PubMed Health⌕ Search

Biomedical subjects

Jacek A Koziel

Publications and source records attributed to Jacek A Koziel.

14 recordsLinked to original sources

Evaluation of zeolite for control of odorants emissions from simulated poultry manure storage.

Poultry operations are associated with emissions of aerial ammonia (NH3), volatile organic compounds (VOCs), and odor, and the magnitude of emissions is influenced by manure management practices. As a manure treatment additive, zeolites have been shown to have the potential to control NH3. Because of their properties it is also expected that zeolites could effectively adsorb VOCs and odor. The effectiveness of zeolite in controlling odor and VOCs was qualitatively evaluated in this controlled laboratory study involving simulated poultry manure storage. In the first two trials, zeolite was topically applied on nearly fresh laying hen manure at the rates of 0, 2.5, 5, and 10% (by weight). In the third trial, zeolite was topically applied at 5% with each addition of fresh manure into the storage vessel. Headspace samples from the emission vessels were collected with solid phase microextraction (SPME) and analyzed on a multidimensional-gas chromatograph-mass spectrometry-olfactometry (MDGC-MS-O) system for identification and prioritization of poultry manure odorants. Acetic acid, butanoic acid, isovaleric acid, indole, and skatole were consistently controlled in the headspace, with the reduction rate being proportional to the zeolite application rate. Dimethyl trisulfide and phenol were consistently generated, and with a few exceptions, the rate of generation was proportional to the application rate. Average reduction of the odor caused by all odorants evaluated with SPME-GC-O was 67% (+/-12%) and 51% (+/-26%) for the two topical applications, respectively, while no significant reduction of VOCs and odor was detected for the layered application.

Animals↗

Characterization of volatile organic compounds and odors by in-vivo sampling of beef cattle rumen gas, by solid-phase microextraction, and gas chromatography-mass spectrometry-olfactometry.

Volatile organic compounds (VOCs) and odors in cattle rumen gas have been characterized by in-vivo headspace sampling by solid-phase microextraction (SPME) and analysis by gas chromatography-mass spectrometry-olfactometry (GC-MS-O). A novel device enabling headspace SPME (HS-SPME) sampling through a cannula was designed, refined, and used to collect rumen gas samples from steers. A Carboxen-polydimethylsiloxane (PDMS) fiber (85 microm) was used for SPME sampling. Fifty VOCs from ten chemical groups were identified in the rumen headspace. The VOCs identified had a wide range of molecular weight (MW) (34 to 184), boiling point (-63.3 to 292 degrees C), vapor pressure (1.05x10(-5) to 1.17x10(2) Pa), and water solubility (0.66 to 1x10(6) mg L-1). Twenty-two of the compounds have a published odor detection thresholds (ODT) of less than 1 ppm. More than half of the compounds identified are reactive and have an estimated atmospheric lifetime of <24 h. The amounts of VFAs, sulfide compounds, phenolic compounds, and skatole, and the odor intensity of VFAs and sulfide compounds in the rumen gas were all higher after feeding than before feeding. These results indicate that rumen gases can be an important potential source of aerial emissions of reactive VOCs and odor. In-vivo sampling by SPME then GC-MS-O analysis can be a useful tool for qualitative characterization of rumen gases, digestion, and its relationship to odor and VOC formation.

Animal Feed↗

Emissions of ammonia, hydrogen sulfide, and odor before, during, and after slurry removal from a deep-pit swine finisher.

It is a common practice in the midwestern United States to raise swine in buildings with under-floor slurry storage systems designed to store manure for up to one year. These so-called "deep-pit" systems are a concentrated source for the emissions of ammonia (NH3), hydrogen sulfide (H2S), and odors. As part of a larger six-state research effort (U.S. Department of Agriculture-Initiative for Future Agriculture and Food Systems Project, "Aerial Pollutant Emissions from Confined Animal Buildings"), realtime NH3 and H2S with incremental odor emission data were collected for two annual slurry removal events. For this study, two 1000-head deep-pit swine finishing facilities in central Iowa were monitored with one-year storage of slurry maintained in a 2.4 m-deep concrete pit (or holding tank) below the animal-occupied zone. Results show that the H2S emission, measured during four independent slurry removal events over two years, increased by an average of 61.9 times relative to the before-removal H2S emission levels. This increase persisted during the agitation process of the slurry that on average occurred over an 8-hr time period. At the conclusion of slurry agitation, the H2S emission decreased by an average of 10.4 times the before-removal emission level. NH3 emission during agitation increased by an average of 4.6 times the before-removal emission level and increased by an average of 1.5 times the before-removal emission level after slurry removal was completed. Odor emission increased by a factor of 3.4 times the before-removal odor emission level and decreased after the slurry-removal event by a factor of 5.6 times the before-removal emission level. The results indicate that maintaining an adequate barn ventilation rate regardless of animal comfort demand is essential to keeping gas levels inside the barn below hazardous levels.

Air Pollution, Indoor↗

Characterization of livestock odors using steel plates, solid-phase microextraction, and multidimensional gas chromatography-mass spectrometry-olfactometry.

Livestock operations are associated with emissions of odor, gases, and particulate matter (PM). Livestock odor characterization is one of the most challenging analytical tasks. This is because odor-causing gases are often present at very low concentrations in a complex matrix of less important or irrelevant gases. The objective of this project was to develop a set of characteristic reference odors from a swine barn in Iowa and, in the process, identify compounds causing characteristic swine odor. Odor samples were collected using a novel sampling methodology consisting of clean steel plates exposed inside and around the swine barn for < or =1 week. Steel plates were then transported to the laboratory and stored in clean jars. Headspace solid-phase microextraction was used to extract characteristic odorants collected on the plates. All of the analyses were conducted on a gas chromatography-mass spectrometry-olfactometry system where the human nose is used as a detector simultaneously with chemical analysis via mass spectrometry. Multidimensional chromatography was used to isolate and identify chemicals with high-characteristic swine odor. The effects of sampling time, distance from a source, and the presence of PM on the abundance of specific gases, odor intensity, and odor character were tested. Steel plates were effectively able to collect key volatile compounds and odorants. The abundance of specific gases and odor was amplified when plates collected PM. The results of this research indicate that PM is major carrier of odor and several key swine odorants. Three odor panelists were consistent in identifying p-cresol as closely resembling characteristic swine odor, as well as attributing to p-cresol the largest odor response out of the samples. Further research is warranted to determine how the control of PM emissions from swine housing could affect odor emissions.

Animals↗

Quality-assured measurements of animal building emissions: particulate matter concentrations.

Federally funded, multistate field studies were initiated in 2002 to measure emissions of particulate matter (PM) < 10 microm (PM10) and total suspended particulate (TSP), ammonia, hydrogen sulfide, carbon dioxide, methane, nonmethane hydrocarbons, and odor from swine and poultry production buildings in the United States. This paper describes the use of a continuous PM analyzer based on the tapered element oscillating microbalance (TEOM). In these studies, the TEOM was used to measure PM emissions at identical locations in paired barns. Measuring PM concentrations in swine and poultry barns, compared with measuring PM in ambient air, required more frequent maintenance of the TEOM. External screens were used to prevent rapid plugging of the insect screen in the PM10 preseparator inlet. Minute means of mass concentrations exhibited a sinusoidal pattern that followed the variation of relative humidity, indicating that mass concentration measurements were affected by water vapor condensation onto and evaporation of moisture from the TEOM filter. Filter loading increased the humidity effect, most likely because of increased water vapor adsorption capacity of added PM. In a single layer barn study, collocated TEOMs, equipped with TSP and PM10 inlets, corresponded well when placed near the inlets of exhaust fans in a layer barn. Initial data showed that average daily mean concentrations of TSP, PM10, and PM2.5 concentrations at a layer barn were 1440 +/- 182 microg/m3 (n = 2), 553 +/- 79 microg/m3 (n = 4), and 33 +/- 75 microg/m3 (n = 1), respectively. The daily mean TSP concentration (n = 1) of a swine barn sprinkled with soybean oil was 67% lower than an untreated swine barn, which had a daily mean TSP concentration of 1143 +/- 619 microg/m3. The daily mean ambient TSP concentration (n = 1) near the swine barns was 25 +/- 8 microg/m3. Concentrations of PM inside the swine barns were correlated to pig activity.

Air Pollutants↗

Quality assured measurements of animal building emissions: gas concentrations.

Comprehensive field studies were initiated in 2002 to measure emissions of ammonia (NH3), hydrogen sulfide (H2S), carbon dioxide (CO2), methane (CH4), nonmethane hydrocarbons (NMHC), particulate matter <10 microm in diameter, and total suspended particulate from swine and poultry production buildings in the United States. This paper focuses on the quasicontinuous gas concentration measurement at multiple locations among paired barns in seven states. Documented principles, used in air pollution monitoring at industrial sources, were applied in developing quality assurance (QA) project plans for these studies. Air was sampled from multiple locations with each gas analyzed with one high quality commercial gas analyzer that was located in an environmentally controlled on-farm instrument shelter. A nominal 4 L/min gas sampling system was designed and constructed with Teflon wetted surfaces, bypass pumping, and sample line flow and pressure sensors. Three-way solenoids were used to automatically switch between multiple gas sampling lines with > or =10 min sampling intervals. Inside and outside gas sampling probes were between 10 and 115 m away from the analyzers. Analyzers used chemiluminescence, fluorescence, photoacoustic infrared, and photoionization detectors for NH3, H2S, CO2, CH4, and NMHC, respectively. Data were collected using personal computer-based data acquisition hardware and software. This paper discusses the methodology of gas concentration measurements and the unique challenges that livestock barns pose for achieving desired accuracy and precision, data representativeness, comparability and completeness, and instrument calibration and maintenance.

Air Pollutants↗

Solid-phase microextraction as a novel air sampling technology for improved, GC-olfactometry-based assessment of livestock odors.

Air sampling and characterization of odorous livestock gases is one of the most challenging analytical tasks. This is because of low concentrations, physicochemical properties, and problems with sample recoveries for typical odorants. Livestock operations emit a very complex mixture of volatile organic compounds (VOCs) and other gases. Many of these gases are odorous. Relatively little is known about the link between characteristic VOCs/gases and, specifically, about the impact of characteristic odorants downwind from sources. In this research, solid-phase microextraction (SPME) is used for field air sampling of odors downwind from swine and beef cattle operations. Sampling time ranges from 20 min to 1 h. Samples are analyzed using a commercial gas chromatography-mass spectrometry-olfactometry system. Odor profiling efforts are directed at odorant prioritization, with respect to distance from the source. The results indicate the odor downwind is increasingly defined by a smaller number of high-priority odorants. These "character defining" odorants appear to be dominated by compounds of relatively low volatility, high molecular weight, and high polarity. In particular, p-cresol alone appears to carry much of the overall odor impact for swine and beef cattle operations. Of particular interest is the character-defining odor impact of p-cresol as far as 16 km downwind of the nearest beef cattle feedlot. The findings are highly relevant to scientists and engineers working on improved air sampling and analysis protocols and on improved technologies for odor abatement. More research evaluating the use of p-cresol and a few other key odorants as a surrogate for overall odor dispersion modeling is warranted.

Animals↗

Characterization of volatile organic compounds and odorants associated with swine barn particulate matter using solid-phase microextraction and gas chromatography-mass spectrometry-olfactometry.

Swine operations can affect air quality by emissions of odor, volatile organic compounds (VOCs) and other gases, and particulate matter (PM). Particulate matter has been proposed to be an important pathway for carrying odor. However, little is known about the odor-VOCs-PM interactions. In this research, continuous PM sampling was conducted simultaneously with three collocated TEOM 1400a analyzers inside a 1000-head swine finish barn located in central Iowa. Each TEOM was fitted with total suspended particulate (TSP), PM-10, PM-2.5 and PM-1 preseparators. Used filters were stored in 40 mL vials and transported to the laboratory. VOCs adsorbed/absorbed to dust were allowed to equilibrate with vial headspace. Solid-phase microextraction (SPME) Carboxen/polydimethylsiloxane (PDMS) 85 microm fibers were used to extract VOCs. Simultaneous chemical and olfactometry analyses of VOCs and odor associated with swine PM were completed using a gas chromatography-mass spectrometry-olfactometry (GC-MS-O) system. Fifty VOCs categorized into nine chemical function groups were identified and confirmed with standards. Five of them are classified as hazardous air pollutants. VOCs were characterized with a wide range of molecular weight, boiling points, vapor pressures, water solubilities, odor detection thresholds, and atmospheric reactivities. All characteristic swine VOCs and odorants were present in PM and their abundance was proportional to PM size. However, the majority of VOCs and characteristic swine odorants were preferentially bound to smaller-size PM. The findings indicate that a significant fraction of swine odor can be carried by PM. Research of the effects of PM control on swine odor mitigation is warranted.

Animals↗

Multidimensional gas chromatography-olfactometry for the identification and prioritization of malodors from confined animal feeding operations.

Odor profiling efforts were directed at applying to high-density livestock operations some of the lessons learned in resolving past, highly diverse, odor-focused investigations in the consumer product industry. Solid-phase microextraction (SPME) was used for field air sampling of odorous air near and downwind of a beef cattle feedyard and a swine finisher barn in Texas. Multidimensional gas chromatography-olfactometry (MDGC-O) was utilized in an attempt to define and prioritize the basic building blocks of odor character associated with these livestock operations. Although scores of potential odorant volatiles have been previously identified in high-density livestock operations, the odor profile results developed herein suggest that only a very few of these may constitute the preponderance of the odor complaints associated with these environments. This appeared to be especially true for the case of increasing distance from both cattle feedyard and swine barn facilities, with p-cresol consistently taking on the dominant odor impact role with ever increasing distance. In contrast, at- or near-site odor profiles were shown to be much more complex, with many of the well-known lower tier odorant compounds rising in relative significance. For the cattle feedyard at- or near-site odor profiles, trimethylamine was shown to represent a significantly greater individual odor impact relative to the more often cited livestock odorants such as hydrogen sulfide, the organic sulfides, and volatile fatty acids. This study demonstrates that SPME combined with a MDGC-O-mass spectrometry system can be used for the sampling, identification, and prioritization of odors associated with livestock.

Animal Feed↗

Evaluation of sample recovery of malodorous livestock gases from air sampling bags, solid-phase microextraction fibers, Tenax TA sorbent tubes, and sampling canisters.

Odorous gases associated with livestock operations are complex mixtures of hundreds if not thousands of compounds. Research is needed to know how best to sample and analyze these compounds. The main objective of this research was to compare recoveries of a standard gas mixture of 11 odorous compounds from the Carboxen/PDMS 75-microm solid-phase microextraction fibers, polyvinyl fluoride (PVF; Tedlar), fluorinated ethylene propylene copolymer (FEP; Teflon), foil, and polyethylene terephthalate (PET; Melinex) air sampling bags, sorbent 2,b-diphenylene-oxide polymer resin (Tenax TA) tubes, and standard 6-L Stabilizer sampling canisters after sample storage for 0.5, 24, and 120 (for sorbent tubes only) hrs at room temperature. The standard gas mixture consisted of 7 volatile fatty acids (VFAs) from acetic to hexanoic, and 4 semivolatile organic compounds including p-cresol, indole, 4-ethylphenol, and 2'-aminoacetophenone with concentrations ranging from 5.1 ppb for indole to 1270 ppb for acetic acid. On average, SPME had the highest mean recovery for all 11 gases of 106.2%, and 98.3% for 0.5- and 24-hr sample storage time, respectively. This was followed by the Tenax TA sorbent tubes (94.8% and 88.3%) for 24 and 120 hr, respectively; PET bags (71.7% and 47.2%), FEP bags (75.4% and 39.4%), commercial Tedlar bags (67.6% and 22.7%), in-house-made Tedlar bags (47.3% and 37.4%), foil bags (16.4% and 4.3%), and canisters (4.2% and 0.5%), for 0.5 and 24 hr, respectively. VFAs had higher recoveries than semivolatile organic compounds for all of the bags and canisters. New FEP bags and new foil bags had the lowest and the highest amounts of chemical impurities, respectively. New commercial Tedlar bags had measurable concentrations of N,N-dimethyl acetamide and phenol. Foil bags had measurable concentrations of acetic, propionic, butyric, valeric, and hexanoic acids.

Acetophenones↗

Sampling and analysis of volatile organic compounds in bovine breath by solid-phase microextraction and gas chromatography-mass spectrometry.

A relatively noninvasive method consisting of a face mask sampling device, solid-phase microextraction (SPME) fibers, and a gas chromatography-mass spectrometry (GC-MS) for the identification of volatile organic compounds (VOCs) in bovine breath was developed. Breath of three morbid steers with respiratory tract infections and three healthy steers were sampled seven times in 19 days for 15 min at each sampling. The breath VOCs adsorbed on the divinylbenzene (DVB)-Carboxen-polydimethyl siloxane (PDMS) 50/30 microm SPME fibers were transported to a laboratory GC-MS system for separation and identification with an in-house spectral library of standard chemicals. A total of 21 VOCs were detected, many of them for the first time in cattle breath. Statistical analyses using Chi-square test on the frequency of detection of each VOC in each group was performed. The presence of acetaldehyde (P < or = 0.05) and decanal (P < or = 0.10) were associated more with clinically morbid steers while methyl acetate, heptane, octanal, 2,3-butadione, hexanoic acid, and phenol were associated with healthy steers at P < or = 0.10. The results suggest that noninvasive heath screening using breath analyses could become a useful diagnostic tool for animals and humans.

Animals↗

Air sampling of aromatic hydrocarbons in the presence of ozone by solid-phase microextraction.

Effects of ozone on air sampling of standard gas mixtures of aromatic hydrocarbons were tested using solid-phase microextraction (SPME). Standard concentrations of ozone ranging from 10 ppb (v/v) to 6400 ppm (v/v) were generated using an in-house built ozone generator based on corona discharge. Effects of temperature, discharge voltage, and oxygen flow on the ozone generation were tested. The working dc voltage had the greatest effect on generated ozone concentration and was proportional to the ozone concentration. Generation temperature and oxygen flow rate were inversely proportional to ozone concentrations. Produced ozone was mixed with standard benzene, toluene, ethylbenzene, and xylenes (BTEX) gas at less than 100 ppb (v/v). Air samples were collected with poly(dimethylsiloxane) (PDMS) 100 microm SPME fibers and analyzed by gas chromatography (GC)-flame ionization detection (FID) and GC-MS. Significant reductions of BTEX concentrations were observed. In addition, some products of BTEX-ozone-oxygen reactions were identified. SPME worked well as a rapid sampler for BTEX and BTEX-ozone-oxygen reaction products. No significant deterioration of the PDMS coating and no significant reduction of absorption capacity were observed after repeated exposure to ozone.

Air↗

System for the generation of standard gas mixtures of volatile and semi-volatile organic compounds for calibrations of solid-phase microextraction and other sampling devices.

Standard gases are used for quality control and quality assurance, development of analysis methods and novel air sampling devices. The use of solid-phase microextraction (SPME) and other novel technologies for research in the area of air sampling and analysis requires systems/devices for reliable standard gas generation and sampling. In this paper we describe a new gas standard generating system for volatile organic compounds (VOCs) and semi-VOCs that was designed, built, and tested to facilitate fundamental and applications research with SPME. The system provided for the generation of a wide range of VOC/semi-VOC concentrations and mixing various standard gases, estimation of detection limits, testing the effects of sampling time, air temperature and relative humidity, testing the effects of air velocity and ozone on sampling/extractions. The system can be also used for calibrations of analytical instrumentation, quality control and quality assurance checks, and cross-validations of SPME with/and other sampling techniques.

Calibration↗

Calibration for on-site analysis of hydrocarbons in aqueous and gaseous samples using solid-phase microextraction.

Rapid sampling and sample preparation methodology was investigated using adsorptive poly(dimethylsiloxane)/divinylbenzene and Carboxen/poly(dimethylsiloxane) solid-phase microextraction (SPME) fiber coatings and volatile aromatic hydrocarbons (BTEX: benzene, toluene, ethylbenzene, and o-xylene). A flow-through system was used to generate a standard aqueous solution of BTEX as model sample with known linear velocity. Parameters that affect the extraction process, including sampling time, concentration, water velocity, and temperature, were investigated. Very short sampling times from 10 s and sorbents with strong affinity and large capacity were used to ensure the effect of '"zero sink" and to calibrate the extraction process in the initial linear extraction region. Several different concentrations were investigated, and it was found that mass uptake changes with concentration linearly. The increase of water velocity increases mass uptake, though the increase is not linear. Temperature does not affect mass uptake significantly under typical field sampling conditions. To further accurately describe rapid SPME analysis of aqueous samples, a new model translated from heat transfer to a circular cylinder in cross-flow was used. An empirical correlation to this model was used to predict the mass-transfer coefficient. Findings indicate that predicted mass uptake compares well with experimental mass uptake. The new model was tested for rapid air sampling, and it was found that this new model also predicted rapid air sampling accurately. Findings presented in this study extend the existing fundamental knowledge related to rapid sampling/sample preparation with SPME.

Journal Article↗