PubMed Health⌕ Search

Biomedical subjects

Jaime Castillo

Publications and source records attributed to Jaime Castillo.

4 recordsLinked to original sources

Simultaneous detection of L-glutamate and nitric oxide from adherently growing cells at known distance using disk shaped dual electrodes.

An ex vivo system for simultaneous detection of nitric oxide (NO) and L-glutamate using integrated dual 250 microm platinum disk electrodes modified individually with suitable sensing chemistries has been developed. One of the sensors was coated with an electrocatalytic layer of Ni tetrasulfonate phthalocyanine tetrasodium salt (Ni-TSPc) covered by second layer of Nafion, which stabilises on the one hand the primary oxidation product NO(+) and prevents interferences from negatively charged compounds such as NO(2)(-). For glutamate determination, the second electrode was modified with a crosslinked redox hydrogel consisting of Os complex modified poly(vinylimidazol), glutamate oxidase and peroxidase. A manual x-y-z micromanipulator on top of an inverted optical microscope was used to position the dual electrode sensor at a defined distance of 5 microm from a cell population under visual control. C6 glioma cells were stimulated simultaneously with bradykinin or VEGF to release NO while KCl was used to invoke glutamate release. For evaluation of the glutamate sensors, in some experiments HN10 cells were used. To investigate the sensitivity and reliability of the system, several drugs were applied to the cells, e.g. Ca(2+)-channel inhibitors for testing Ca(2+)-dependence of the release of NO and glutamate, rotenone for inducing oxidative stress and glutamate antagonists for analysing glutamate release. With these drugs the NO and glutamate release was modulated in a similar way then expected from previously described systems or even in-vivo measurements. We therefore conclude that our system is suitable to analyse stress-induced mechanisms in cell lines.

Animals↗

Glutamate detection from nerve cells using a planar electrodes array integrated in a microtiter plate.

There is an increasing interest in new strategies for replacing animal tests in research. The use of cell cultures and integrated electrodes is seen as a promising alternative that could potentially solve this problem. In this work, we present a L-glutamate sensor based on a bienzyme redox hydrogel, capable of detecting the release of this excitatory neurotransmitter from adherently growing cells upon stimulation. The low working potential required for the operation of the sensor decreases the possibility of interference by easily oxidizable compounds always present in complex biological samples. A low detection limit of 0.5 microM L-glutamate, a response time of about 35 s, and a linear range of up to 60 microM are the main characteristics of the sensor. The system has been successfully employed to monitor the release of l-glutamate from HN10 and C6 cells upon stimulation with K(+)-ions. The developed integrated electrochemical platform will be used in future for drug screening and potentially for replacing animal models in neurological experiments.

Biological Assay↗

Simultaneous detection of the release of glutamate and nitric oxide from adherently growing cells using an array of glutamate and nitric oxide selective electrodes.

The simultaneous detection of nitric oxide and glutamate using an array of individually addressable electrodes, in which the individual electrodes in the array were suitably modified with a highly sensitive nitric oxide sensing chemistry or a glutamate oxidase/redox hydrogel-based glutamate biosensor is presented. In a sequence of modification steps one of the electrodes was covered first with a positively charged Ni porphyrin entrapped into a negatively charged electrodeposition paint followed by the manual modification of the second working electrode by a bienzyme sensor architecture based on crosslinked redox hydrogels with entrapped peroxidase and glutamate oxidase. Adherently growing C6-glioma cells were grown on membrane inserts and placed in close distance to the modified sensor surfaces. The current responses recorded at each electrode after stimulation of glutamate and NO release by means of K+ and bradykinin clearly demonstrate the ability of the individual electrode in the array to detect the analyte towards which its sensitivity and selectivity was targeted without interference from the neighbouring electrode or other analytes present in the test mixture.

Animals↗

Bienzyme biosensors for glucose, ethanol and putrescine built on oxidase and sweet potato peroxidase.

Amperometric biosensors for glucose, ethanol, and biogenic amines (putrescine) were constructed using oxidase/peroxidase bienzyme systems. The H(2)O(2) produced by the oxidase in reaction with its substrate is converted into a measurable signal via a novel peroxidase purified from sweet potato peels. All developed biosensors are based on redox hydrogels formed of oxidases (glucose oxidase, alcohol oxidase, or amine oxidase) and the newly purified sweet potato peroxidase (SPP) cross-linked to a redox polymer. The developed electrodes were characterized (sensitivity, stability, and performances in organic medium) and compared with similarly built ones using the 'classical' horseradish peroxidase (HRP). The SPP-based electrodes displayed higher sensitivity and better detection limit for putrescine than those using HRP and were also shown to retain their activity in organic phase much better than the HPR based ones. The importance of attractive or repulsive electrostatic interactions between the peroxidases and oxidases (determined by their isoelectric points) were found to play an important role in the sensitivity of the obtained sensors.

Alcohol Oxidoreductases↗