PubMed Health⌕ Search

Biomedical subjects

Jacobus Kuijt

Publications and source records attributed to Jacobus Kuijt.

2 recordsLinked to original sources

Laser-induced quenched phosphorescence detection in capillary electrophoresis.

The feasibility of laser-based excitation for quenched phosphorescence detection in capillary electrophoresis (CE) was explored for the first time by using a small-size, quadrupled Nd-YAG laser emitting 266 nm pulses (duration, 0.4 ns) at a repetition rate of 7.8 kHz. To provide a continuous phosphorescence background, the phosphorophore 1-bromo-4-naphthalene sulfonic acid (BrNS) was added to the separation buffer. Both experiments and theory show that in laser-induced phosphorescence (LIP) - in contrast with lamp-excited phosphorescence - one normally deals with such high triplet-state phosphorophore concentrations that triplet-triplet annihilation is the major deactivation pathway. This results in a lower quantum yield of the analyte-induced bimolecular quenching interaction and, thus, the observed quenching signal. The situation can be improved by using a cylindrical lens for excitation in order to reduce the irradiance. In this case limits of detection (LODs) similar to those obtained using lamp excitation (1x10(-8) M) were achieved, while the width of the detection window was reduced from about 4 mm to 1 mm. Even under exclusion of triplet-triplet annihilation, i.e., under conditions of low irradiance, for our setup the quenching yields in LIP were smaller than in lamp-based phosphorescence detection. This is due to the repetition rate of the laser (7.8 kHz), which is too high in view of the phosphorescence lifetime (ca. 300 micros at low irradiance). Theory shows that this disadvantageous effect will be fully eliminated if the repetition rate is decreased to 1 kHz.

Electrons↗

Quenched phosphorescence detection in cyclodextrin-based electrokinetic chromatography.

Quenched phosphorescence detection is a sensitive detection method recently introduced in capillary zone electrophoresis. It is based on the dynamic quenching interaction of the analytes (quenchers) with a phosphorophore, 1-bromo-4-naphthalenesulfonate (BrNS), present in the separation buffer. In this study, it is shown that this detection method can also be used in cyclodextrin-based electrokinetic chromatography (CD-EKC) despite the presence in the buffer solution of cyclodextrins, which are known to reduce the luminescence quenching rate constants. Experiments indicate that BrNS mainly resides in the aqueous phase, while the analytes are distributed between both phases. In principle, the observed quenching might arise from the interaction of BrNS with uncomplexed as well as complexed analytes. However, from the dependence of the fractional quenching on the capacity factor (the normalized fractional quenching was found to be equal to the fraction of analyte in the aqueous phase), it was concluded that only aqueous-phase quenching contributes significantly to the observed quenching. Nevertheless, separation and detection can be regarded as fully compatible, because the capacity factors encountered in CD-EKC are generally low (in this study they ranged from about 0.1 to 2.5). Indeed, with nitroaromatic compounds as the target analytes, limits of detection in the 10(-8) M range were achieved.

Journal Article↗