Plug pattern optimization for gamma knife radiosurgery treatment planning.

PURPOSE: To develop a novel dose optimization algorithm for improving the sparing of critical structures during gamma knife radiosurgery by shaping the plug pattern of each individual shot. METHOD AND MATERIALS: We first use a geometric information (medial axis) aided guided evolutionary simulated annealing (GESA) optimization algorithm to determine the number of shots and isocenter location, size, and weight of each shot. Then we create a plug quality score system that checks the dose contribution to the volume of interest by each plug in the treatment plan. A positive score implies that the corresponding source could be open to improve tumor coverage, whereas a negative score means the source could be blocked for the purpose of sparing normal and critical structures. The plug pattern is then optimized via the GESA algorithm that is integrated with this score system. Weight and position of each shot are also tuned in this procedure. RESULTS: An acoustic tumor case is used to evaluate our algorithm. Compared to the treatment plan generated without plug patterns, adding an optimized plug pattern into the treatment planning process boosts tumor coverage index from 95.1% to 97.2%, reduces RTOG conformity index from 1.279 to 1.167, lowers Paddick's index from 1.34 to 1.20, and trims the critical structure receiving more than 30% maximum dose from 16 mm(3) to 6 mm(3). CONCLUSIONS: Automated GESA-based plug pattern optimization of gamma knife radiosurgery frees the treatment planning team from the manual forward planning procedure and provides an optimal treatment plan.

Algorithms↗

Implementation of the isocenter-shift technique for smoothing MLC field edge on a 3D treatment planning system.

Stepped leaf edges are the major limitation of conforming to the prescribed treatment contour defined by the conventional multileaf collimator (MLC), which produces a scalloped dose pattern. The commercial HD-270 MLC (HDI) technique provides a software solution of the conventional MLC to achieve smoothed edge and optimal penumbra of the MLC shaped field. We implemented the HDI functionality on a 3D treatment planning system and compared the dosimetric effects of the HDI delivery in simulation with those in experiment for a number of the MLC fields. The fields from the contour of varied shapes with different sizes of the leaf stepping were tested for the HDI delivery. There is a good agreement of the dose distribution between the calculation as implemented in the planning system and the measurement performed on the treatment machine. It has been shown that the HDI delivery significantly smooths the stepped field edge with the reduced isodose undulation and effective penumbra. A problem may be present when the HDI is applied for the treatment of the circular contour of smaller diameter, and the conformity of the MLC shaping may not be achievable satisfactorily with the existing system. The optimization of leaf configuration is suggested to improve the conformity of the HDI technique. The HDI planning then can be used to assist in the decision making of applying the HDI treatment delivery.

Humans↗