PubMed Health⌕ Search

Biomedical subjects

Jaan Noolandi

Publications and source records attributed to Jaan Noolandi.

5 recordsLinked to original sources

Glucose permeability of human, bovine, and porcine corneas in vitro.

PURPOSE: To measure glucose flux across human, bovine, and porcine corneas and to determine the diffusion coefficient of each type of cornea. METHODS: Diffusion of glucose across human (n = 8), bovine (n = 7), and pig corneas (n = 8) was measured using a modified blind well chamber apparatus (Boyden chamber). Dialysis membranes (n = 7) and nonporous Mylar membranes (n = 7) were used as positive and negative controls, respectively. Glucose concentrations were measured at 30-min intervals with a commercially available glucose meter. RESULTS: The diffusion of glucose through corneas in vitro was calculated by a simple Fickian diffusion model. The diffusion coefficient of glucose is highest for the human cornea (D(HC) = 3.0 +/- 0.2 x 10(-6) cm(2)/s) followed by porcine corneas (D(PC) = 1.8 +/- 0.6 x 10(-6) cm(2)/s) and bovine corneas (D(BC) = 1.6 +/- 0.1 x 10(-6) cm(2)/s) (p < 0.05). The diffusion coefficients of all tested corneas were significantly higher (p < 0.05) than that of dialysis membrane (D(DM) = 3.4 +/- 0.2 x 10(-7) cm(2)/s). CONCLUSION: The glucose diffusion coefficients of human, bovine, and porcine corneas are on the order of 10(-6). Human corneas have higher permeability to glucose than either porcine or bovine corneas.

Animals↗

Undulatory delamination of thin polymer films on gold surfaces.

Using two-dimensional surface plasmon resonance measurements, we have observed the formation of traveling waves in the delamination of thin films of polydimethylsilane (PDMS) exposed to methanol. Films were spin-coated on a gold surface and the methanol was added to the top surface. The stress-induced instability caused by the swelling of the PDMS thin film when its edge is pinned to the gold surface leads to wrinkle formation and propagation at the interface. The periodic pattern is thought to be the result of an Asaro-Tiller-Grinfeld (ATG) instability.

Crystallization↗

Localized chemical release from an artificial synapse chip.

A device that releases chemical compounds in small volumes and at multiple, well defined locations would be a powerful tool for clinical therapeutics and biological research. Many biomedical devices such as neurotransmitter-based prostheses or drug delivery devices require precise release of chemical compounds. Additionally, the ability to control chemical gradients will have applications in basic research such as studies of cell microenvironments, stem cell niches, metaplasia, or chemotaxis. We present such a device with repeatable delivery of chemical compounds at multiple locations on a chip surface. Using electroosmosis to drive flow through microfluidic channels, we pulse minute quantities of a bradykinin solution through four 5-microm apertures onto PC12 cells and show stimulation of individual cells using a Ca(2+)-sensitive fluorescent dye. We also present basic computational results with experimental verification of both fluid ejection and fluid withdrawal by imaging pH changes by using a fluorescent dye. This "artificial synapse chip" is a prototype neural interface that introduces a new paradigm for neural stimulation, with eventual application in treating macular degeneration and other neurological disorders.

Animals↗

Fluid flow past an aperture in a microfluidic channel.

Electroosmotically driven flow in neurotransmitter-based retinal prostheses offers a novel approach to interfacing the nervous system. Here, we show that electroosmotically driven flow in a microfluidic channel can be used either to eject or to withdraw fluid through a small aperture in the channel wall. We study this fluid movement numerically using a finite-element method and experimentally using microfabricated channels and apertures. Two devices are used to test the concept of fluid ejection and withdrawal: (1) a single, large channel with four apertures and (2) a prototype neural interface with four individually addressable apertures. We compared experimental and numerical results in microchannels using the observed pH dependence of the fluorescent dye fluorescein, finding good agreement between the results. Because of the simplicity and rapid response of electroosmotic flow, this technique may be useful for neurotransmitter-based neural interfaces.

Journal Article↗

The Artificial Synapse Chip: a flexible retinal interface based on directed retinal cell growth and neurotransmitter stimulation.

The Artificial Synapse Chip is an evolving design for a flexible retinal interface that aims to improve visual resolution of an electronic retinal prosthesis by addressing cells individually and mimicking the physiological stimulation achieved in synaptic transmission. We describe three novel approaches employed in the development of the Artificial Synapse Chip: (i) micropatterned substrates to direct retinal cell neurite growth to individual stimulation sites; (ii) a prototype retinal interface based on localized neurotransmitter delivery; and (iii) the use of soft materials to fabricate these devices. By patterning the growth of cells to individual stimulation sites, we can improve the selectivity of stimulation and decrease the associated power requirements. Moreover, we have microfabricated a neurotransmitter delivery system based on a 5- micro m aperture in a 500-nm-thick silicon nitride membrane overlying a microfluidic channel. This device can release neurotransmitter volumes as small as 2 pL, demonstrating the possibility of chemical-based prostheses. Finally, we have fabricated and implanted an equivalent device using soft flexible materials that conform to the retinal tissue more effectively. As many of the current retinal prosthesis devices use hard materials and electrical excitation at a lower resolution, our approach may provide more physiologic retinal stimulation.

Animals↗