PubMed Health⌕ Search

Biomedical subjects

Jacob Rosen

Publications and source records attributed to Jacob Rosen.

16 recordsLinked to original sources

Generalized approach for modeling minimally invasive surgery as a stochastic process using a discrete Markov model.

Minimally invasive surgery (MIS) involves a multidimensional series of tasks requiring a synthesis between visual information and the kinematics and dynamics of the surgical tools. Analysis of these sources of information is a key step in defining objective criteria for characterizing surgical performance. The Blue DRAGON is a new system for acquiring the kinematics and the dynamics of two endoscopic tools synchronized with the endoscopic view of the surgical scene. Modeling the process of MIS using a finite state model [Markov model (MM)] reveals the internal structure of the surgical task and is utilized as one of the key steps in objectively assessing surgical performance. The experimental protocol includes tying an intracorporeal knot in a MIS setup performed on an animal model (pig) by 30 surgeons at different levels of training including expert surgeons. An objective learning curve was defined based on measuring quantitative statistical distance (similarity) between MM of experts and MM of residents at different levels of training. The objective learning curve was similar to that of the subjective performance analysis. The MM proved to be a powerful and compact mathematical model for decomposing a complex task such as laparoscopic suturing. Systems like surgical robots or virtual reality simulators in which the kinematics and the dynamics of the surgical tool are inherently measured may benefit from incorporation of the proposed methodology.

Computer Simulation↗

Optimization of a spherical mechanism for a minimally invasive surgical robot: theoretical and experimental approaches.

With a focus on design methodology for developing a compact and lightweight minimally invasive surgery (MIS) robot manipulator, the goal of this study is progress toward a next-generation surgical robot system that will help surgeons deliver healthcare more effectively. Based on an extensive database of in-vivo surgical measurements, the workspace requirements were clearly defined. The pivot point constraint in MIS makes the spherical manipulator a natural candidate. An experimental evaluation process helped to more clearly understand the application and limitations of the spherical mechanism as an MIS robot manipulator. The best configuration consists of two serial manipulators in order to avoid collision problems. A complete kinematic analysis and optimization incorporating the requirements for MIS was performed to find the optimal link lengths of the manipulator. The results show that for the serial spherical 2-link manipulator used to guide the surgical tool, the optimal link lengths (angles) are (60 degrees, 50 degrees). A prototype 6-DOF surgical robot has been developed and will be the subject of further study.

Computer-Aided Design↗

Real-time myoprocessors for a neural controlled powered exoskeleton arm.

Exoskeleton robots are promising assistive/rehabilitative devices that can help people with force deficits or allow the recovery of patients who have suffered from pathologies such as stroke. The key component that allows the user to control the exoskeleton is the human machine interface (HMI). Setting the HMI at the neuro-muscular level may lead to seamless integration and intuitive control of the exoskeleton arm as a natural extension of the human body. At the core of the exoskeleton HMI there is a model of the human muscle, the "myoprocessor," running in real-time and in parallel to the physiological muscle, that predicts joint torques as a function of the joint kinematics and neural activation levels. This paper presents the development of myoprocessors for the upper limb based on the Hill phenomenological muscle model. Genetic algorithms are used to optimize the internal parameters of the myoprocessors utilizing an experimental database that provides inputs to the model and allows for performance assessment. The results indicate high correlation between joint moment predictions of the model and the measured data. Consequently, the myoprocessor seems an adequate model, sufficiently robust for further integration into the exoskeleton control system.

Arm↗

Control system architecture for a minimally invasive surgical robot.

As the field of surgical robotics continues to evolve, it is important to keep patient safety in mind. This paper describes a safety control architecture aimed at moving an experimental system in the direction of intrinsically safe operation. The system includes safety features such as: a small number of states, Programmable Logic Controller (PLC) state transition control, active enable, brakes, E-STOP, and a surgeon foot pedal.

Humans↗

Hybrid analysis of a spherical mechanism for a minimally invasive surgical (MIS) robot--design concepts for multiple optimizations.

Several criteria exist for determining the optimal design for a surgical robot. This paper considers kinematic performance metrics, which reward good kinematic performance, and dynamic performance metrics, which penalize poor dynamic performance. Kinematic and dynamic metrics are considered independently, and then combined to produce hybrid metrics. For each metric, the optimal design is the one that maximizes the performance metric over a specific design space. In the case of a 2-DOF spherical mechanism for a surgical robot, the optimal design determined by kinematic metrics is a robot arm with link angles (alpha(12)=90 degrees , alpha(23)=90 degrees ). The large link angles are the most dextrous, but have the greatest risk of robot-robot or robot-patient collisions and require the largest actuators. The link lengths determined by the dynamic metrics are much shorter, which reduces the risk of collisions, but tend to place the robot in singularities much more frequently. When the hybrid metrics are used, and a restriction that the arm must be able to reach a human's entire abdomen, the optimal design is around (alpha(12)=51 degrees, alpha(23)=54 degrees). The hybrid design provides a compromise between dexterity and compactness.

Equipment Design↗

Data mining of the E-pelvis simulator database: a quest for a generalized algorithm for objectively assessing medical skill.

Inherent difficulties in evaluating clinical competence of physicians has lead to the widespread use of subjective skill assessment techniques. Inspired by an analogy between medical procedure and spoken language, proven modeling methods in the field of speech recognition were adapted for use as objective skill assessment techniques. A generalized methodology using Markov Models (MM) was developed. The database under study was collected with the E-Pelvis physical simulator. The simulator incorporates an array of five contact force sensors located in key anatomical landmarks. Two 32-state fully connected MMs are used, one for each skill level. Each state in the model corresponds to one of the possible combinations of the 5 active contact force sensors distributed in the simulator. Statistical distances measured between models representing subjects with different skill levels are sensitive enough to provide an objective measure of medical skill level. The method was tested with 41 expert subjects and 41 novice subjects in addition to the 30 subjects used for training the MM. Of the 82 subjects, 76 were classified correctly (92%). Moreover, unique state transitions as well as force magnitudes for corresponding states (expert/novice) were found to be skill dependent. Given the white box nature of the model, analyzing the MMs provides insight into the examination process performed. This methodology is independent of the modality under study. It was previously used to assess surgical skill in a minimally invasive surgical setup using the Blue DRAGON, and it is currently applied to data collected using the E-Pelvis.

Algorithms↗

Spherical mechanism analysis of a surgical robot for minimally invasive surgery -- analytical and experimental approaches.

Recent advances in technology have led to the fusion of MIS techniques and robot devices. However, current systems are large and cumbersome. Optimizing the surgical robot mechanism will eventually lead to its integration into the operating room (OR) of the future becoming the extended presence of the surgeon and nurses in a room occupied by the patient alone. By optimizing a spherical mechanism using data collected in-vivo during MIS procedures, this study is focused on a bottom-up approach to developing a new class of surgical robotic arms while maximizing their performance and minimizing their size. The spherical mechanism is a rotational manipulator with all axes intersecting at the center of the sphere. Locating the rotation center of the mechanism at the MIS port makes this class of mechanism a suitable candidate for the first two links of a surgical robot for MIS. The required dexterous workspace (DWS) is defined as the region in which 95% of the tool motions are contained based on in-vivo measurements. The extended dexterous workspace (EDWS) is defined as the entire abdominal cavity reachable by a MIS instruments. The DWS is defined by a right circular cone with a vertex angle of 60 degrees and the EDWS is defined by a cone with an elliptical cross section created by two orthogonal vertex angles of 60 degrees and 90 degrees. A compound function based on the mechanism's isotropy and the mechanism stiffness was considered as the performance metric cost function. Optimization across both the DWS and the EDWS lead to a serial mechanism configuration with link length angles of 74 degrees and 60 degrees for a serial configuration. This mechanism configuration maximized the kinematic performance in the DWS while keeping the EDWS as its reachable workspace. Surgeons, using a mockup of two mechanisms in a MIS setup, validated these results experimentally. From these experiments the serial configuration was deemed most applicable for MIS robotic applications compared to a parallel mechanism configuration. The mechanical design of a cable actuated surgical robot was based on optimized link length angles. The system is currently being integrated into a fully operated two-arm system. Small form-factor surgical robotic arms with optimized dexterous workspaces will facilitate the integration of multiple arms while avoiding self-collision in the OR of the future.

Robotics↗

Quantifying surgeon grasping mechanics in laparoscopy using the Blue DRAGON system.

Mechanical testing of abdominal organs has a profound impact on surgical simulation and surgical robotics development. Due to the nonlinear and viscoelastic nature of soft tissue it is crucial to test them in surgically relevant ranges of applied force, deformation, and duration for incorporating haptic realism into surgical simulators and for safe operation of surgical robots. In order to determine these ranges, a system known as the Blue DRAGON was used to track the motions and the forces applied to surgical tools during live procedures for quantifying how surgeons typically perform a minimally invasive surgical procedure. Thirty-one surgeons of varying skill were recorded performing three different surgical tasks. Grasping force (as applied to the tool handles) and handle angle for each tool were the signals of interest among 26 channels total acquired by the system in real time. These data were analyzed for their magnitudes and frequency content. Using the tool contact state, an algorithm selected tissue grasps to analyze measures during grasps only, as well as obtain grasp durations. The mean force applied to the tool handles during tissue grasps was 8.52 N +/- 2.77 N; maximum force was 68.17 N. Ninety-five percent of the handle angle frequency content was below 1.98 Hz +/- 0.98 Hz. Average grasp time was 2.29 s +/- 1.65 s, and 95% of all grasps were held for 8.86 s +/- 7.06 s or less. The average maximum grasp time during these tasks was 13.37 s +/- 11.42 s. These results form the basis for determining how abdominal tissues are to be mechanically tested in ranges and durations of force and deformation that are surgically realistic. Additionally, this information may serve as design specifications for new surgical robots or haptic simulators.

Animals↗

Optimization of a vector quantization codebook for objective evaluation of surgical skill.

Surgical robotic systems and virtual reality simulators have introduced an unprecedented precision of measurement for both tool-tissue and tool-surgeon interaction; thus holding promise for more objective analyses of surgical skill. Integrative or averaged metrics such as path length, time-to-task, success/failure percentages, etc., have often been employed towards this end but these fail to address the processes associated with a surgical task as a dynamic phenomena. Stochastic tools such as Markov modeling using a 'white-box' approach have proven amenable to this type of analysis. While such an approach reveals the internal structure of the of the surgical task as a process, it requires a task decomposition based on expert knowledge, which may result in a relatively large/complex model. In this work, a 'black box' approach is developed with generalized cross-procedural applications., the model is characterized by a compact topology, abstract state definitions, and optimized codebook size. Data sets of isolated tasks were extracted from the Blue DRAGON database consisting of 30 surgical subjects stratified into six training levels. Vector quantization (VQ) was employed on the entire database, thus synthesizing a lexicon of discrete, task-independent surgical tool/tissue interactions. VQ has successfully established a dictionary of 63 surgical code words and displayed non-temporal skill discrimination. VQ allows for a more cross-procedural analysis without relying on a thorough study of the procedure, links the results of the black-box approach to observable phenomena, and reduces the computational cost of the analysis by discretizing a complex, continuous data space.

Algorithms↗

Modeling the human body/seat system in a vibration environment.

The vibration environment is a common man-made artificial surrounding with which humans have a limited tolerance to cope due to their body dynamics. This research studied the dynamic characteristics of a seated human body/seat system in a vibration environment. The main result is a multi degrees of freedom lumped parameter model that synthesizes two basic dynamics: (i) global human dynamics, the apparent mass phenomenon, including a systematic set of the model parameters for simulating various conditions like body posture, backrest, footrest, muscle tension, and vibration directions, and (ii) the local human dynamics, represented by the human pelvis/vibrating seat contact, using a cushioning interface. The model and its selected parameters successfully described the main effects of the apparent mass phenomenon compared to experimental data documented in the literature. The model provided an analytical tool for human body dynamics research. It also enabled a primary tool for seat and cushioning design. The model was further used to develop design guidelines for a composite cushion using the principle of quasi-uniform body/seat contact force distribution. In terms of evenly distributing the contact forces, the best result for the different materials and cushion geometries simulated in the current study was achieved using a two layer shaped geometry cushion built from three materials. Combining the geometry and the mechanical characteristics of a structure under large deformation into a lumped parameter model enables successful analysis of the human/seat interface system and provides practical results for body protection in dynamic environment.

Computer Simulation↗

In-vivo and in-situ compressive properties of porcine abdominal soft tissues.

Accurate biomechanical characteristics of tissues are essential for developing realistic virtual reality surgical simulators utilizing haptic feedback. Surgical simulation technology has progressed rapidly but lacks a comprehensive database of soft tissue mechanical properties with which to incorporate. Simulators are often designed purely based on what "feels right;" quantitative empirical data are lacking. A motorized endoscopic grasper was used to test abdominal porcine tissues in-vivo and in-situ with cyclic and static compressive loadings. An exponential constitutive equation was fit to the resulting stress-strain curves, and the coefficients were compared for various conditions. Stress relaxation for liver and small bowel were also examined. Differences between successive squeezes and between in-vivo and in-situ conditions were found.

Abdomen↗

Minimally invasive surgery task decomposition--etymology of endoscopic suturing.

The analogy between Minimally Invasive Surgery (MIS) and the human language inspires the decomposition of a surgical task into its primary elements. The frequency of different elements or words" and their sequential associations or "grammar" both hold critical information about the process and outcome of the procedure. Modeling these sequential element expressions using a multi finite states model (Markov model) reveals the grammatical structure of the surgical task and is utilized as one of the key steps in objectively assessing surgical performance. The experimental protocol included 30 surgeons at different levels of training (5xR1,R2,R3,R4,R5, and experts) performing Laparoscopic suturing on an animal model (pig). The kinematics and dynamics of left and right endoscopic tools along with the visual view of the surgical scene were acquired by the Blue DRAGON system. The methodology of decomposing the surgical task is based on a fully connected, finite-states (30 states) Markov model (MM) where the left and right hands are represented by 15 states each. In addition to the MM objective analysis, a scoring protocol was used by an expert surgeon to subjectively assess the subjects' technical performance. An objective learning curve was defined based on measuring quantitative statistical distance (similarity) between MM of experts and MM of residents at different levels of training. The objective learning curve (e.g. statistical distance between MM) was similar to that of the subjective performance analysis. The MM proved to be a powerful and compact mathematical model for decomposing a complex task such as laparoscopic suturing. Systems like surgical robots or virtual reality simulators that inherently measure the kinematics and dynamics of the surgical tool may benefit from inclusion of the proposed methodology for analysis of efficacy and objective evaluation of surgical skills during training.

Endoscopy↗

Task decomposition of laparoscopic surgery for objective evaluation of surgical residents' learning curve using hidden Markov model.

OBJECTIVE: Evaluation of the laparoscopic surgical skills of surgical residents is usually a subjective process carried out in the operating room by senior surgeons. The two hypotheses of the current study were: (1) haptic information and tool/tissue interactions (types and transitions) performed in laparoscopic surgery are skill-dependent, and (2) statistical models (Hidden Markov Models--HMMs) incorporating these data are capable of objectively evaluating laparoscopic surgical skills. MATERIALS AND METHODS: Eight subjects (six residents--two first-year (R1), two third-year (R3), and two fifth-year (R5)--and two expert laparoscopic surgeons) performed laparoscopic cholecystectomy on pigs using an instrumented grasper equipped with force/torque (F/T) sensors at the hand/tool interface, and F/T data was synchronized with video of the operative maneuvers. Fourteen types of tool/tissue (T/T) interactions, each associated with unique F/T signatures, were defined from frame-by-frame video analysis. HMMs for each subject and step of the operation were compared to evaluate the statistical distance between expert surgeons and residents with different skill levels. RESULTS: The statistical distances between HMMs representing expert surgeons and residents were significantly different (alpha < 0.05). Major differences occurred in: (1) F/T magnitudes; (2) type of T/T interactions and transitions between them; and (3) time intervals for each T/T interaction and overall completion time. The greatest difference in performance was between R1 (junior trainee) and R3 (midlevel trainee). Smaller changes were seen as expertise increased beyond the R3 level. CONCLUSION: HMMs incorporating haptic and visual information provide an objective tool for evaluating surgical skills. Objective evidence for a "learning curve" suggests that surgical residents acquire a major portion of their laparoscopic skill between year 1 and year 3 of training.

Animals↗

Computer-controlled motorized endoscopic grasper for in vivo measurement of soft tissue biomechanical characteristics.

Accurate biomechanical characteristics of tissues are essential for developing realistic virtual reality surgical simulators utilizing haptic devices. Surgical simulation technology has progressed rapidly but without a large database of soft tissue mechanical properties with which to incorporate. The device described here is a computer-controlled, motorized endoscopic grasper capable of applying surgically relevant levels of force to tissue in vivo and measuring the tissue's force-deformation properties.

Abdomen↗

The Blue DRAGON--a system for monitoring the kinematics and the dynamics of endoscopic tools in minimally invasive surgery for objective laparoscopic skill assessment.

Minimally invasive surgeiy (MIS) involves a multi-dimensional series of tasks requiring a synthesis between visual information and the kinematics and dynamics of the surgical tools. Analysis of these sources of information is a key step in mastering MIS surgery but may also be used to define objective criteria for characterizing surgical performance. The BIueDRAGON is a new system for acquiring the kinematics and the dynamics of two endoscopic tools along with the visual view of the surgical scene. It includes two four-bar mechanisms equipped with position and force torque sensors for measuring the positions and the orientations (P/O) of two endoscopic tools along with the forces and torques applied by the surgeons hands. The methodology of decomposing the surgical task is based on a fully connected, finite-states (28 states) Markov model where each states corresponded to a fundamental tool/tissue interaction based on the tool kinematics and associated with unique F/T signatures. The experimental protocol included seven MIS tasks performed on an animal model (pig) by 30 surgeons at different levels of their residency training. Preliminary analysis of these data showed that major differences between residents at different skill levels were: (i) the types of tool/tissue interactions being used, (ii) the transitions between tool/tissue interactions being applied by each hand, (iii) time spent while perfonning each tool/tissue interaction, (iv) the overall completion time, and (v) the variable F/T magnitudes being applied by the subjects through the endoscopic tools. Systems like surgical robots or virtual reality simulators that inherently measure the kinematics and the dynamics of the surgical tool may benefit from inclusion of the proposed methodology for analysis of efficacy and objective evaluation of surgical skills during training.

Animals↗