PubMed Health⌕ Search

Biomedical subjects

Jürgen Weese

Publications and source records attributed to Jürgen Weese.

4 recordsLinked to original sources

Fast maximum intensity projections of large medical data sets by exploiting hierarchical memory architectures.

Maximum intensity projections (MIPs) are an important visualization technique for angiographic data sets. Efficient data inspection requires frame rates of at least five frames per second at preserved image quality. Despite the advances in computer technology, this task remains a challenge. On the one hand, the sizes of computed tomography and magnetic resonance images are increasing rapidly. On the other hand, rendering algorithms do not automatically benefit from the advances in processor technology, especially for large data sets. This is due to the faster evolving processing power and the slower evolving memory access speed, which is bridged by hierarchical cache memory architectures. In this paper, we investigate memory access optimization methods and use them for generating MIPs on general-purpose central processing units (CPUs) and graphics processing units (GPUs), respectively. These methods can work on any level of the memory hierarchy, and we show that properly combined methods can optimize memory access on multiple levels of the hierarchy at the same time. We present performance measurements to compare different algorithm variants and illustrate the influence of the respective techniques. On current hardware, the efficient handling of the memory hierarchy for CPUs improves the rendering performance by a factor of 3 to 4. On GPUs, we observed that the effect is even larger, especially for large data sets. The methods can easily be adjusted to different hardware specifics, although their impact can vary considerably. They can also be used for other rendering techniques than MIPs, and their use for more general image processing task could be investigated in the future.

Computer Storage Devices↗

Projection extension for region of interest imaging in cone-beam CT.

RATIONALE AND OBJECTIVES: For 3D X-ray imaging during interventions, changes of the imaged object are often restricted to a small part of the field of view, suggesting region of interest (ROI) imaging by irradiating this area only. In this article, we present a novel method for extension of truncated projections in order to avoid truncation artifacts in C-arm based 3D ROI imaging. MATERIALS AND METHODS: The method makes use of prior knowledge by combining forward projections of a previously acquired, nontruncated 3D reference image with the truncated ROI projections. Rigid registration between the two datasets is achieved by using a technique based on local cross-correlation. To account for a gray value mismatch between the two data sets due to, e.g., differing beam quality and different contributions of scattered radiation, a linear gray level transformation is applied to the forward-projected reference data. RESULTS: The performance of different gray value transformation schemes is systematically assessed by means of numerical simulations. For various simulated scenarios, the best performing transformation has been identified, providing practical guidelines for selecting a scheme depending on the origin of the gray-level mismatch. Experiments prove the high performance of the developed method. CONCLUSION: The presented technique enables almost artifact-free 3D ROI imaging during interventions. This actually allows for repeated scans at low dose and enables intraprocedural imaging of large objects even with a small detector. However, applicability of the method is limited to scenarios where direct access to a reference image, e.g., a prior CT scan, is available.

Computer Simulation↗

Automated segmentation of the left ventricle in cardiac MRI.

We present a fully automated deformable model technique for myocardium segmentation in 3D MRI. Loss of signal due to blood flow, partial volume effects and significant variation of surface grey value appearance make this a difficult problem. We integrate various sources of prior knowledge learned from annotated image data into a deformable model. Inter-individual shape variation is represented by a statistical point distribution model, and the spatial relationship of the epi- and endocardium is modeled by adapting two coupled triangular surface meshes. To robustly accommodate variation of grey value appearance around the myocardiac surface, a prior parametric spatially varying feature model is established by classification of grey value surface profiles. Quantitative validation of 121 3D MRI datasets in end-diastolic (end-systolic) phase demonstrates accuracy and robustness, with 2.45 mm (2.84 mm) mean deviation from manual segmentation.

Algorithms↗

Automated 3-D PDM construction from segmented images using deformable models.

In recent years, several methods have been proposed for constructing statistical shape models to aid image analysis tasks by providing a priori knowledge. Examples include principal component analysis of manually or semiautomatically placed corresponding landmarks on the learning shapes [point distribution models (PDMs)], which is time consuming and subjective. However, automatically establishing surface correspondences continues to be a difficult problem. This paper presents a novel method for the automated construction of three-dimensional PDM from segmented images. Corresponding surface landmarks are established by adapting a triangulated learning shape to segmented volumetric images of the remaining shapes. The adaptation is based on a novel deformable model technique. We illustrate our approach using computed tomography data of the vertebra and the femur. We demonstrate that our method accurately represents and predicts shapes.

Algorithms↗