Evaluation of emphysema severity and progression in a rabbit model: comparison of hyperpolarized 3He and 129Xe diffusion MRI with lung morphometry.

The apparent diffusion coefficients (ADCs) of hyperpolarized (3)He and (129)Xe gases were measured in the lungs of rabbits with elastase-induced emphysema and correlated against the mean chord length from lung histology. In vivo measurements were performed at baseline and 2, 4, 6, and 8 wk after instillation of elastase (mild and moderate emphysema groups) or saline (control group). ADCs were determined from acquisitions that used two b values. To investigate the effect of b value on the results, b-value pairs of 0 and 1.6 s/cm(2) and 0 and 4.0 s/cm(2) were used for (3)He, and b-value pairs of 0 and 5.0 s/cm(2) and 0 and 10.0 s/cm(2) were used for (129)Xe. At 8 wk after instillation, the rabbits were euthanized, and the lungs were analyzed histologically and morphometrically. ADCs for the rabbits in the control group did not change significantly from baseline to week 8, whereas ADCs for the rabbits in the emphysema groups increased significantly (P < 0.05) for all gas and b-value combinations except (129)Xe with the b-value pair of 0 and 5.0 s/cm(2). The largest percent change in mean ADC from baseline to week 8 (15.3%) occurred with (3)He and the b-value pair of 0 and 1.6 s/cm(2) for rabbits in the moderate emphysema group. ADCs (all b values) were strongly correlated (r = 0.62-0.80, P < 0.001) with mean chord lengths from histology. These results further support the ability of diffusion-weighted MRI with hyperpolarized gases to detect regional and global structural changes of emphysema within the lung.

Animals↗

q-Space analysis of lung morphometry in vivo with hyperpolarized 3He spectroscopy.

PURPOSE: To examine the utility of a (3)He spectroscopic q-space technique for detecting changes in lung morphometry in vivo. MATERIALS AND METHODS: A diffusion-weighted spectroscopy sequence was used to collect global diffusion data from healthy adults (N = 11), healthy children (N = 5), and chronic obstructive pulmonary disease (COPD) patients (N = 2) using 40 cc of hyperpolarized (3)He gas within a two second breathhold. Displacement probability profiles (DPP) were obtained by Fourier transformation of diffusion data with respect to q. A bi-Gaussian model was used to decompose the DPPs into narrow and broad components, characterized by root-mean-square displacements X(rms1) and X(rms2), respectively. RESULTS: In healthy adults, the narrow component (X(rms,1)) of the DPP had a mean displacement of 188 +/- 10 microm, slightly less than the reported average size of the alveoli. The broad component (X(rms,2)) had a mean value of 474 +/- 44 microm, comparable to the diameter of the respiratory bronchioles in the acinus. In children, both X(rms1) (167 +/- 4 microm) and X(rms2) (382 +/- 22 microm) compared to healthy adults (P < 0.01). In COPD patients, the mean displacements were elevated (X(rms1): 265 +/- 71 microm; X(rms2): 530 +/- 109 microm) compared to healthy adults. Excellent correlation was found between rms displacements and age (age vs. X(rms,1): r = 0.78, P < 0.001; age vs. X(rms,2): r = 0.90, P < 0.001). CONCLUSION: The q-space parameters agreed remarkably well with published alveolar morphometry data. The results suggest that the technique may be sensitive to disease, as evident from the elevated mean displacements in COPD patients compared to healthy volunteers. Detailed lung microstructural information can be obtained using a very low volume of inhaled (3)He.

Adult↗

Exploring lung function with hyperpolarized (129)Xe nuclear magnetic resonance.

With the use of polarization-transfer pulse sequences and hyperpolarized (129)Xe NMR, gas exchange in the lung can be measured quantitatively. However, harnessing the inherently high sensitivity of this technique as a tool for exploring lung function requires a fundamental understanding of the xenon gas-exchange and diffusion processes in the lung, and how these may differ between healthy and pathological conditions. Toward this goal, we employed NMR spectroscopy and imaging techniques in animal models to investigate the dependence of the relative xenon gas exchange rate on the inflation level of the lung and the tissue density. The spectroscopic results indicate that gas exchange occurs on a time scale of milliseconds, with an average effective diffusion constant of about 3.3 x 10(-6)cm(2)/s in the lung parenchyma. Polarization-transfer imaging pulse sequences, which were optimized based on the spectroscopic results, detected regionally increased gas-exchange rates in the lung, indicative of increased tissue density secondary to gravitational compression. By exploiting the gas-exchange process in the lung to encode physiologic parameters, these methods may be extended to noninvasive regional assessments of lung-tissue density and the alveolar surface-to-volume ratio, and allow lung pathology to be detected at an earlier stage than is currently possible.

Algorithms↗

Left ventricular remodeling subsequent to reperfused myocardial infarction: evaluation of a rat model using cardiac magnetic resonance imaging.

PURPOSE: This study characterized the time course of ventricular remodeling subsequent to reperfused myocardial infarction (MI) in a rat model using cardiac magnetic resonance (MR) imaging. METHODS AND RESULTS: Short axis cine MR imaging was used to measure left ventricular ejection fraction (LVEF) and left ventricular volumes in Lewis rats at baseline, 1, 2, 4, 6, 8, and 10 weeks post-MI. Ventricular pressure and myocardial mass were evaluated at the 10 week time point. RESULTS: Measurements of LVEF showed a significant decrease in cardiac function immediately after MI with no significant changes over the remainder of the time course. Measurements of left ventricular end-systolic volume (LVESV) showed significant increases over thefirst 4 weeks after MI with no significant changes over the remainder of the time course. Statistical analysis of the MR measurements of LVESV yielded a repeatability standard error of 3.3%, an inter-observer standard error of 3.3%, and an intra-observer standard error of 1.6%. CONCLUSION: This study indicates that cine MRI can be used to longitudinally evaluate changes in ventricular structure and function in a rat model of left ventricular remodeling. In this animal model, preliminary results indicate that the majority of remodeling is completed by 4 weeks and no significant changes in LVEF are seen after the first week. The repeatability values indicate that cardiac MR could be used for evaluating new therapies for mitigating the effects of LV remodeling after reperfused MI.

Animals↗