PubMed Health⌕ Search

Biomedical subjects

Jacques Clementy

Publications and source records attributed to Jacques Clementy.

At least 19 recordsLinked to original sources

Dynamic ventricular dyssynchrony: an exercise-echocardiography study.

OBJECTIVES: We sought to assess the effects of exercise on ventricular dyssynchrony in patients with normal and depressed left ventricular (LV) function. BACKGROUND: Asynchronous myocardial contraction adversely influences ventricular function and is associated with a poor prognosis in heart failure. Exercise-induced changes in ventricular dyssynchrony may be an important determinant of dynamic changes in cardiac output and mitral regurgitation. METHODS: A total of 65 consecutive heart failure patients and 50 matched healthy control patients underwent exercise echocardiography. Conventional and tissue Doppler parameters were measured before and during symptom-limited exercise. Left ventricular dyssynchrony was defined as the standard deviation of 12 LV segmental electromechanical delays. Analysis of the control group allowed delimitation of normal cutoff values. RESULTS: In patients with normal left ventricular function, exercise did not modify the extent of LV asynchrony. In contrast, in heart failure patients, LV dyssynchrony increased by at least 20% in 34%, remained stable in 37%, and decreased by at least 20% in 29%. Moreover, 26% of heart failure patients had either exercise induction or normalization of ventricular dyssynchrony. A significant association was found between exercise-induced changes in dyssynchrony and the presence of ischemic cardiomyopathy (p < 0.05). Rest-exercise differences in ventricular dyssynchrony were correlated with changes in cardiac output and mitral regurgitation (r = -0.63 and 0.56, respectively). CONCLUSIONS: In heart failure patients, exercise can alter the magnitude of ventricular dyssynchrony. Some patients have a response to exertion with induction of ventricular dyssynchrony, whereas others show normalization. Changes in ventricular dyssynchrony during exercise correlate with alterations in cardiac output and mitral regurgitation.

Aged↗

Echocardiographic assessment during exercise of heart failure patients with cardiac resynchronization therapy.

This prospective echocardiographic study investigated the respective impacts of left ventricular (LV) pacing and simultaneous and sequential biventricular pacing (BVP) on ventricular dyssynchrony during exercise in 23 patients with compensated heart failure and ventricular conduction delays. During exercise, LV pacing and BVP significantly (p <0.05) improved mitral regurgitation and LV dyssynchrony compared with spontaneous activation. LV segmental electromechanical delays were significantly prolonged during LV pacing, leading to increased systolic time (p <0.05), decreased LV filling time (p <0.05), and decreased stroke volume (p <0.05) compared with BVP. After optimization of the interventricular delay with sequential BVP, additional benefit was obtained during exercise in terms of stroke volume and mitral regurgitation (p <0.05). The optimal interventricular delay was different at rest and during exercise in 57% of the patients. Changes from at rest to exercise in LV dyssynchrony were correlated with changes in stroke volume (r = -0.61, p <0.01) and changes in mitral regurgitation (r = 0.60, p <0.01).

Cardiac Pacing, Artificial↗

Long-term evaluation of atrial fibrillation ablation guided by noninducibility.

BACKGROUND: Pulmonary vein (PV) isolation and linear lesions are effective in eliminating paroxysmal atrial fibrillation (AF), but linear lesions probably are not required in all patients. Noninducibility of AF has been shown to be associated with freedom from arrhythmia in 87% of patients. OBJECTIVES: The purpose of this study was to prospectively evaluate the role of noninducibility in guiding a stepwise approach tailored to the patient. METHODS: In 74 patients (age 53 +/- 8 years) with paroxysmal AF, PV isolation was performed during induced or spontaneous AF. If AF was inducible after PV isolation, one to two additional linear lesions were placed at the mitral isthmus and/or left atrial roof, with the endpoint of noninducibility of AF or atrial flutter. Inducibility (AF/atrial flutter, lasting > or = 10 minutes) was assessed using burst pacing at an output of 20 mA down to refractoriness from the coronary sinus and both atrial appendages. RESULTS: In 42 patients (57%), PV isolation restored sinus rhythm and rendered AF noninducible. In the 32 patients with persistent or inducible AF after PV isolation, a single linear lesion achieved noninducibility in 20, whereas two linear lesions were required in 12 and resulted in conversion to sinus rhythm and noninducibility in 10. Using this stepwise approach, a total of 69 patients (93%) were rendered noninducible. During follow-up of 18 +/- 4 months, 67 patients (91%) were free from arrhythmia without antiarrhythmic drugs. Repeat procedures were performed in 23 patients: repeat ablation was required to consolidate prior targets in 15 patients (20%), and "new" linear lesions, which were not predicted by inducibility during the index procedure, were required in 8 (11%). CONCLUSION: Noninducibility can be used as an endpoint for determining the subset of patients with paroxysmal AF who require additional linear lesions after PV isolation. This tailored approach is effective in 91% of patients while preventing delivery of unnecessary linear lesions.

Anticoagulants↗

Reverse remodeling of the left cardiac chambers after catheter ablation after 1 year in a series of patients with isolated atrial fibrillation.

BACKGROUND: Isolated atrial fibrillation (AF) is associated with mild enlargement of the left atrium (LA) and left ventricular (LV) diastolic dysfunction. The impact of ablation of isolated AF on left chamber size and function is unclear, and whether diastolic dysfunction is the cause or the consequence of AF remains unknown. The objective of this prospective study was to evaluate the impact of sinus rhythm restoration by catheter ablation on LV diastolic dysfunction, LA morphology, and mechanical function. METHODS AND RESULTS: Forty-eight patients with isolated AF were studied by serial echocardiographic studies at baseline and at 1-, 3-, 6-, 9-, and 12-month intervals after radiofrequency ablation. LA dimensions and mechanical function and LV systolic and diastolic functions were evaluated at each time interval. Diastolic function was assessed with conventional Doppler parameters and new indexes such as tissue Doppler imaging, mitral flow propagation velocity, and combined criteria. LV diastolic dysfunction was present in paroxysmal and chronic AF patients with a reduction of tissue Doppler imaging lateral early diastolic peak velocity in 37% (P<0.001) and 48% (P<0.01), respectively, compared with healthy control subjects. At the end of the follow-up, LA area decreased significantly by 18% (P<0.001) in paroxysmal and 23% (P<0.05) in chronic AF patients. Diastolic function improved significantly with an increase in lateral early diastolic peak velocity of 29% (P<0.001) in paroxysmal AF and 46% (P<0.05) in chronic AF patients. A significant increase in LV ejection fraction was also noted for both groups: 7.7% and 18.8%, respectively. CONCLUSIONS: This study demonstrates reverse morphological remodeling of the LA and improvement of LV diastolic and systolic functions after restoration of sinus rhythm by ablation for isolated AF. Because patients with isolated AF have none of the traditional causes of LV diastolic dysfunction, our findings suggest that AF may be partly the cause rather than the consequence of diastolic dysfunction.

Adult↗

Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system.

AIMS: Catheter ablation of atrial fibrillation (AF) is centred on pulmonary vein (PV) ablation with or without additional atrial substrate modification. These procedures may be prolonged with significant fluoroscopy exposure. This study evaluates a new non-fluoroscopic navigation system during ablation of AF. METHODS AND RESULTS: Seventy-two patients undergoing catheter ablation of symptomatic drug refractory AF were prospectively randomized to ablation with (n=35; study group) or without (n=37; control group) non-fluoroscopic navigation. PV isolation was performed in all patients. In patients with persistent or inducible sustained AF after PV isolation linear ablation was performed by joining the superior PVs. PV isolation was achieved in all patients; fluoroscopy (15.4+/-3.4 vs. 21.3+/-6.4 min; P<0.001) and procedural (52+/-12 vs. 61+/-17 min; P=0.02) durations were significantly reduced in the study group. Linear block was achieved in 37 of the 39 patients; with a significant reduction in fluoroscopy (5.6+/-2.2 vs. 9.9+/-4.8 min; P=0.003) and procedural (14.7+/-5.5 vs. 26.6+/-16.9 min; P=0.007) durations in the study group. After a follow-up of 6.9+/-2.9 months (range 3-10), 26 (74%) patients in the non-fluoroscopic navigation group and 29 (78%) patients in the control group were arrhythmia-free after the first procedure. CONCLUSION: This prospectively randomized study demonstrates significant reduction of fluoroscopy exposure and procedural duration using supplementary non-fluoroscopic imaging system for AF ablation.

Adult↗

Arterial stiffness evaluated by measurement of the QKD interval is an independent predictor of cardiovascular events.

BACKGROUND: The QKD interval is the time between the QRS wave on the electrocardiogram (ECG) and the detection of the last Korotkoff sound during BP measurement. Measurement of the QKD interval during ambulatory blood pressure (BP) monitoring provides an automatic evaluation of arterial stiffness. The objective of this longitudinal study was to examine the relationship between arterial stiffness assessed by this method and the occurrence of cardiovascular complications in a cohort of initially untreated hypertensive patients. METHODS: The initially untreated hypertensive patients were included in the cohort of hypertensives recruited to our center between January 1992 and December 1999. All benefited from ambulatory measurement of the QKD interval and BP over 24 h. Most of these patients were given antihypertensive treatment and were followed up by their family physicians, who were unaware of the QKD results. Their outcome was evaluated in 2003 by inquiring of the patients themselves or of their family physicians. RESULTS: The initial population comprised 412 patients. At the end point, 33 had been lost to follow-up. We recorded 49 cardiovascular events in this population with an average follow up of 65 +/- 36 months. In a Cox model, the arterial stiffness assessed by the QKD(100-60) as a percentage of the height-predicted normal value was significantly associated with the occurrence of cardiovascular complications, independent of age and mean 24-h BP. CONCLUSIONS: This study using ambulatory measurement of the QKD interval showed that an increase in arterial stiffness was a marker of cardiovascular risk. We show for the first time that its value persists after taking account of the mean systolic pressure over 24 h.

Aged↗

Correlation of atrial electrocardiographic amplitude with radiofrequency energy required to ablate cavotricuspid isthmus-dependent atrial flutter.

OBJECTIVES: The purpose of this study was to evaluate a possible correlation between atrial ECG amplitude in common atrial flutter (AFL) and radiofrequency (RF) energy required to achieve cavotricuspid isthmus block. BACKGROUND: The amount of RF delivery required for ablation of typical AFL is variable. This variation has been attributed to the cavotricuspid isthmus anatomy. Atrial ECG amplitude can be a marker of atrial anatomic variations and therefore may correlate with RF duration required to achieve cavotricuspid isthmus block. METHODS: Seventy consecutive patients were prospectively studied. Ablation of the cavotricuspid isthmus was performed by creating a line of block between the inferior tricuspid annulus and the inferior caval vein using 8-mm-tip electrode catheters. If more than 20 minutes of RF time was required to achieve conduction block, the catheter was changed to an irrigated-tip catheter. Atrial ECG amplitude was assessed in leads II, III, aVF, and aVL. RESULTS: A total of 14 +/- 11 minutes of RF energy was delivered to achieve block in all patients; 12 patients (8%) required more than 20 minutes. Atrial ECG amplitude showed highly significant correlations with cumulative RF energy (F and P waves in lead II: r = 0.703 and r = 0.737, P < .001). P-wave amplitude <0.2 mV and/or flutter wave amplitude <0.35 mV in lead II have a high negative predictive value to predict <20 min RF delivery (96% and 89% respectively). CONCLUSIONS: A significant correlation exists between atrial ECG amplitude and amount of RF required to ablate typical AFL. Atrial ECG amplitude may be a surrogate marker of characteristics of isthmus anatomy. These findings may influence the choice of catheter used for cavotricuspid isthmus ablation.

Aged↗

Potential cost savings by telemedicine-assisted long-term care of implantable cardioverter defibrillator recipients.

Home monitoring (HM) of cardioverter defibrillators (ICD) with its automated wireless remote data access, may decrease the rate of patient visits. This study examined the potential cost savings for the long-term care of ICD assisted by HM. A French database including 502 patients from 6 university hospitals was used. Costs of conventional follow-up (FU) of ICD were calculated without, and compared with the expected cost of FU with HM. Calculations included number of visits, including physician's fees, electrocardiograms, and specific ICD surveillance, and transportation costs. The mean distance between home and institutions performing follow-ups was 69 +/- 57 km. For each visit, a mean overall cost of 215 dollars was calculated, including 121 dollars for transportation and 94 dollars for medical services. HM may obviate up to 2 visits per year. Over the 5 years of expected life of the device, the decrease in costs for FU visits was estimated at 2,149 dollars. With an additional cost of 1,200 dollars for the HM system, saving began after a mean FU of 33.5 months. The time to onset of cost saving by HM ranged between 17.4 months for patients living >150 km from the medical facility to 52.2 months for those living <50 km away. It is concluded that the HM may considerably reduce the overall costs of ICD FU by saving on transportation cost, particularly when the distance between home and medical facility is >100 km.

Cost Savings↗

Clinical predictors of noninducibility of sustained atrial fibrillation after pulmonary vein isolation.

BACKGROUND: Noninducibility of sustained atrial fibrillation (AF) after pulmonary vein isolation (PVI) has been shown to be associated with a better clinical outcome. We evaluated the role of clinical variables that could predict noninducibility of sustained AF after PVI. METHODS AND RESULTS: Data were collected prospectively from 181 patients (153 male; age 54 +/- 9 years) referred for ablation of drug-refractory symptomatic paroxysmal AF (duration < or =7 days). Clinical variables were evaluated with regard to their ability of predicting noninducibility of sustained AF (< or =10 minutes) after PVI. Univariate analysis was performed on all collected variables followed by multivariate analysis for variables showing a P value <0.1. After PVI, sustained AF was noninducible in 97 (54%) patients. The following clinical variables showed a significant difference between the groups: body weight, longest AF episode, duration of AF history, presence or absence of structural heart disease, left ventricular (LV) hypertrophy, prior cardioversion, left atrial (LA) parasternal, and longitudinal diameters and LV diameters. On multivariate analysis, three independent predictors of noninducibility were identified: a shorter duration of AF episodes (AF <12 hours: RR 0.01 (0.002-0.06), P < 0.001; AF 12-48 hours: RR 0.07 (0.01-0.37), P = 0.001); LA longitudinal diameter <57 mm (RR 0.33 (0.13-0.82), P = 0.016); and absence of LV hypertrophy (RR 0.15 (0.04-0.63), P = 0.01). CONCLUSIONS: Shorter AF episodes, smaller LA longitudinal diameter, and absence of LV hypertrophy are independent predictors of noninducibility of sustained AF after PVI.

Adult↗

[Catheter ablation for atrial fibrillation].

Atrial fibrillation, the most common cardiac arrhythmia, is frequently disabling and drug-resistant, and can be associated with major complications such as thromboembolic events. Non drug approaches, including surgery and catheter-based ablation, are used to treat the most severely symptomatic patients. These new treatment strategies have drastically improved our knowledge of the pathophysiology of this arrhythmia and, importantly, have shown that atrial fibrillation is curable. Since 1994, two main approaches have been used to modify the substrate responsible for AF maintenance, namely the creation of linear lesions, and ablation of triggers located within the pulmonary veins (about 90% of cases). Most teams worldwide now use approaches centered on PV isolation, which, although imperfect, are sufficiently effective to be offered routinely to selected patients in experienced centers. The importance of PVs in the initiation of AF has been clearly demonstrated, and there is also evidence of a role in AF maintenance. However, the existence of non venous foci or a prominent substrate for AF maintenance limits the success rate to about 70%. We are now using a combination of PV isolation and a linear lesion delivered to the mitral isthmus, from the mitral annulus to the ostium of the left inferior pulmonary vein. This more complex procedure carries a significantly higher success rate, about 82% of patients being cured and drug-free. The main problem is to identify patients requiring mitral isthmus ablation in addition to PV isolation. At present, AF ablation is restricted to symptomatic patients in whom at least two antiarrhythmic drugs have failed, but future technical improvements are likely to broaden the indications of ablation therapy for AF.

Atrial Fibrillation↗

Echocardiographic parameters of ventricular dyssynchrony validation in patients with heart failure using sequential biventricular pacing.

OBJECTIVES: We sought to evaluate the relationship between hemodynamic and ventricular dyssynchrony parameters in patients undergoing simultaneous and sequential biventricular pacing (BVP). BACKGROUND: Various echocardiographic parameters of ventricular dyssynchrony have been proposed to screen and optimize BVP therapy. METHODS: Forty-one patients with heart failure undergoing BVP implantation were studied. Echocardiography coupled with tissue tracking and pulsed Doppler tissue imaging (DTI) was performed before and after BVP implantation and after three months of optimized BVP. Indexes of inter- or intraventricular dyssynchrony were correlated with hemodynamic changes during simultaneous and sequential BVP (10 intervals of right ventricular [RV] or left ventricular [LV] pre-excitation). RESULTS: Variations in intra-LV delay(peak), intra-LV delay(onset), and index of LV dyssynchrony measured by pulsed DTI were highly correlated with those of cardiac output (r = -0.67, r = -0.64, and r = -0.67, respectively; p < 0.001) and mitral regurgitation (r = 0.68, r = 0.63, and r = 0.68, respectively; p < 0.001), whereas variations in the extent of myocardium displaying delayed longitudinal contraction (r = -0.48 and r = 0.51, respectively; p < 0.05) and the variations in septal-to-posterior wall motion delay (r = -0.41, p < 0.05 and r = 0.24, p = NS, respectively) were less correlated. The changes in interventricular dyssynchrony were not significantly correlated (p = NS). Compared with simultaneous BVP, individually optimized sequential BVP significantly increased cardiac output (p < 0.01), decreased mitral regurgitation (p < 0.05), and improved all parameters of intra-LV dyssynchrony (p < 0.01). At three months, a significant reverse mechanical LV remodeling was observed with significantly decreased LV volumes (p < 0.01) associated with an increased LV ejection fraction (p = 0.035). CONCLUSIONS: Specific echocardiographic measurements of ventricular dyssynchrony are highly correlated with hemodynamic changes and may be a useful adjunct in the selection and optimization of BVP. Individually optimized sequential BVP provided a significant early hemodynamic improvement compared with simultaneous BVP.

Aged↗

Detrimental ventricular remodeling in patients with congenital complete heart block and chronic right ventricular apical pacing.

BACKGROUND: Although dual-chamber pacing improves cardiac function in patients with complete congenital atrioventricular block (CCAVB) by restoring physiological heart rate and atrioventricular synchronization, the long-term detrimental effect of asynchronous electromechanical activation induced by apical right ventricular pacing (RVP) has not been well clarified. METHODS AND RESULTS: Twenty-three CCAVB adults (24+/-3 years) with a DDD transvenous pacemaker underwent conventional echocardiography before implantation and, after at least 5 years of RVP, an exercise test and echocardiography coupled with tissue Doppler imaging and tissue tracking. They were compared with 30 matched healthy control subjects. After 10+/-3 years of RVP, CCAVB adults had significantly higher values versus controls in terms of intra-left ventricular (LV) asynchrony (respectively, 59+/-18 versus 19+/-9 ms, P<0.001), extent of LV myocardium displaying delayed longitudinal contraction (39+/-15% versus 10+/-7%, P<0.01), and septal-to-posterior wall-motion delay (84+/-26 versus 18+/-9 ms, P<0.01). The ratio of late-activated posterior to early-activated septal wall thickness was higher after long-term RVP than before (1.3+/-0.2 vs 1+/-0.1, P=0.05) and was higher than in controls (1+/-0.1, P<0.05). The percentage of patients with increased LV end-diastolic diameter was higher after long-term RVP than before implantation and was higher than in controls (57% versus 13%, P<0.05, and 57% versus 0%, P<0.01, respectively). CCAVB patients with long-term RVP had a lower cardiac output than controls (3.8+/-0.6 versus 4.9+/-0.8 L/min, P<0.05) and lower exercise performance (123+/-24 versus 185+/-39 W, P<0.001). CONCLUSIONS: Prolonged ventricular dyssynchrony induced by long-term endovenous RVP is associated with deleterious LV remodeling, LV dilatation, LV asymmetrical hypertrophy, and low exercise capacity. These new data highlight the importance of the ventricular activation sequence in all patients with chronic ventricular pacing.

Adult↗

Improvement of left ventricular wall synchronization with multisite ventricular pacing in heart failure: a prospective study using Doppler tissue imaging.

UNLABELLED: We sought to assess right, left and biventricular pacing effects on myocardial function by using pulsed-Doppler tissue imaging (DTI) and automated border detection (ABD) techniques which provide electromechanical delay (EMD) assessment of the different left ventricular walls. METHODS: 15 patients (67+/-7 years) with drug-resistant primitive dilated cardiomyopathy and QRS> or =140 ms received a pacemaker for multisite ventricular pacing. Echocardiography was performed after 1 month of biventricular pacing (BVP). Echocardiographic measurements were recorded during spontaneous rhythm (SpR), right ventricular pacing (RVP), left ventricular pacing (LVP) and BVP. RESULTS: LV ejection fraction was statistically similar between the four rhythms. BVP showed a significant EMD decrease for the lateral LV wall vs. SpR, RVP and even LVP. LVP resulted in significantly longer aortic pre-ejection time vs. BVP while the EMD temporal dispersion (time between the shortest regional EMD and the longest one) was similar in the two modes. CONCLUSIONS: BVP and LVP substantially reduce the EMD temporal dispersion of the four LV walls, but with a longer aortic pre-ejection time for LVP. In RVP, LVP and BVP, the septal LV wall is always activated later than during SpR. BVP and LVP are associated with a mitral regurgitation reduction.

Aged↗

Intra-left ventricular electromechanical asynchrony. A new independent predictor of severe cardiac events in heart failure patients.

OBJECTIVES: We sought to assess the electromechanical parameters, using tissue Doppler echocardiography, as potential independent predictors of heart failure (HF) worsening. BACKGROUND: Ventricular conduction disorders worsen the prognosis for HF patients. However, the relationships between the QRS width and morphology, hemodynamic parameters, and presence and magnitude of intra-left ventricular (LV) and inter-ventricular (V) asynchrony have not been well clarified. METHOD: A total of 104 patients with an LV ejection fraction (EF) </=45% and stabilized HF, without myocardial infarction (MI), underwent echocardiography coupled with tissue Doppler imaging and were followed for one year. The protocol analyzed the incidence of worsening HF (hospitalization for cardiac decompensation). Inter-V and regional electromechanical delays for the anterior, septal, inferior, and lateral LV walls were correlated with the QRS morphology and duration. The intra-LV and inter-V asynchrony values of these patients were compared with those of healthy subjects matched by gender and age criteria to determine the respective normal ranges. RESULTS: The presence of intra-LV (but not inter-V) asynchrony was identified as an independent predictor of severe cardiac events (hazard ratio 3.39, p < 0.0001), independent of the LVEF and QRS width. Of patients with a QRS width <120 ms (55%; n = 57), 56% presented with major intra-LV asynchrony and 12% with inter-V asynchrony. Intra-LV asynchrony was observed in 84% of left bundle branch block patients, but also in 83% of right bundle branch block patients (p = NS). There was a poor correlation between the QRS width and intra-LV or inter-V asynchrony (r = 0.36, p = NS and r = 0.43, p = 0.05, respectively). CONCLUSIONS: In HF patients without MI, patients with intra-LV asynchrony are those with a significantly higher risk of cardiac events, independent of the QRS width and LVEF. Accordingly, such patients should be more actively identified for early intensive treatment and survey.

Aged↗

Incidence, clinical implications and prognosis of atrial arrhythmias in Brugada syndrome.

AIMS: This single-centre prospective study was designed to determine the incidence, therapeutic implications and prognosis of atrial arrhythmias (AA) in patients with Brugada syndrome (BS). METHODS AND RESULTS: Fifty nine consecutive patients with BS and 31 age and gender-matched controls underwent an electrophysiological exploration and were followed-up during 34+/-13 months. The final AA incidence was 20% in BS patients vs 0% in controls (p < 0.01). Ventricular inducibility was significantly related to a history of AA (p = 0.02). The incidence of AA in patients with a spontaneous electrocardiogram of BS was 26% vs 10% in patients with a flecainide-induced electrocardiogram (p < 0.05). In patients with an indication of implantable cardioverter defibrillator (ICD), the incidence of AA reached 27% vs 13% in patients with BS but without ICD indication (p < 0.05). Inappropriate shocks due to AA episodes were observed in 14% of ICD patients vs 10.5% of appropriate shocks. Multivariate analysis identified the implantation of a single-chamber device as an independent predictive factor of inappropriate ICD discharges (p < 0.05). CONCLUSION: BS patients exhibit an abnormally high proportion of AA. Our data strongly suggest a more advanced disease process in BS patients with spontaneous AA. Careful programming of single-chamber ICD should be recommended to avoid inappropriate discharges.

Adult↗

Prospective randomised comparison of irrigated-tip and large-tip catheter ablation of cavotricuspid isthmus-dependent atrial flutter.

BACKGROUND: Radiofrequency (RF) ablation of cavotricuspid isthmus (CTI) dependent flutter can be performed using different types of ablation catheters. It has been proposed that irrigated and large-tip catheters are capable of creating larger lesions, resulting in greater efficacy. This prospective, randomised clinical study compared the efficacy of irrigated and large-tip catheters of different designs. METHODS: Eighty patients (69 men, 66+/-11 years) undergoing de novo RF ablation of CTI-dependent flutter were randomised to ablation using one of the following catheters: (i) externally-irrigated 20), (ii) internally-cooled (n=20), (iii) single sensor, 8-mm tip (n=20), or (iv) double sensor, 8-mm tip (n=20). The study endpoint was the demonstration of bidirectional CTI conduction block within 12 min of cumulative RF delivery. Crossover to the externally-irrigated catheter was permitted if this was not achieved. The ablation and procedural parameters, safety and efficacy were compared. RESULTS: The primary endpoint was achieved in 64 patients (80%), including all 20 patients randomised to the externally-irrigated catheter. Crossover was required in 16 patients: 9 initially using the internally-cooled catheter (45%), 3 using single-sensor, 8-mm-tip (15%), and 4 using double-sensor, 8-mm-tip (20%) catheters. The higher initial failure rate with the internally-cooled-tip catheter was significant compared to the externally-irrigated (p = 0.001) and single-sensor, 8-mm-tip (p = 0.04) catheters. The externally-irrigated catheter achieved the study endpoint more frequently with fewer RF applications of shorter duration compared to the internally-cooled-tip catheter and 8-mm-tip catheters, the difference being significant compared with internally cooled ablation. No major complications were observed. CONCLUSION: Among commonly used ablation catheters, the externally-irrigated catheter has a higher efficacy for rapid achievement of CTI block.

Aged↗

Biventricular pacing and left ventricular pacing in heart failure: similar hemodynamic improvement despite marked electromechanical differences.

INTRODUCTION: We conducted an acute echocardiographic study comparing hemodynamic and ventricular dyssynchrony parameters during left ventricular pacing (LVP) and biventricular pacing (BVP). We sought to clarify the mechanisms responsible for similar hemodynamic improvement despite differences in electrical activation. METHODS AND RESULTS: Thirty-three patients underwent echocardiography prior to implantation with a multisite pacing device (spontaneous rhythm [SR]) and 2 days after implantation (BVP and LVP). Interventricular dyssynchrony (pulsed-wave Doppler), extent of myocardium displaying delayed longitudinal contraction (%DLC; tissue tracking), and index of LV dyssynchrony (pulsed-wave tissue Doppler imaging) were assessed. Compared to SR, BVP and LVP caused similar significant improvement of cardiac output (LVP: 3.2 +/- 0.5, BVP: 3.1 +/- 0.7, SR: 2.3 +/- 0.6 L/min; P < 0.01) and mitral regurgitation (LVP: 25.1 +/- 10, BVP: 24.7 +/- 11, baseline: 37.9 +/- 14% jet area/left atria area; P < 0.01). LVP resulted in a smaller index of LV dyssynchrony than BVP (29 +/- 10 vs 34 +/- 14; P < 0.05). However, LVP exhibited a longer aortic preejection delay (220 +/- 34 vs 186 +/- 28 msec; P < 0.01), longer LV electromechanical delays (244.5 +/- 39 vs 209.5 +/- 47 msec; P < 0.05), greater interventricular dyssynchrony (56.6 +/- 18 vs 31.4 +/- 18; P < 0.01), and higher%DLC (40.1 +/- 08 vs 30.3 +/- 09; P < 0.05), leading to shorter LV filling time (387 +/- 54 vs 348 +/- 44 msec; P < 0.05) compared to BVP. CONCLUSION: Although LVP and BVP provide similar hemodynamic improvement, LVP results in more homogeneous but substantially delayed LV contraction, leading to shortened filling time and less reduction in postsystolic contraction. These data may influence the choice of individual optimal pacing configuration.

Aged↗

Blood pressure surge on rising.

OBJECTIVES: Since cardiovascular complications tend to occur more often in the morning, it is tempting to link this to the surge in blood pressure (BP) on rising. Our objective was to measure BP and heart rate (HR) on rising and compare values with those recorded immediately beforehand and seek variables related to marked changes in the two parameters in a cohort of initially untreated hypertensives. METHODS: The 24-h ambulatory BP measurement along with an accurate measurement of the BP on rising (either manually or automatically from the device coupled with a position sensor) was obtained in untreated hypertensives. Left ventricular mass was measured with echocardiography at baseline. Patients were then treated and followed by their general physician and news was obtained at regular intervals. RESULTS: A total of 507 patients with adequate recordings were included. Rising led to a mean increase of 14 mmHg in systolic blood pressure (SBP) and a 13 beats per minute (bpm) increase in HR. This elevation in BP on rising in the morning differed from the alteration in BP on normal changes in position. It was associated with left ventricular hypertrophy at baseline and an increased risk of future cardiovascular complications. CONCLUSIONS: Our study confirms the surge in BP on rising in the morning. This elevation in BP is accompanied by an acceleration in cardiac rhythm with no significant correlation between the two parameters. The increase in BP on rising was linked with the overall variability in BP, but was independent of the mean BP over 24 h. It was associated with an increased risk of cardiovascular complications independently of age and average 24-h SBP.

Adolescent↗