Age-dependent methamphetamine-induced alterations in vesicular monoamine transporter-2 function: implications for neurotoxicity.

Tens of thousands of adolescents and young adults have used illicit methamphetamine. This is of concern since its high-dose administration causes persistent dopaminergic deficits in adult animal models. The effects in adolescents are less studied. In adult rodents, toxic effects of methamphetamine may result partly from aberrant cytosolic dopamine accumulation and subsequent reactive oxygen species formation. The vesicular monoamine transporter-2 (VMAT-2) sequesters cytoplasmic dopamine into synaptic vesicles for storage and perhaps protection against dopamine-associated oxidative consequences. Accordingly, aberrant VMAT-2 function may contribute to the methamphetamine-induced persistent dopaminergic deficits. Hence, this study examined effects of methamphetamine on VMAT-2 in adolescent (postnatal day 40) and young adult (postnatal day 90) rats. Results revealed that high-dose methamphetamine treatment caused greater acute (within 1 h) decreases in vesicular dopamine uptake in postnatal day 90 versus 40 rats, as determined in a nonmembrane-associated subcellular fraction. Greater basal levels of VMAT-2 at postnatal day 90 versus 40 in this purified fraction seemed to contribute to the larger effect. Basal tissue dopamine content was also greater in postnatal day 90 versus 40 rats. In addition, postnatal day 90 rats were more susceptible to methamphetamine-induced persistent dopaminergic deficits as assessed by measuring VMAT-2 activity and dopamine content 7 days after treatment, even if drug doses were adjusted for age-related pharmacokinetic differences. Together, these data demonstrate dynamic changes in VMAT-2 susceptibility to methamphetamine as a function of development. Implications with regard to methamphetamine-induced dopaminergic deficits, as well as dopamine-associated neurodegenerative disorders such as Parkinson's disease, are discussed.

Age Factors↗

An evaluation of rapid point-of-collection oral fluid drug-testing devices.

New technology is currently being marketed to rapidly test oral fluids for drugs of abuse at the point of collection (POC). There are no nationally accepted standards or cutoff concentrations for detecting drugs in oral fluids and for most analytes there are significant differences in cutoff concentrations across devices. Four devices were evaluated (OralLab), RapiScan, Drugwipe, and SalivaScreen) for their ability to meet manufacturers claims, and proposed federal standards for criminal justice and workplace programs. Human oral fluid fortified with known quantities of drug [drug(s) or metabolite(s)] was used to test these devices. Overall, the performance of these rapid POC oral fluid drug-testing devices was quite variable. Some devices performed well for the analysis of some drug classes but poorly for others. In general, most devices performed well for the detection of methamphetamine and opiates, but all performed poorly for the detection of cannabinoids. The ability to accurately and reliably detect cocaine and amphetamine was dependent on the individual device.

Equipment Design↗

An evaluation of selected oral fluid point-of-collection drug-testing devices.

Point-of-collection oral fluids drug-testing devices are being marketed for a variety of medico-legal purposes where they may complement existing technologies and be used to detect drugs following recent ingestion. To assess the utility of these devices for use in drugged-driving investigations, we performed a laboratory evaluation of four devices and those results were published previously. In the study reported here, two more devices, Oratect(R) (Branan) and Uplink(R) (OraSure), were evaluated for their ability to detect amphetamines, cocaine, opiates, and cannabinoids. An additional device, Drugwipe (Securtec), was evaluated for the detection of cocaine and cannabinoids. Each of the devices was assessed for their ability to meet the manufacturers' claimed cutoff concentrations and to meet cutoffs proposed for federal workplace programs. In general, the Branan and OraSure devices detected amphetamine, methamphetamine, opiates, and cannabinoid metabolite (THC-COOH) well in the concentration ranges approximating those proposed by the Substance Abuse and Mental Health Services Administration (SAMHSA), but all three devices performed poorly in detecting Delta9-tetrahydrocannabinol (THC) at the proposed SAMHSA cutoff. The ability to accurately and reliably detect cocaine was dependent on the individual device, and the Branan and Securetec devices were more effective than OraSure at detecting parent cocaine.

Equipment Design↗