PubMed Health⌕ Search

Biomedical subjects

Jacob L Venzie

Publications and source records attributed to Jacob L Venzie.

3 recordsLinked to original sources

Electron-impact and glow-discharge ionization LC-MS analysis of green tea tincture.

A liquid chromatography-particle-beam mass spectrometer (LC-PB/MS) with interchangeable electron-impact (EI) and glow-discharge (GD) ion sources was evaluated for future application in analysis of botanical extracts. In this work a green tea tincture was characterized for a series of catechin components (catechin, epicatechin, epigallocatechin, and epigallocatechin gallate (EGCG)) and caffeine. Special emphasis was given to EGCG and caffeine, because they are important in determining the possible health effects of the green tea. The effects of instrument operating conditions were evaluated for the EI and GD ionization sources to determine their effect on analyte intensities and fragmentation patterns. These studies furnished information about the effects of these conditions in determining possible ionization pathways in the two ion sources. The mass spectra of these compounds obtained with the GD ion source are EI-like in appearance, with clearly identified molecular ions and fragmentation patterns that are easily rationalized. The absolute limits of detection for EGCG and caffeine were, respectively, 11 ng and 0.77 ng for the EI source and 3.2 ng and 0.61 ng for the GD source. The PB/EIMS and PB/GDMS combinations can be operated in a flow-injection mode, wherein the analyte is injected directly into the mobile phase, or coupled to high-performance liquid chromatography (HPLC), enabling LC-MS analysis of complex mixtures. A reversed-phase chromatographic separation of the green tea tincture was performed on a commercial C18 column using a gradient of water (containing 0.1% TFA) and ACN. Quantification of EGCG and caffeine was performed by the standard addition method. The amounts of EGCG and caffeine in the tested green tea tincture were each approximately 14 mg mL-1.

Caffeine↗

Particle beam glow discharge mass spectrometry: spectral characteristics of nucleobases.

Use of a particle beam glow discharge (PB-GD) source for mass spectrometric determinations of deoxy- and ribonucleosides and nucleotides is described. Use of this combination of sample introduction and ion source decouples the vaporization and ionization steps, leading to very simple spectral structure. The mass spectra of these compounds are EI-like in nature, with clearly identified molecular ions and fragmentation patterns that are easily rationalized. The PB-GDMS combination can be operated in a flow injection mode wherein the analyte is injected directly into the solvent flow, or can also be coupled to a high-performance liquid chromatography (HPLC) system allowing LC/MS analysis of mixtures. Mass spectra obtained for nucleic acid bases, nucleosides, and nucleotides are readily obtained with injections of low-nanomole quantities. Representative PB-GDMS spectra for deoxy- and ribonucleosides, nucleotides, and mixed-base oligonucleotides are presented to demonstrate the capabilities of the GD source. Characteristic fragmentation peaks from the spectra of adenine, cytosine, guanine, and thymine were identified in 22-base sequences of single-stranded DNA. The PB-GD source is capable of producing spectra that may be used to identify the individual bases present in mixed-base DNA and RNA fragments.

Mass Spectrometry↗