Comminuted talar neck fractures: a mechanical comparison of fixation techniques.

OBJECTIVE: To compare the mechanical performance of 3 fixation techniques for comminuted talar neck fractures. DESIGN: In vitro biomechanical study. SETTING: Bioengineering research laboratory. PARTICIPANTS: Thirty previously frozen human cadaveric tali were osteotomized across the talar neck. A wedge of bone 2 cm long and extending 50% of the medial to lateral and superior to inferior dimension of the talus was removed to create an unstable, comminuted fracture. INTERVENTION: The specimens were randomized to one of 3 fixation groups. The first group was fixed with 3 anterior-to-posterior screws. The second group was fixed with 2 cannulated screws inserted from posterior to anterior. The third group was fixed with 1 screw from anterior to posterior and a medially applied blade plate. Specimens were embedded in acrylic cement and mounted on an Instron mechanical testing machine. Loading was applied in the dorsal-medial direction to failure. MAIN OUTCOME MEASURES: For each specimen, the load-displacement curve, yield point, and 3 mm displacement point were recorded in response to controlled dorsal-medial loading to failure. Stiffness was calculated as the linear portion of the slope of the load (kN) versus displacement (mm) curve. Statistical analysis of the data was conducted using analysis of variance. RESULTS: The mean yield point of each of the fixation techniques tested exceeded 1.4 kN. No statistically significant difference was found between the fixation methods, even when variations in age and sex were considered. CONCLUSIONS: The mean yield point of the fixation techniques tested exceeds the theoretical stress across the talar neck during active motion. Anterior plate fixation provided equivalent stability to posterior screw fixation.

Adult↗

The effect of coronoid fractures on elbow kinematics and stability.

BACKGROUND: Coronoid fractures often occur in the setting of more complex elbow trauma. Little is known about the influence of coronoid fracture size on elbow kinematics, particularly in the setting of concomitant ligament injuries. The purpose of this study was to determine the effect of coronoid fractures on elbow kinematics and stability in ligamentously intact and medial collateral ligament deficient elbows and to determine the effect of forearm position on elbow stability in the setting of coronoid fracture. METHODS: Eight cadaveric arms were tested during simulated active dependent elbow motion and gravity-loaded passive elbow motion. Kinematic data were collected from an electromagnetic tracking system. The protocol was performed in ligament origin repaired and medial collateral ligament deficient elbows with radial head arthroplasty. Testing was carried out with the coronoid intact, and with 10% (Type I), 50% (Type II), and 90% (Type III) removed. Varus-valgus angulation of the ulna relative to the humerus and maximum varus-valgus laxity were measured. FINDINGS: With repaired ligament origins and medial collateral ligament deficiency, there was increased varus angulation and increased maximum varus-valgus laxity following simulation of a Type II and Type III coronoid fracture. There was less kinematic change with the forearm in supination than in pronation. INTERPRETATION: Elbow kinematics are altered with increasing coronoid fracture size. Repair of Type II and Type III coronoid fractures as well as lateral ligament repair is recommended where possible. Forearm supination may be considered during rehabilitation following coronoid repair. Valgus elbow positioning should be avoided if the medial collateral ligament is not repaired.

Aged↗

Glenoid vault endosteal dimensions: an anthropometric study with special interest in implant design.

An understanding of the morphology of the glenoid is important from the viewpoint of implant design and selection. This study describes the endosteal dimensions and shape of the glenoid and correlates these results with age, gender, and the presence of osteoarthritis. This study used 72 scapulae. Data were obtained from computed tomography scans of both cadaveric and in vivo glenoids. The glenoid is relatively straight-sided in the coronal plane and more highly fluted in the transverse plane. The endosteal dimensions were larger for male specimens, but there was no difference in endosteal shape with respect to gender. These findings were not influenced by age or the presence of osteoarthritis. This study suggests that traditional glenoid component designs may not be optimal. To maximize fixation, a rectangular keel may be most effective in the coronal plane and a triangular keel may be most effective in the transverse plane.

Adult↗

Effect of simulated muscle activity on distal radioulnar joint loading in vitro.

This study investigated the relationship between simulated forearm muscle loads and the joint reaction force in the distal radioulnar joint using an in vitro model. Seven fresh frozen cadaveric specimens were mounted in an upper extremity joint simulator capable of applying pneumatic loads to various (muscle) tendons while restraining the forearm in the three positions of pronation, supination, and neutral rotation. Loads were applied to model four forearm muscles (biceps, pronator teres, pronator quadratus, and supinator) in 10 N increments ranging from 10 N to 80 N for the biceps and pronator teres and in 10 N increments from 10 N to 50 N for the pronator quadratus and the supinator. Distal ulnar arthroplasty was performed on each specimen with a custom instrumented ulnar head replacement implant that quantified loads (via strain gauge instrumentation). The relationship between increasing muscle load and joint load was found to be positive and quasilinear in most cases. The biceps had the greatest influence on the distal radioulnar joint reaction force with a joint force in the range of 8% to 33% of the applied muscle load. The pronator teres, supinator, and pronator quadratus were less influential with a joint reaction force ranging between 6% to 19%, 4% to 9% and 2% to 10% of the applied muscle load, respectively.

Aged↗

Design and implementation of an instrumented ulnar head prosthesis to measure loads in vitro.

The development of a novel instrumented implant for ulnar head replacement is presented in this study. This implant was instrumented with strain gauges to quantify bending moments about the anatomic axes of the distal ulna, and subsequently the distal radioulnar joint (DRUJ) reaction force magnitude. The implant was surgically inserted in seven cadaveric upper extremities, which were subsequently mounted in a custom joint simulator. Simulated active unresisted pronation and supination motion trials were conducted using computer-controlled pneumatic actuators to simulate forearm musculature. Passive (unloaded) trials were also conducted. The reaction force across the DRUJ ranged from 2 to 10 N in magnitude during this unresisted motion. Increased bending moment magnitudes were measured when the forearm was positioned in supination compared to pronation. The magnitude of joint bending moments showed a consistent pattern with forearm position, regardless of simulated active or passive rotation, or supination and pronation motion trials. This result illustrates that the primary influence on joint load is likely the position and contact with the radial articulation. This study of DRUJ loading should be useful for biomechanical modeling, implant design considerations and improved knowledge of articular mechanics.

Aged↗

Cyclic loading of rotator cuff repairs: an in vitro biomechanical comparison of bioabsorbable tacks with transosseous sutures.

PURPOSE: This study compares rotator cuff repair strength after cyclic loading of bioabsorbable tacks and traditional transosseous sutures, and correlates the results with bone density, age, and gender. The hypotheses were that tack repair strength would be inferior to transosseous sutures and that repair strength would be directly related to bone quality. TYPE OF STUDY: In vitro randomized biomechanical study. METHODS: Eight paired cadaveric shoulders with a standardized supraspinatus defect were randomized to tack or suture repair and subjected to step-wise cyclic loading. Repair migration was measured by quantifying the motion of markers affixed to tendon and bone using a digital camera. Failure mode, cycles, and load were measured for 50% and 100% loss of repair. Results were correlated with bone density, age, and gender. RESULTS: Tack repairs failed at the tack-tendon interface, whereas suture rupture was the mode of failure for the suture repairs. Mean values for 50% loss of repair were 206 +/- 88 cycles and 44 +/- 15 N for the sutures, and 1,193 +/- 252 cycles and 156 +/- 20 N for the tacks (P < .05). The corresponding values for 100% loss of repair were 2,458 +/- 379 cycles and 294 +/- 27 N for the sutures, and 2,292 +/- 333 cycles and 263 +/- 28 N for the tacks (P > .05). These results did not correlate with bone density, age, or gender. CONCLUSIONS: This study has shown that bioabsorbable tacks provide improved repair strength in comparison with traditional suture techniques. Repair strength did not correlate with bone quality, and this may be attributed to failure primarily through the repair construct or at the tack-tendon interface and not through bone. This report describes a new high-resolution optical method of measuring tendon repair strength that should be a useful model for future studies. CLINICAL RELEVANCE: This study demonstrates the biomechanical advantages of a sutureless tack device for rotator cuff repair compared with a traditional augmented suture repair technique.

Absorbable Implants↗

Mechanical properties of cancellous bone of the distal humerus.

BACKGROUND: The objectives of this study were to quantify the indentation strength and modulus of distal humeral cancellous bone, and to identify regional variations. The motivations were to assist in prosthesis development and to optimize screw placement. METHODS: Three consecutive 3mm transverse slices were sectioned from the distal ends of seven fresh-frozen cadaveric specimens. A 3 x 3mm grid was drawn on each slice, providing locations for indentation using a flat cylindrical indenter (diameter=1.6mm) attached to a materials testing machine. The mean indentation modulus and local yield strength were calculated for each site, and pooled into nine anatomically defined regions. FINDINGS: Indentation modulus was found to range from 2.9 to 1041.7 MPa with a mean of 309.8 (242.0)MPa. Local yield strength was found to range from 0.6 to 16.3 MPa, with a mean value of 4.4 (2.5)MPa. The most distal slice had higher modulus values (P<0.05), and the posterior lateral region had lower modulus values (P<0.05). There were no slice or regional differences in strength. INTERPRETATION: The influence of slice depth emphasizes the importance of minimizing the amount of bone removed during prosthetic replacement. Regional variations in indentation modulus suggest that the posterior lateral region should be avoided during fixation of implants or placement of screws. A comparison with proximal tibial cancellous bone properties suggests the distal humerus may carry loads approaching 45% of those at the knee, assuming that bone adapts to stress magnitudes.

Aged↗

Comparison of distal radioulnar joint reconstructions using an active joint motion simulator.

PURPOSE: Distal radioulnar joint (DRUJ) instability can result in pain and functional disability. Numerous DRUJ reconstructive options have been described with minimal biomechanical analysis. The purpose of this study was to evaluate the ability of 4 well-described DRUJ reconstructions to restore joint kinematics using a dynamic, motion-controlled simulator. METHODS: Eleven cadaveric upper extremities had computer-controlled simulated active forearm rotation. Joint kinematics were quantified by using an electromagnetic tracking system. We compared the passive and simulated active kinematics of the intact, unstable, and reconstructed DRUJ (capsular repair, 2 described radioulnar ligament reconstructions, and a radioulnar tethering procedure). RESULTS: All reconstructions improved significantly the kinematics of the unstable DRUJ. The capsule repair restored simulated active joint kinematics closest to the intact DRUJ. CONCLUSIONS: All 4 reconstructions improved DRUJ stability significantly. The capsule repair most closely matched intact DRUJ kinematics and the radioulnar ligament reconstructions were found to be superior to a radioulnar tethering procedure.

Adult↗

The effect of radial head fracture size on elbow kinematics and stability.

This study determined the effect of radial head fracture size and ligament injury on elbow kinematics. Eight cadaveric upper extremities were studied in an in vitro elbow simulator. Testing was performed with ligaments intact, with the medial collateral (MCL) or lateral collateral (LCL) ligament detached, and with both the MCL and LCL detached. Thirty degree wedges were sequentially removed from the anterolateral radial head up to 120 degrees . Valgus angulation and external rotation of the ulna relative to the humerus were determined for passive motion, active motion, and pivot shift testing with the arm in a vertical (dependent) orientation. Maximum varus-valgus laxity was calculated from measurements of varus and valgus angulation with the arm in horizontal gravity-loaded positions. No effect of increasing radial head fracture size was observed on valgus angulation during passive and active motion in the dependent position. In supination, external rotation increased with increasing fracture size during passive motion with LCL deficiency and both MCL and LCL deficiency. With intact ligaments, maximum varus-valgus laxity increased with increasing radial head fracture size. With ligament disruption, elbows were grossly unstable, and no effect of increasing radial head fracture size occurred. During pivot shift testing, performed with the ligaments intact, subtle instability was noted after resection of one-third of the radial head. In this in vitro biomechanical study, small subtle effects of radial head fracture size on elbow kinematics and stability were seen in both the ligament intact and ligament deficient elbows. These data suggest that fixation of displaced radial head fractures less than or equal to one-third of the articular diameter may have some biomechanical advantages; however, clinical correlation is required.

Aged↗

Internal fixation of radial neck fractures: an in vitro biomechanical analysis.

OBJECTIVE: To assess the fixation rigidities of a custom designed blade plate, a 2.7 mm T-plate and 3.0 mm cannulated screws. DESIGN: A cadaveric non-comminuted radial neck fracture model was employed to test the three fixation methods, using a multi-directional shear loading protocol. BACKGROUND: The management of displaced radial neck fractures in adults remains unsatisfactory due to failure of internal fixation with secondary loss of reduction, and non-unions. METHODS: The stiffness of the various fixation methods was measured in five directions of loading in the transverse plane. Failure testing was performed on the final testing condition for each specimen, in a posteroulnar to anteroradial direction. RESULTS: The direction of specimen loading did not have a significant effect on the stiffness of the various methods of fixation (P = 0.4). There was no significant difference in the fixation stiffness between the 3.0 mm screws or blade plate, however, both were superior to the T-plate (P < 0.05). CONCLUSIONS: Although the 2.7 mm T-plate has been reported in the literature as a viable method of fixation for radial neck fractures, it may not be optimal from the viewpoint of fixation stability. In the setting of a non-comminuted radial neck fracture, the use of cross-cannulated screws or blade plate fixation is preferred.Relevance This study supports the use of cross-cannulated screws or blade plate fixation for non-comminuted fractures of the radial neck.

Aged↗

Interfragmentary compression across a simulated scaphoid fracture--analysis of 3 screws.

PURPOSE: To measure the interfragmentary compression generated across a simulated fracture in cadaveric scaphoids by 3 different headless compression screws. METHODS: A transverse osteotomy was made through the waist of each scaphoid and a load cell to measure compression was interposed between the fragments, which were then fixed internally retrograde with either an Acutrak Standard (n = 10), Acutrak Mini (n = 12), or Bold (n = 10) screw. The surgeon was blinded to the measured compression, which was recorded during screw insertion and for the following 5 minutes. As a measure of scaphoid bone quality the modulus of elasticity of the trabecular bone of each specimen was then calculated from uniaxial compression tests. RESULTS: The mean interfragmentary compression generated by the Acutrak Standard screw was significantly greater and more consistent than the Bold screw or the Acutrak Mini screw. The compression achieved by the Acutrak Standard screw was also more consistent than that obtained by either the Bold or the Acutrak Mini screws as reflected by the lower standard deviation. The mean modulus of elasticity of the scaphoid trabecular bone was similar for each screw group. CONCLUSIONS: The interfragmentary compression generated by the Acutrak Standard screw was significantly greater and more consistent than that generated by either the Bold or Acutrak Mini screws. The compression generated by the Acutrak Standard and Mini screws was significantly better sustained over time than that generated by the Bold screw; however, these differences were small and may not be clinically important. The optimal compression required to promote scaphoid fracture union remains unknown and clinical trials are needed to further evaluate the outcome from using these devices.

Adult↗

Soft-tissue stabilizers of the distal radioulnar joint: an in vitro kinematic study.

PURPOSE: Distal radioulnar joint (DRUJ) stability is dependent on osseous anatomy, soft-tissue stabilizers, and muscle activity. The relative importance of DRUJ soft-tissue stabilizers remains controversial and has not been examined in the more physiologic setting of simulated muscle loading in the intact specimen. The purpose of this study was to examine the role of static stabilizers on the kinematics of the DRUJ during active simulated motion. METHODS: Twelve cadaveric upper extremities underwent computer-controlled, simulated, active forearm rotation. Joint kinematics were measured in the intact specimen and after sequential sectioning of soft-tissue stabilizers including the dorsal and palmar radioulnar ligaments (RULs) and the triangular fibrocartilage (TFC), dorsal and palmar capsule, ulnocarpal ligaments (UCL), extensor carpi ulnaris (ECU) subsheath, pronator quadratus (PQ), and the interosseous membrane (IOM). RESULTS: After sectioning of soft tissues significant changes in the DRUJ kinematics were observed. With a distal to proximal sectioning sequence significant alterations in kinematics were not identified until sectioning of the IOM; with a proximal to distal sectioning sequence intact DRUJ kinematics were maintained until the final soft-tissue (RULs and TFC) sectioning. CONCLUSIONS: Sectioning of all soft-tissue stabilizers produced significant DRUJ instability and abnormal joint kinematics. The RULs and TFC play a key role in DRUJ kinematics because they can help to maintain normal joint rotation in the absence of all other soft-tissue stabilizers. With the preservation of other soft-tissue stabilizers, however, the RULs and TFC are not essential for the maintenance of normal kinematics of the DRUJ.

Adult↗

Assessment of screw displacement axis accuracy and repeatability for joint kinematic description using an electromagnetic tracking device.

Screw displacement axes (SDAs) have been employed to describe joint kinematics in biomechanical studies. Previous reports have investigated the accuracy of SDAs combining various motion analysis techniques and smoothing procedures. To our knowledge, no study has assessed SDA accuracy describing the relative movement between adjacent bodies with an electromagnetic tracking system. This is important, since in relative motion, neither body is fixed and consequently sensitivity to potential measurement errors from both bodies may be significant. Therefore, this study assessed the accuracy of SDAs for describing relative motion between two moving bodies. We analyzed numerical simulated data, and physical experimental data recorded using a precision jig and electromagnetic tracking device. The numerical simulations demonstrated SDA position accuracy (p=0.04) was superior for single compared to relative body motion, whereas orientation accuracy (p=0.2) was similar. Experimental data showed data-filtering (Butterworth filter) improved SDA position and orientation accuracies for rotation magnitudes smaller or equal to 5.0 degrees, with no effect at larger rotation magnitudes (p<0.05). This suggests that in absence of a filter, SDAs should only be calculated at rotations of greater than 5.0 degrees. For rotation magnitudes of 0.5 degrees (5.0 degrees ) about the SDA, SDA position and orientation error measurements determined from filtered experimental data were 3.75+/-0.30 mm (3.31+/-0.21 mm), and 1.10+/-0.04 degrees (1.04+/-0.03 degrees ), respectively. Experimental accuracy values describing the translation along and rotation about the SDA, were 0.06+/-0.00 mm and 0.09+/-0.01 degrees, respectively. These small errors establish the capability of SDAs to detect small translations, and rotations. In conclusion, application of SDAs should be a useful tool for describing relative motion in joint kinematic studies.

Algorithms↗

Electromyographic activity and strength during maximum isometric pronation and supination efforts in healthy adults.

There exists a lack of quantitative data in the literature related to the torque produced during axial forearm rotation and the electromyographic (EMG) activity of the muscles involved. Therefore, the purpose of this study was to compare the relative EMG activity of four forearm muscles during resisted forearm rotation. A custom-built device capable of measuring torque in the absence of grip was employed. Fourteen healthy volunteers performed maximum isometric voluntary contractions in five positions of axial forearm rotation for both pronation and supination. EMG data were collected simultaneously from the supinator, biceps, pronator quadratus (deep and superficial heads), and pronator teres muscles using fine-wire bipolar electrodes. Data were analyzed to determine the contributions of each muscle to pronation and supination torque over five positions of forearm rotation. In the absence of grip no significant difference was found between supination and pronation torque in neutral position. Supination torque generation was greater in the pronated forearm positions, and pronation torque was greater in the supinated positions (p<0.05). A root-mean-square EMG analysis verified the major contributions of the pronator teres and both heads of the pronator quadratus muscle to pronation torque, and supinator and biceps to supination torque. The deep head of the pronator quadratus was active during both pronation and supination, lending support to the theory that it may act primarily as a dynamic distal radioulnar joint stabilizer. This information may be helpful in upper extremity modeling, surgical treatments, and rehabilitation strategies.

Adult↗

The effect of radial head excision and arthroplasty on elbow kinematics and stability.

BACKGROUND: Radial head fractures are common injuries. Comminuted radial head fractures often are treated with radial head excision with or without radial head arthroplasty. The purpose of the present study was to determine the effect of radial head excision and arthroplasty on the kinematics and stability of elbows with intact and disrupted ligaments. We hypothesized that elbow kinematics and stability would be (1) altered after radial head excision in elbows with intact and disrupted ligaments, (2) restored after radial head arthroplasty in elbows with intact ligaments, and (3) partially restored after radial head arthroplasty in elbows with disrupted ligaments. METHODS: Eight cadaveric upper extremities were studied in an in vitro elbow simulator that employed computer-controlled actuators to govern tendon-loading. Testing was performed in stable, medial collateral ligament-deficient, and lateral collateral ligament-deficient elbows with the radial head intact, with the radial head excised, and after radial head arthroplasty. Valgus angulation and rotational kinematics were determined during passive and simulated active motion with the arm dependent. Maximum varus-valgus laxity was measured with the arm in a gravity-loaded position. RESULTS: In specimens with intact ligaments, elbow kinematics were altered and varus-valgus laxity was increased after radial head excision and both were corrected after radial head arthroplasty. In specimens with disrupted ligaments, elbow kinematics were altered after radial head excision and were similar to those observed in specimens with a native radial head after radial head arthroplasty. Varus-valgus laxity was increased after ligament disruption and was further increased after radial head excision. Varus-valgus laxity was corrected after radial head arthroplasty and ligament repair; however, it was not corrected after radial head arthroplasty without ligament repair. CONCLUSIONS: Radial head excision causes altered elbow kinematics and increased laxity. The kinematics and laxity of stable elbows after radial head arthroplasty are similar to those of elbows with a native radial head. However, radial head arthroplasty alone may be insufficient for the treatment of complex fractures that are associated with damage to the collateral ligaments as arthroplasty alone does not restore stability to elbows with ligament injuries.

Aged↗

Quantifying translations in the radiohumeral joint: application of a floating axis analysis.

The purpose of this study was to apply the Floating Axis analysis technique to the elbow joint, and to verify its ability to quantify clinically relevant radiohumeral translation in vitro using an electromagnetic tracking device. Of particular interest was the ability to quantify changes in anterior-posterior radial head translation, which is associated with the clinical condition of posterolateral rotatory instability of the elbow. Following the method proposed by Grood and Suntay to determine motions in the knee, an elbow coordinate system with axes representing the flexion-extension axis of the humerus, the long axis of the radius, and their mutual perpendicular, was developed. The algorithm was tested using a mechanical articulator that modeled the Floating Axis approach. Translation errors using this articulator were 0.1+/-0.1mm. The algorithm was applied to kinematic data collected from 12 cadaveric elbows that underwent a pivot shift test prior and subsequent to transection of the lateral collateral ligament. Anterior-posterior radiohumeral translation increased significantly in these elbows following the ligament sectioning (p<0.0001), with the average magnitude of posterior translation increasing from 0.9 to 19.8mm at 90 degrees of flexion. This approach will provide valuable information related to alterations in elbow motion pathways, especially for studies aimed at quantifying changes in joint stability.

Aged↗