report the case of a 16-year-old male patient with cortical blindness after intravenous application of nonionic contrast agent during CT angiography performed because of seizure that was attributed to thrombosis of the basilar artery on the basis of clinical findings. To our knowledge, the development of cortical blindness after CT angiography has not been described in the literature. The patient's symptoms were triggered by hyponatriemia and diabetes insipidus.

Adolescent↗