Fatigue resistance of endodontically treated teeth restored with three dowel-and-core systems.

STATEMENT OF PROBLEM: The successful restoration of endodontically treated teeth is enhanced by a crown design employing the ferrule effect. However, it is unclear which dowel-and-core system most effectively supports successful treatment. PURPOSE: The purpose of this study was to compare the load fatigue resistance of 3 dowel-and-core systems. MATERIAL AND METHODS: Fifteen endodontically treated maxillary central incisors were sectioned perpendicular to the long axis at a point 1.5 mm incisal to the cemento-enamel junction (CEJ). At the level of the CEJ, specimens were then prepared for crowns with 1-mm complete shoulder finish lines and 1.5 mm of axial wall height. The prepared teeth were divided into 3 groups (n=5) and restored with 1 of the following dowel-and-core combinations: Group CG, cast gold dowels and cores; Group TA, titanium alloy dowels (ParaPost XH) with composite cores; or Group FR, fiber-reinforced resin dowels (ParaPost FiberWhite) with composite cores. A dentin bonding agent (OptiBond Solo) was placed prior to the composite cores. Dowel-and-core castings and titanium alloy dowels were cemented with zinc phosphate cement. The fiber-reinforced dowels were cemented with a resin cement (ParaPost Cement). The crowns for all specimens were cast with an incisal notch for applying the fatigue load. The independent variable measured was the number of load fatigue cycles required to cause luting cement failure. The data were subjected to 1-way analysis of variance and the Student-Newman-Keuls test for 3 subsets (alpha=.05). RESULTS: The mean value+/-standard deviation for the cycles to failure for each group was: Group CG: 11,897+/-4080 load cycles, Group TA: 24,384+/-8231 load cycles, and Group FR: 50,696+/-7063 load cycles. Significant differences were found between all groups ( P<.05). CONCLUSIONS: Fiber-reinforced resin dowels and bonded composite cores under fatigue loading provided significantly stronger crown retention than cast gold dowels and cores and titanium alloy dowels with composite cores under fatigue loading.

Acrylic Resins↗

Comparison of two ultrasonic instruments for post removal.

The relative performance of two different ultrasonic units commonly used clinically for post removal was evaluated using tips designed specifically for post vibration. Twenty-four extracted maxillary and mandibular cuspids with crowns removed at the labial cementoenamel junction were treated endodontically. Post spaces were made 10 mm into the roots before cementing a 16 mm #5 (0.050-inch) Para-Post with zinc phosphate cement. The teeth were divided into three similar groups of eight. Post retention was assessed in group 1. Ultrasonic vibration was applied to groups 2 and 3 until post removal. The average force required to dislodge the posts from the teeth in group 1 (control group, no ultrasound) was 40.5 kg (SD = 12.3 kg). The average time for post removal in group 2 (Spartan) was 4:52 min (SD = 2:26). The average time for post removal in group 3 (Enac) was 1:31 min (SD = 0:34). The difference between groups 2 and 3 was statistically significant (p < 0.005). Use of ultrasonic tips designed for post vibration and maximization of audible sound level during ultrasonic treatment of posts seem to play an important role in the effectiveness and efficiency of post removal. The results obtained indicate that both the Enac ultrasonic unit with the ST-09 vibration tip and the Spartan ultrasonic unit with the Analytic VT-S tip were effective. Nevertheless, the Enac ultrasonic unit with the ST-09 vibration tip was clearly more efficient under these study conditions, resulting in typical post removal times of <2 min.

Cementation↗

Effect of core bonding on fatigue failure of compromised teeth.

PURPOSE: This study determined the effect of bonding a composite core on the number of load cycles to cement failure for teeth restored with complete crowns. MATERIALS AND METHODS: Ten extracted human maxillary central incisors were divided into two groups of five each. The tooth roots were at least 11 mm long, allowing an 8-mm post. Under copious irrigation, each tooth was cut to a flat plane 1 mm coronal to the buccal cementoenamel junction, perpendicular to the long axis of the tooth. The canal space was prepared to a final diameter of 1.25 mm, 8 mm deep. Each tooth was rebuilt with a 050 Parapost and Corestore. Final preparation height was 7 mm, including a 1-mm ferrule. For group 1, the core was bonded to the dentin using autocured Scotchbond Multipurpose Plus. For group 2, the core was not bonded. Following crown cementation, all teeth were subjected to a fatigue load of 4 kg at a rate of 280 cycles per minute. RESULTS: One tooth with a bonded core failed at 19,880 cycles, and the other four in this group did not fail after 100,000 cycles. All of the teeth without a bonded core failed at a cycle count of less than 100. The Mann-Whitney nonparametric test showed a significant difference between the two groups (P < .01). CONCLUSION: Bonding of a composite core to dentin prior to crown cementation provided a significantly stronger crown retention under fatigue loading.

Composite Resins↗

The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint.

PURPOSE: This study measured the gold screw preload at the gold cylinder-abutment screw joint interface obtained by 3 torque delivery systems. MATERIALS AND METHODS: Using a precalibrated, strain-gauged standard abutment as the load cell, 3 torque delivery systems tested were shown to have significant differences in gold screw preload when a gold cylinder was attached. RESULTS: Mean preloads measured were 291.2 N for hand torque drivers set at 10 Ncm, 340.3 N for electronic torque controllers at low setting/10 Ncm, 384.4 N for electronic torque controllers at high setting/10 Ncm; and 140.8 N for hand-tightening with a prosthetic slot screwdriver. Significant differences in screw preload were also found between operators using a hand torque driver. DISCUSSION: Hand-tightening delivered insufficient preload and cannot be recommended for final gold screw tightening. Different electronic torque controller units set at 10 Ncm induced mean gold screw preloads that ranged from 264.1 N to as high as 501.2 N. CONCLUSION: Electronic torque controllers should be regularly recalibrated to ensure optimal output.

Analysis of Variance↗

Fatigue load of teeth restored with bonded direct composite and indirect ceramic inlays in MOD class II cavity preparations.

PURPOSE: This study compared the fatigue life of human maxillary premolars restored with direct composites and indirect ceramic inlays in mesio-occlusodistal (MOD) cavities. MATERIALS AND METHODS: Ten human maxillary premolars were divided into two groups of five and restored with (1) direct composite restorations, or (2) pressed ceramic restorations. Standardized MOD cavities were prepared for both groups. Teeth in the direct composite group were restored with Z250 composite and Single Bond adhesive, and those in the ceramic group were restored with IPS Empress ceramic inlays. The ceramic inlays were luted with Single Bond and RelyX ARC cement. Under the applied test load of 11.17 kg, strain measurements were recorded from an electric resistance stain gauge bonded to the buccal surface. These strains were recorded for the (1) intact tooth, (2) cavity preparation, and (3) restored tooth. These strain measurements were used to calculate the relative tooth compliance values for each tooth. The fatigue loading was applied until reinforcement loss was registered by the strain gauge. RESULTS: A one-way ANOVA showed no significant compliance difference between the intact and restored tooth conditions, and no significant difference in fatigue cycles to failure between the two groups. CONCLUSION: There were both adhesive and cohesive failures in both restoration groups, indicating that the adhesive joint is not the only weak link in these restorations.

Aluminum Silicates↗

Critical bending moment of implant-abutment screw joint interfaces: effect of torque levels and implant diameter.

PURPOSE: Critical bending moment (CBM), the moment at which the external nonaxial load applied overcomes screw joint preload and causes loss of contact between the mating surfaces of the implant screw joint components, was measured with 2 types of implants and 2 types of abutments. MATERIALS AND METHODS: Using 4 test groups of 5 implant-abutment pairs, CBM at the implant-abutment screw joint was measured at 25%, 50%, 75%, and 100% of the manufacturer's recommended torque levels. Regular Platform (RP) Nobel Biocare implants (3.75 mm diameter), Wide Platform (WP) Nobel Biocare implants (5.0 mm diameter), CeraOne abutments, and Multiunit abutments were used. Microstrain was measured as loads were applied to the abutment at various distances from the implant-abutment interface. Strain instrumentation logged the strain data dynamically to determine the point of gap opening. All torque applications and strain measurements were repeated 5 times. RESULTS: For the CeraOne-RP group, the mean CBMs were 17.09 Ncm, 35.35 Ncm, 45.63 Ncm, and 62.64 Ncm at 25%, 50%, 75%, and 100% of the recommended torque level, respectively. For the CeraOne-WP group, mean CBMs were 28.29 Ncm, 62.97 Ncm, 92.20 Ncm, and 127.41 Ncm; for the Multiunit-RP group, 16.08 Ncm, 21.55 Ncm, 34.12 Ncm, and 39.46 Ncm; and for the Multiunit-WP group, 15.90 Ncm, 32.86 Ncm, 43.29 Ncm, and 61.55 Ncm at the 4 different torque levels. Two-way analysis of variance (ANOVA) (P < .001) revealed significant effects for the test groups (F = 2738.2) and torque levels (F = 2969.0). DISCUSSION: The methodology developed in this study allows confirmation of the gap opening of the screw joint for the test groups and determination of CBM at different torque levels. CONCLUSION: CBM was found to differ among abutment systems, implant diameters, and torque levels. The torque levels recommended by the manufacturer should followed to ensure screw joint integrity.

Analysis of Variance↗

Displacement of implant components from impressions to definitive casts.

PURPOSE: Four possible displacements of implant components from a patient model to a definitive cast were assessed to suggest a standard method of comparing the accuracies of implant impression techniques. MATERIALS AND METHODS: Two techniques for impression making were assessed: a nonsplinted open-tray technique and a light-curing resin splinted open-tray technique. A mandibular model with 5 parallel implants was fabricated. Five definitive casts were fabricated per technique. Using a computerized coordinate measuring machine, 5 part coordinate systems were established, and 7 sets of data were obtained for each sample. From the data, the amount of displacement while connecting components and the linear and angular displacement of components during impression making and cast fabrication were calculated. The Mann-Whitney test was used to determine significant differences between the impression techniques (P < .05). RESULTS: The average displacements while connecting impression copings and abutment replicas were 31.3 and 30.4 microm, respectively. Less displacement occurred in the nonsplinted group compared to the splinted group during impression making (P = .001) but greater displacement occurred in that group during definitive cast fabrication (P = .015). DISCUSSION: In contrast to previous studies, the current study excluded displacement resulting from component connection, because displacement from that source has no relation to impression technique and cannot be controlled. CONCLUSIONS: Connecting a component produced as great a displacement as that resulting solely from a impression or cast fabrication. The nonsplinted group was more accurate during impression making but less accurate during cast fabrication.

Acrylic Resins↗

Load fatigue performance of a single-tooth implant abutment system: effect of diameter.

PURPOSE: This study investigated the load fatigue performance of narrow-, regular-, and wide-diameter CeraOne (Nobel Biocare) single-tooth implants and abutments. MATERIALS AND METHODS: Five samples of each implant-abutment combination in 3 different widths were tested at 3 applied screw torque levels (recommended torque, recommended torque +20%, and recommended torque -20%). A rotational load fatigue machine was used to apply a 21-N load, at an angle of 45 degrees to the long axis of the specimens. This loading produced an effective bending moment of 35 Ncm at the abutment-implant interface. An upper cyclic limit was set at 5 x 10(6) load cycles for all specimens. RESULTS: Two-way analysis of variance revealed a significant difference between narrow-diameter and wide-diameter implant test groups but no significant difference between the 3 torque levels for each implant diameter. In the narrow-diameter group, 6 of the 15 specimens failed (5 abutment screw failures and 1 implant failure). In the regular-diameter group, 3 of the 15 specimens failed (2 implant failures and 1 abutment screw failure). There were no failures in the wide-diameter group. DISCUSSION: The results of this study indicate that the abutment screw is not the only potential failure location. The possibility of implant fracture clinically has been previously reported for prostheses supported by both single- and multiple-implant prostheses. CONCLUSION: The wide-diameter CeraOne single-tooth implant system demonstrated superior load fatigue performance. For clinical situations with significant functional loading, the narrow-diameter implants would be at a greater risk of fatigue failure.

Dental Abutments↗