PubMed Health⌕ Search

Biomedical subjects

Jadranka Spahija

Publications and source records attributed to Jadranka Spahija.

4 recordsLinked to original sources

Diaphragmatic function in advanced Duchenne muscular dystrophy.

The aim of this study was to assess diaphragm electrical activation and diaphragm strength in patients with advanced Duchenne muscular dystrophy during resting conditions. Eight patients with advanced Duchenne muscular dystrophy (age of 25 +/- 2 years) were studied during tidal breathing, maximal inspiratory capacity, maximal sniff inhalations, and magnetic stimulation of the phrenic nerves. Six patients were prescribed home mechanical ventilation (five non-invasive and one tracheotomy). Transdiaphragmatic pressure and diaphragm electrical activation were measured using an esophageal catheter. During tidal breathing (tidal volume 198 +/- 83 ml, breathing frequency 25 +/- 7), inspiratory diaphragm electrical activation was clearly detectable in seven out of eight patients and was 12 +/- 7 times above the noise level, and represented 45 +/- 19% of the maximum diaphragm electrical activation. Mean inspiratory transdiaphragmatic pressure during tidal breathing was 1.5 +/- 1.2 cmH2O, and during maximal sniff was 7.6 +/- 3.6 cmH2O. Twitch transdiaphragmatic pressure deflections could not be detected. This study shows that despite near complete loss of diaphragm strength in advanced Duchenne muscular dystrophy, diaphragm electrical activation measured with an esophageal electrode array remains clearly detectable in all but one patient.

Action Potentials↗

Closed-loop control of respiratory drive using pressure-support ventilation: target drive ventilation.

By using diaphragm electrical activity (multiple-array esophageal electrode) as an index of respiratory drive, and allowing such activity above or below a preset target range to indicate an increased or reduced demand for ventilatory assistance (target drive ventilation), we evaluated whether the level of pressure-support ventilation can be automatically adjusted in response to exercise-induced changes in ventilatory demand. Eleven healthy individuals breathed through a circuit (18 cm H2O/L/second inspiratory resistance at 1 L/second flow; 0.5-1.0 L/second expiratory flow limitation) connected to a modified ventilator. Subjects breathed for 6-minute periods at rest and during 20 and 40 W of bicycle exercise, with and without target drive ventilation (the target was set to 60% of the increase in diaphragm electrical activity observed between rest and 20 W of unassisted exercise). With target drive ventilation during exercise, the level of pressure-support ventilation was automatically increased, reaching 13.3 +/- 4.0 and 20.3 +/- 2.8 cm H2O during 20- and 40-W exercise, respectively, whereas diaphragm electrical activity was reduced to a level within the target range. Both diaphragmatic pressure-time product and end-tidal CO2 were significantly reduced with target drive ventilation at the end of the 20- (p < 0.01) and 40-W (p < 0.001) exercise periods. Minute ventilation was not altered. These results demonstrate that target drive ventilation can automatically adjust pressure-support ventilation, maintaining a constant neural drive and compensating for changes in respiratory demand.

Adult↗

Effect of increased diaphragm activation on diaphragm power spectrum center frequency.

Increased transdiaphragmatic pressure, reduced muscle blood flow, and increased duty cycle have all been associated with a reduction in the center frequency (CFdi) of the diaphragm's electrical activity (EAdi). However, the specific influence of diaphragm activation on CFdi is unknown. We evaluated whether increased diaphragm activation would result in a greater decline in the CFdi when pressure-time product (PTPdi) was kept constant. Five healthy subjects performed periods of intermittent quasi-static diaphragmatic contractions with a fixed duty cycle. In separate runs, subjects targeted transdiaphragmatic pressures (Pdi) by performing end-inspiratory holds with the glottis open and expulsive maneuvers at end-expiratory lung volume (EELV). Diaphragm activation and pressures were measured with an electrode array and balloons mounted on an esophago-gastric catheter, respectively. The EAdi, which was 25+/-8%(S.D.) of maximum at EELV, increased to 61+/-8% (P<0.001) when an identical Pdi (averaging 31+/-13 cmH2O) was generated at a higher lung volume (77% of inspiratory capacity). The latter was associated with a 17% greater decline in CFdi (P=0.012). In order to reproduce at EELV, the decrease in CFdi observed at the increased lung volume, a two-fold increase in PTPdi was required. We conclude that CFdi responds specifically to increased diaphragm activation when pressure-time product remains constant.

Action Potentials↗

Effects of imposed pursed-lips breathing on respiratory mechanics and dyspnea at rest and during exercise in COPD.

STUDY OBJECTIVES: To investigate the effect of volitional pursed-lips breathing (PLB) on breathing pattern, respiratory mechanics, operational lung volumes, and dyspnea in patients with COPD. SUBJECTS: Eight COPD patients (6 male and 2 female) with a mean (+/-SD) age of 58 +/- 11 years and a mean FEV1 of 1.34 +/- 0.44 L (50 +/- 21% predicted). METHODS: Wearing a tight-fitting transparent facemask, patients breathed for 8 min each, with and without PLB at rest and during constant-work-rate bicycle exercise (60% of maximum). RESULTS: PLB promoted a slower and deeper breathing pattern both at rest and during exercise. Whereas patients had no dyspnea with or without PLB at rest, during exercise dyspnea was variably affected by PLB across patients. Changes in the individual dyspnea scores with PLB during exercise were significantly correlated with changes in the end-expiratory lung volume (EELV) values estimated from inspiratory capacity maneuvers (as a percentage of total lung capacity; r2 = 0.82, p = 0.002) and with changes in the mean inspiratory ratio of pleural pressure to the maximal static inspiratory pressure-generating capacity (PcapI) [r2 = 0.84; p = 0.001], measured using an esophageal balloon, where PcapI was determined over the range of inspiratory lung volumes and adjusted for flow. CONCLUSION: PLB can have a variable effect on dyspnea when performed volitionally during exercise by patients with COPD. The effect of PLB on dyspnea is related to the combined change that it promotes in the tidal volume and EELV and their impact on the available capacity of the respiratory muscles to meet the demands placed on them in terms of pressure generation.

Adult↗