Use of benchmark dose-volume histograms for selection of the optimal technique between three-dimensional conformal radiation therapy and intensity-modulated radiation therapy in prostate cancer.

PURPOSE: The aim of this study was to develop and validate our own benchmark dose-volume histograms (DVHs) of bladder and rectum for both conventional three-dimensional conformal radiation therapy (3D-CRT) and intensity-modulated radiation therapy (IMRT), and to evaluate quantitatively the benefits of using IMRT vs. 3D-CRT in treating localized prostate cancer. METHODS AND MATERIALS: During the implementation of IMRT for prostate cancer, our policy was to plan each patient with both 3D-CRT and IMRT. This study included 31 patients with T1b to T2c localized prostate cancer, for whom we completed double-planning using both 3D-CRT and IMRT techniques. The target volumes included prostate, either with or without proximal seminal vesicles. Bladder and rectum DVH data were summarized to obtain an average DVH for each technique and then compared using two-tailed paired t test analysis. RESULTS: For 3D-CRT our bladder doses were as follows: mean 28.8 Gy, v60 16.4%, v70 10.9%; rectal doses were: mean 39.3 Gy, v60 21.8%, v70 13.6%. IMRT plans resulted in similar mean dose values: bladder 26.4 Gy, rectum 34.9 Gy, but lower values of v70 for the bladder (7.8%) and rectum (9.3%). These benchmark DVHs have resulted in a critical evaluation of our 3D-CRT techniques over time. CONCLUSION: Our institution has developed benchmark DVHs for bladder and rectum based on our clinical experience with 3D-CRT and IMRT. We use these standards as well as differences in individual cases to make decisions on whether patients may benefit from IMRT treatment rather than 3D-CRT.

Adult↗

Helical tomotherapy shielding calculation for an existing LINAC treatment room: sample calculation and cautions.

This paper reports a step-by-step shielding calculation recipe for a helical tomotherapy unit (TomoTherapy Inc., Madison, WI, USA), recently installed in an existing Varian 600C treatment room. Both primary and secondary radiations (leakage and scatter) are explicitly considered. A typical patient load is assumed. Use factor is calculated based on an analytical formula derived from the tomotherapy rotational beam delivery geometry. Leakage and scatter are included in the calculation based on corresponding measurement data as documented by TomoTherapy Inc. Our calculation result shows that, except for a small area by the therapists' console, most of the existing Varian 600C shielding is sufficient for the new tomotherapy unit. This work cautions other institutions facing the similar situation, where an HT unit is considered for an existing LINAC treatment room, more secondary shielding might be considered at some locations, due to the significantly increased secondary shielding requirement by HT.

Equipment Design↗

Errors in radiation oncology: a study in pathways and dosimetric impact.

As complexity for treating patients increases, so does the risk of error. Some publications have suggested that record and verify (R&V) systems may contribute in propagating errors. Direct data transfer has the potential to eliminate most, but not all, errors. And although the dosimetric consequences may be obvious in some cases, a detailed study does not exist. In this effort, we examined potential errors in terms of scenarios, pathways of occurrence, and dosimetry. Our goal was to prioritize error prevention according to likelihood of event and dosimetric impact. For conventional photon treatments, we investigated errors of incorrect source-to-surface distance (SSD), energy, omitted wedge (physical, dynamic, or universal) or compensating filter, incorrect wedge or compensating filter orientation, improper rotational rate for arc therapy, and geometrical misses due to incorrect gantry, collimator or table angle, reversed field settings, and setup errors. For electron beam therapy, errors investigated included incorrect energy, incorrect SSD, along with geometric misses. For special procedures we examined errors for total body irradiation (TBI, incorrect field size, dose rate, treatment distance) and LINAC radiosurgery (incorrect collimation setting, incorrect rotational parameters). Likelihood of error was determined and subsequently rated according to our history of detecting such errors. Dosimetric evaluation was conducted by using dosimetric data, treatment plans, or measurements. We found geometric misses to have the highest error probability. They most often occurred due to improper setup via coordinate shift errors or incorrect field shaping. The dosimetric impact is unique for each case and depends on the proportion of fields in error and volume mistreated. These errors were short-lived due to rapid detection via port films. The most significant dosimetric error was related to a reversed wedge direction. This may occur due to incorrect collimator angle or wedge orientation. For parallel-opposed 60 degrees wedge fields, this error could be as high as 80% to a point off-axis. Other examples of dosimetric impact included the following: SSD, approximately 2%/cm for photons or electrons; photon energy (6 MV vs. 18 MV), on average 16% depending on depth, electron energy, approximately 0.5 cm of depth coverage per MeV (mega-electron volt). Of these examples, incorrect distances were most likely but rapidly detected by in vivo dosimetry. Errors were categorized by occurrence rate, methods and timing of detection, longevity, and dosimetric impact. Solutions were devised according to these criteria. To date, no one has studied the dosimetric impact of global errors in radiation oncology. Although there is heightened awareness that with increased use of ancillary devices and automation, there must be a parallel increase in quality check systems and processes, errors do and will continue to occur. This study has helped us identify and prioritize potential errors in our clinic according to frequency and dosimetric impact. For example, to reduce the use of an incorrect wedge direction, our clinic employs off-axis in vivo dosimetry. To avoid a treatment distance setup error, we use both vertical table settings and optical distance indicator (ODI) values to properly set up fields. As R&V systems become more automated, more accurate and efficient data transfer will occur. This will require further analysis. Finally, we have begun examining potential intensity-modulated radiation therapy (IMRT) errors according to the same criteria.

Medical Errors↗

Toxicity after three-dimensional radiotherapy for prostate cancer on RTOG 9406 dose Level V.

PURPOSE: This is the first report of toxicity outcomes at dose Level V (78 Gy) on Radiation Therapy Oncology Group 9406 for Stages T1-T2 adenocarcinoma of the prostate. METHODS AND MATERIALS: A total of 225 patients were entered in this cooperative group, Phase I-II dose-escalation trial of three-dimensional conformal radiotherapy for localized carcinoma of the prostate treated to a dose of 78 Gy (Level V). Of these patients, 219 were analyzed for acute and 218 for late toxicity. A minimum of 2 Gy/fraction was prescribed to the planning target volume (PTV). Patients were stratified according to the risk of seminal vesicle invasion as determined by Gleason score and presenting prostate-specific antigen level. Group 1 patients had clinical Stages T1-T2 tumors with a seminal vesicle invasion risk of <15%. Group 2 patients had clinical Stages T1-T2 tumors with a seminal vesicle invasion risk of >/=15%. Patients in Group 1 were prescribed 78 Gy to a prostate PTV. Patients in Group 2 were prescribed 54 Gy to the prostate and seminal vesicles (PTV1) followed by a boost to the prostate only (PTV2) to 78 Gy. PTV margins of between 5 and 10 mm were required. The average time at risk for late Grade 3+ toxicity after therapy completion was 23.2 and 23.1 months for Groups 1 and 2, respectively. The frequency of Grade 3 or worse late effects was compared with a similar group of patients treated in Radiation Therapy Oncology Group (RTOG) studies 7506 and 7706, with length of follow-up adjustments made for the interval from therapy completion. A second comparison was made with 170 patients treated to dose Level III (79.2 Gy in 1.8 Gy/fraction) to see whether the fraction size affected toxicity. Unlike other dose levels, patients treated at dose Level III had treatment prescribed as a minimum to the gross tumor volume. This effectively lowered the volume of the rectum treated to the study dose. RESULTS: Acute toxicity at dose Level V (78 Gy) was remarkably low, with Grade 3 acute effects reported in only 4% of Group 1 and 2% of Group 2 patients. No Grade 4 or 5 acute toxicity was reported. There was no statistically significant difference in rates of acute toxicities in patients who were treated to 79.2 Gy at 1.8 Gy/fraction or 78 Gy at 2.0 Gy/fraction. Late toxicity continues to be low compared with RTOG historical controls. The observed rate of Grade 3 or worse late effects for Group 1 (6 cases) was significantly lower (p = 0.0042) than the 18.2 cases that would have been expected from the historical control. The observed rate for Group 2 (8 cases) was lower than the 15.5 cases expected, but this difference was not statistically significant (p = 0.06). A trend was noted that Group 2 patients treated on dose Level V had more late Grade 3 or worse toxicity than patients treated to a similar dose on Level III (7% vs. 1%, p = 0.06). A significantly (p < 0.0001) greater incidence of late Grade 2 or greater toxicity occurred in patients treated at dose Level V (30% and 33% for Groups 1 and 2, respectively) than at dose Level III (13% and 9% for Groups 1 and 2, respectively). The longer follow-up at dose Level III suggests these differences may increase with additional follow-up. CONCLUSION: Tolerance to three-dimensional conformal radiotherapy with 78 Gy in 2-Gy fractions remains better than expected compared with historical controls. The magnitude of any effect from fraction size and treatment volume requires additional follow-up.

Aged↗

Toxicity and outcome results of RTOG 9311: a phase I-II dose-escalation study using three-dimensional conformal radiotherapy in patients with inoperable non-small-cell lung carcinoma.

PURPOSE: To evaluate prospectively the acute and late morbidities from a multiinstitutional three-dimensional radiotherapy dose-escalation study for inoperable non-small-cell lung cancer. METHODS AND MATERIALS: A total of 179 patients were enrolled in a Phase I-II three-dimensional radiotherapy dose-escalation trial. Of the 179 patients, 177 were eligible. The use of concurrent chemotherapy was not allowed. Twenty-five patients received neoadjuvant chemotherapy. Patients were stratified at escalating radiation dose levels depending on the percentage of the total lung volume that received >20 Gy with the treatment plan (V(20)). Patients with a V(20) <25% (Group 1) received 70.9 Gy in 33 fractions, 77.4 Gy in 36 fractions, 83.8 Gy in 39 fractions, and 90.3 Gy in 42 fractions, successively. Patients with a V(20) of 25-36% (Group 2) received doses of 70.9 Gy and 77.4 Gy, successively. The treatment arm for patients with a V(20) > or =37% (Group 3) closed early secondary to poor accrual (2 patients) and the perception of excessive risk for the development of pneumonitis. Toxicities occurring or persisting beyond 90 days after the start of radiotherapy were scored as late toxicities. The estimated toxicity rates were calculated on the basis of the cumulative incidence method. RESULTS: The following acute Grade 3 or worse toxicities were observed for Group 1: 70.9 Gy (1 case of weight loss), 77.4 Gy (nausea and hematologic toxicity in 1 case each), 83.8 Gy (1 case of hematologic toxicity), and 90.3 Gy (3 cases of lung toxicity). The following acute Grade 3 or worse toxicities were observed for Group 2: none at 70.9 Gy and 2 cases of lung toxicity at 77.4 Gy. No patients developed acute Grade 3 or worse esophageal toxicity. The estimated rate of Grade 3 or worse late lung toxicity at 18 months was 7%, 16%, 0%, and 13% for Group 1 patients receiving 70.9, 77.4, 83.8, or 90.3 Gy, respectively. Group 2 patients had an estimated late lung toxicity rate of 15% at 18 months for both 70.9 and 77.4 Gy. The prognostic factors for late pneumonitis in multivariate analysis were the mean lung dose and V(20). The estimated rate of late Grade 3 or worse esophageal toxicity at 18 months was 8%, 0%, 4%, and 6%, for Group 1 patients receiving 70.9, 77.4, 83.8, 90.3 Gy, respectively, and 0% and 5%, respectively, for Group 2 patients receiving 70.9 and 77.4 Gy. The dyspnea index scoring at baseline and after therapy for functional impairment, magnitude of task, and magnitude of effort revealed no change in 63%, functional pulmonary loss in 23%, and pulmonary improvement in 14% of patients. The observed locoregional control and overall survival rates were each similar among the study arms within each dose level of Groups 1 and 2. Locoregional control was achieved in 50-78% of patients. Thirty-one patients developed regional nodal failure. The location of nodal failure in relationship to the RT volume was documented in 28 of these 31 patients. Twelve patients had isolated elective nodal failures. Fourteen patients had regional failure in irradiated nodal volumes. Two patients had both elective nodal and irradiated nodal failure. CONCLUSIONS: The radiation dose was safely escalated using three-dimensional conformal techniques to 83.8 Gy for patients with V(20) values of <25% (Group 1) and to 77.4 Gy for patients with V(20) values between 25% and 36% (Group 2), using fraction sizes of 2.15 Gy. The 90.3-Gy dose level was too toxic, resulting in dose-related deaths in 2 patients. Elective nodal failure occurred in <10% of patients.

Adenocarcinoma↗

Penile bulb dose and impotence after three-dimensional conformal radiotherapy for prostate cancer on RTOG 9406: findings from a prospective, multi-institutional, phase I/II dose-escalation study.

PURPOSE: To assess the relationship between the dose to the bulb of the penis and the risk of impotence in men treated on Radiation Therapy Oncology Group (RTOG) 9406. METHODS AND MATERIALS: Men enrolled on a Phase I/II dose-escalation study, RTOG 9406, who were reported to be potent at entry and evaluable (n = 158) were selected for inclusion. Follow-up evaluations were scheduled every 3, 4, and 6 months for the first, second, and the third through fifth years, then annually. At each follow-up visit an assessment of potency status was made. Penile structures were defined by a single observer blinded to the potency status, using Web-based, on-line software. The dosimetry for penile structures was calculated at the Quality Assurance Center at Washington University and provided to RTOG Statistical Headquarters to determine whether there was a relationship between dose and impotence. RESULTS: Patients whose median penile dose was > or = 52.5 Gy had a greater risk of impotence compared with those receiving <52.5 Gy (p = 0.039). In a multivariate analysis neither age, the dose to the prostate, nor the use of hormonal therapy correlated with the risk of impotence. CONCLUSIONS: Dose to the bulb of the penis seems to be associated with the risk of radiation-induced impotence.

Adult↗

Toxicity after three-dimensional radiotherapy for prostate cancer with RTOG 9406 dose level IV.

PURPOSE: This is the first report of the toxicity outcomes using dose level IV (74 Gy) on Radiation Therapy Oncology Group (RTOG) study 9406 for Stage T1-T2 prostate adenocarcinoma. METHODS AND MATERIALS: A total of 262 patients were entered in this cooperative group, Phase I-II, dose-escalation trial of three-dimensional conformal radiotherapy for localized prostate carcinoma treated to a dose of 74 Gy (Level IV); 256 patients were analyzable for toxicity. A minimal dose of 2 Gy/fraction was prescribed to the planning target volume (PTV). Patients were stratified according to the risk of seminal vesicle invasion on the basis of the Gleason score and presenting prostate-specific antigen level. Group 1 patients had clinical Stage T1-T2 tumors with a seminal vesicle invasion risk of <15%. Group 2 patients had clinical Stage T1-T2 tumors with a seminal vesicle invasion risk of >/=15%. Patients in Group 1 were prescribed 74 Gy to a prostate PTV. Patients in Group 2 were prescribed 54 Gy to the prostate and seminal vesicles (PTV1) followed by a boost to the prostate only (PTV2) to 74 Gy. PTV margins between 5 and 10 mm were required. Elective pelvic radiotherapy was not used. The frequency of late effects of Grade 3 or greater was compared with that for a similar group of patients treated in RTOG studies 7506 and 7706, with length of follow-up adjustments made for the interval from therapy completion. A second comparison was made with 206 patients treated to dose level II (73.8 Gy in 1.8-Gy fractions) to see whether the fraction size affected toxicity. RESULTS: The average months at risk for late Grade 3+ toxicity after therapy completion were 28.9 and 23.9 months for Group 1 and 2, respectively. Acute toxicity at dose level IV (74 Gy) was remarkably low, with Grade 3 acute effects reported in only 1% of Group 1 and 3% of Group 2 patients. No Grade 4 or 5 acute toxicities were reported. Late toxicity continued to be low compared with RTOG historical controls. One patient in Group 1 and 4 patients in Group 2 experienced Grade 3 bladder toxicity. Two patients in Group 2 experienced Grade 3 bowel toxicity. No Grade 4 or 5 late effects were reported. The rate of late Grade 2 toxicity (any type) was 23% and 16% in Group 1 and 2, respectively. The observed rate of Grade 3 or greater late effects for Group 1 (1 case) was significantly lower (p <0.0001) than the 18.5 cases that would have been expected from the historical control data. The observed rate for Group 2 (6 cases) was also significantly lower (p = 0.0009) than the 21.3 cases expected. No statistically significant difference was noted in the rate of acute or late toxicity in patients who were treated to 73.8 Gy at 1.8 Gy/fraction or 74 Gy at 2.0 Gy/fraction. Patients treated with the larger 2.0-Gy fractions tended to have more Grade 3 or greater toxicity than patients treated with 1.8-Gy fractions (2% vs. 1%, p = 0.09). The results after the longer follow-up with dose level II suggest these differences may increase with additional follow-up. CONCLUSION: Tolerance to three-dimensional conformal radiotherapy with 74 Gy in 2-Gy fractions remains better than expected compared with historical controls. The magnitude of any effect from fraction size requires additional follow-up.

Adenocarcinoma↗

Current ICRU definitions of volumes: limitations and future directions.

Volume definitions used in radiation treatment planning of 3-dimensional conformal radiation therapy (3DCRT) and intensity modulated radiation therapy (IMRT) play and important role in advancing these treatment modalities. IMRT is now recognized to be more sensitive to geometric uncertainties than 3DCRT and conventional radiation therapy because of its characteristic sharper dose gradients around target volumes and organs at risk. This article reviews the current state of the art in specifying volumes for 3DCRT and IMRT and discusses some of the limitations and potential pitfalls with the current International Commission on Radiation Units and Measurements (ICRU) Reports 50 and 62 recommendations, particularly in regard to issues of organ motion when irradiated by a time-dependent irradiation modality such as dynamic multileaf collimation IMRT or other methods that have a time component in beam delivery.

Dose Fractionation, Radiation↗

Elective nodal failures are uncommon in medically inoperable patients with Stage I non-small-cell lung carcinoma treated with limited radiotherapy fields.

PURPOSE: To review the outcome for 56 Stage I non-small-cell lung cancer treated definitively with three-dimensional conformal radiotherapy (3D-CRT) and to investigate the value of elective nodal irradiation in this patient population. METHODS AND MATERIALS: Between 1992 and 2001, 56 patients were treated with 3D-CRT for inoperable Stage I histologically confirmed non-small-cell lung cancer; 31 with T1N0 and 25 with T2N0 disease. All patients were treated with 3D-CRT to a median isocenter dose of 70 Gy (range 59.94-83.85) given in daily doses of 1.8 or 2 Gy. Prognostic factors were analyzed with respect to their impact on overall survival. Twenty-two patients received radiotherapy (RT) directed to elective regional lymphatics to doses of 45-50 Gy. The remaining 33 patients were treated to limited fields confined to the primary lung cancer with a margin. The patterns of failure were reviewed. RESULTS: The median follow-up was 20 months (range 6 months to 6 years). The actuarial local control rate was 88%, 69%, and 63%, at 1, 2, and 3 years, respectively. The actuarial cause-specific survival rate was 82%, 67%, and 51% at 1, 2, and 3 years, respectively. The actuarial overall survival rate was 73%, 51%, and 34% at 1, 2, and 3 years, respectively. The actuarial metastasis-free survival rate was 90%, 85%, and 81% at 1, 2, and 3 years, respectively. The RT dose was the only factor predictive of overall survival in our analysis. No statistically significant difference was noted in cause-specific or overall survival according to whether patients received elective nodal irradiation. Two of 33 patients treated with limited fields had regional nodal failure. CONCLUSION: Many patients with medically inoperable Stage I lung cancer die of intercurrent causes. The omission of the elective nodal regions from the RT portals did not compromise either the cause-specific or overall survival rate. Elective nodal failures were uncommon in the group treated with limited RT fields. A radiation dose 70 Gy was predictive of better survival in our population. We await the results of prospective trials evaluating high-dose RT in patients treated with RT alone for Stage I lung cancer.

Aged↗

Preliminary evaluation of low-grade toxicity with conformal radiation therapy for prostate cancer on RTOG 9406 dose levels I and II.

PURPOSE: To evaluate the rates of low-grade late effects in patients treated for prostate cancer on Radiation Therapy Oncology Group (RTOG) 9406. MATERIALS AND METHODS: Between August 1994 and September 1999, 424 patients were entered on this dose escalation trial of three-dimensional conformal radiation therapy (3D-CRT) for localized adenocarcinoma of the prostate at doses of 68.4 Gy (level I) and 73.8 Gy (level II). We have previously reported Grade 3 or greater late toxicity of patients treated on the first two dose levels of this trial. This analysis examines the distribution of all late toxicities in these patients. All radiation prescriptions were a minimum dose to a planning target volume (PTV). Patients were stratified according to clinical stage and risk of seminal vesicle invasion (SVI) based upon Gleason score and presenting prostate-specific antigen. Group 1 includes patients with T1,2 disease with SVI risk < 15%, and Group 2 includes patients with T1,2 disease with SVI risk > 15%. Group 3 patients had T3 disease. Average months at risk after completion of therapy ranged from 21.4 to 40.1 months for patients treated at dose level I and 10.0 to 34.2 months for patients at dose level II. The frequency of all grades of late effects was compared with a similar group of patients treated in RTOG studies 7506 and 7706 with adjustments made for the interval from completion of therapy. The RTOG toxicity scoring scales for late effects were used for grading. RESULTS: The rate of Grade 3 or greater late toxicity continues to be low compared with RTOG historical controls. No Grade 4 or 5 late sequelae were reported in any of the 393 evaluable patients during the period of observation. The frequency of patients free of any complications was lower in RTOG 9406 than in historical controls. In the 73 Group 1 patients treated on dose level 1, there were 24 patients without sequelae compared with an expected rate of 39.7 (p = 0.013), and in 80 Group 3 patients at dose level II there were 24 patients without sequelae when 56.2 were expected (p < 0.0001). Other groups treated at these dose levels demonstrated a nonsignificant reduction in the rate of patients free of any side effects. These data suggest that the reduction in high-grade morbidity may be related to a shift of complications to lower grades. CONCLUSIONS: Morbidity of 3D-CRT in the treatment of prostate cancer is low. It is important to continue to closely examine late effects in patients treated in RTOG 9406. The primary objective of dose escalation without an increase rate of >/= Grade 3 sequelae has been achieved. However, the reduction in Grade 3 complications may have resulted in a higher incidence of Grade 1 or 2 late effects. Because Grade 2 late effects may have a significant impact on a patient's quality of life, it is important to reduce these complications as much as possible. Clinical trials should use quality-of-life measures to determine that trade-offs between severity and rates of toxicity are acceptable to patients.

Adenocarcinoma↗

Interim report of toxicity from 3D conformal radiation therapy (3D-CRT) for prostate cancer on 3DOG/RTOG 9406, level III (79.2 Gy).

PURPOSE: A prospective Phase I dose escalation study was conducted to determine the maximally tolerated radiation dose in men treated with three-dimensional conformal radiotherapy (3D-CRT) for localized prostate cancer. This is a preliminary report of toxicity at Level III (79.2 Gy) on 3D Oncology Group/Radiation Therapy Oncology Group (RTOG) 9406. METHODS AND MATERIALS: Between November 26, 1996 and October 1, 1998, 173 patients with clinically organ-confined prostate cancer (T1 and T2) were accrued to a Level III dose of 79.2 Gy. One hundred sixty-nine patients were available for analysis of toxicity. Patients were registered to two groups according to the risk of seminal vesicle invasion (SVI) on the basis of presenting PSA and Gleason score. Group 1 patients had a calculated risk of SVI <15%, and Group 2 patients had a risk of SVI > or = 15%. For Group 1 patients, the planning target volume (PTV) margins were 5-10 mm around the prostate only. For Group 2 patients, the same margins were applied to the prostate and seminal vesicles (PTV(1)) for the initial 55.8 Gy; then treatment volume was reduced to the prostate only (PTV(2)). To reduce the rectal dose on dose Level III, the minimum PTV dose was limited to 73.8 Gy, whereas the minimum gross target volume dose was 79.2 Gy, both in 44 fractions. The incidence of > or = 3 Grade late effects was compared to that in a similar group of patients treated on RTOG 7506 and 7706 studies. RESULTS: Acute tolerance to 79.2 Gy was excellent with no patients experiencing > or = Grade 3 acute toxicity. The acute toxicity rate was comparable to that reported for previous lower dose levels. With the median follow-up of 3.3 years (range: 0.4-4.4 years), a total of 4 patients (2.4%) experienced Grade 3 late toxicity, three cases of which were related to the bladder, and one related to the rectum. There were no Grade 4 or 5 late complications noted during the period of observation. These results are also comparable to those reported at dose Levels I and II. The expected incidence of > or = 3 Grade 3 late toxicity was calculated using historical data from two previous RTOG prostate cancer trials, 7506 and 7706. The calculated risk accounted for the difference in follow-up duration between patients in this study and the historical experience. The observed rate of > or = Grade 3 late effects for Group 1 (two cases) is significantly lower (p = 0.0002) than the 17.6 cases that would have been expected from the historical control. The observed rate for Group 2 (two cases) was also significantly lower (p = 0.0037) than the 12.1 cases expected. CONCLUSION: Based on excellent tolerance of 3D-CRT for stages T1 and T2 prostate cancer, further biological dose escalation has been pursued to Levels IV and V, 74 Gy and 78 Gy, respectively, at 2 Gy per day, in an attempt to reduce the total treatment duration. This trial has closed. A Phase III comparative RTOG trial is being developed to determine whether high-dose 3D-CRT improves efficacy.

Adult↗

Toward automated quality assurance for intensity- modulated radiation therapy.

PURPOSE: To investigate whether high-quality, relatively inexpensive, document and transparency scanners used as densitometers are sufficiently quantitative for routine quality assurance (QA). METHODS AND MATERIALS: The scanner we investigated used a linear amplifier, digitizing gray-scale images to 12-bit resolution with a user-selected spatial resolution of 0.170 mm(2) pixels. To reduce Newton's rings artifacts, the standard glass platen was replaced by glass with an antireflective coating. Conversion of reading to transmission was conducted by permanently placing a calibrated photographic step tablet on the scanner platen. After conversion to light transmission, a zero-phase two-dimensional Wiener filter was used to reduce pixel-to-pixel signal variation. Light-scatter artifacts were removed by deconvolution of a measured light-spread kernel. The light-spread kernel artifacts were significant along the scanner's detector axis, but were insignificant along the scanning axis. RESULTS: Pixel-to-pixel noise was better than 2% for optical densities, ranging from 0.4 to 2.0 and 0 to 2.7 for the unfiltered and filtered images, respectively. The document scanning system response was compared against a confocal scanning laser densitometer. A series of IMRT dose distribution and dose calibration film sets were scanned using the two scanners, and the measured dose was compared. The maximum mean and standard deviation of the measured dose difference between the document scanner and confocal scanner was 1.48% and 1.06%, respectively. CONCLUSION: While the document scanners are not as flexible as dedicated film densitometers, these results indicate that, using the intensity and scatter corrections, the system provides accurate and precise measurements up to an optical density of 2.0, sufficient for routine IMRT film QA. For some film types, this requires the reduction in monitor units to limit the dose delivered to the film. The user must be cautious that the delivered IMRT dose is scaled appropriately. This inexpensive and accurate system is being integrated into an automated QA program.

Artifacts↗

Applicator-guided intensity-modulated radiation therapy.

PURPOSE: We are introducing a novel method for delivering highly conformal dose distributions to cervical cancer tumors using external beam intensity-modulated radiation therapy. The method, termed applicator-guided intensity-modulated radiation therapy (AGIMRT), will use an applicator substitute placed in the vagina and uterus to provide spatial registration and immobilization of the gynecologic organs. The main reason for the applicator substitute will be to localize the fornices, cervix, and uterus with the expectation that the other nearby organs will also be reproducibly positioned with respect to the applicator substitute. Intensity-modulated radiation therapy (IMRT) dose distributions will be used as a substitute for high-dose-rate intracavitary brachytherapy procedures. The flexibility of IMRT will enable customized dose distributions that have the potential to reduce complications and improve local control, especially for locally advanced disease. METHODS AND MATERIALS: To test the advantages of IMRT over intracavitary brachytherapy, volumetric scans of three cervical cancer patients were obtained with implanted CT-compatible applicators. IMRT dose distribution simulations using tomotherapy, were compared against intracavitary brachytherapy using cesium tubes to investigate the dosimetric differences of the two modalities. Because these tumor volumes do not image well on CT, the target volumes were defined as the isodose surface containing the traditional point A, defined as 2 cm superior to the vaginal fornices and 2 cm lateral to the intrauterine canal. One patient had a uterus that wrapped superior and anterior to the bladder. For this case, the cervix and uterus were selected as the target volume. To determine the potential for using an applicator substitute to localize internal organs, the posterior bladder and anterior rectal surfaces were localized relative to the colpostats. Comparisons of the colpostat-localized surfaces were conducted for two scan studies for 3 patients. RESULTS: The IMRT distributions covered the point-A isodose surfaces while reducing doses to the bladder and rectum. Brachytherapy showed extensive underdose regions in the target volume for the wrapped-around target. Spatial positioning was better than 0.7 and 1.3 cm in the rectum and bladder, respectively, indicating the potential that an applicator substitute may be able to localize these structures. CONCLUSIONS: AGIMRT has the potential for improving critical structure avoidance while maintaining highly reproducible and accurate internal organ registration found with brachytherapy.

Female↗

Performance evaluation of an 85-cm-bore X-ray computed tomography scanner designed for radiation oncology and comparison with current diagnostic CT scanners.

INTRODUCTION: The demand for computed tomography (CT) virtual simulation is constantly increasing with the wider adoption of three-dimensional conformal and intensity-modulated radiation therapy. Virtual simulation CT studies are typically acquired on conventional diagnostic scanners equipped with an external patient positioning laser system and specialized planning and visualization software. Virtual simulation technology has matured to a point where conventional simulators may be replaced with CT scanners. However, diagnostic CT scanner gantry bores (typically 65-70 cm) can present an obstacle to the CT simulation process by limiting patient positions, compared to those that can be attained in a conventional simulator. For example, breast cancer patients cannot always be scanned in the treatment position without compromising reproducibility and appropriateness of setup. Extremely large patients or patients requiring special immobilization or large setup devices are often unable to enter the limited-bore gantry. A dedicated 85-cm-bore radiation oncology CT scanner has the potential to eliminate these problems. The scanner should provide diagnostic-quality images at diagnostic-comparable dose levels. The purpose of this study was to independently evaluate the performance of a novel 85-cm-bore CT X-ray scanner designed specifically for radiation oncology and compare it against diagnostic-type, 70-cm-bore scanners that may be used in the same setting. MATERIALS AND METHODS: We performed image quality and dosimetric measurements on an 85-cm-bore CT scanner (AcQSim CT, Marconi Medical Systems, Inc., Cleveland, OH) and a 70-cm-bore, diagnostic-type scanner (UltraZ CT, Marconi Medical Systems, Inc.). Image quality measurements were performed using a manufacturer-supplied phantom (Performance Phantom, Marconi Medical Systems, Inc.), following the manufacturer's suggested testing procedures, and an independent image quality phantom (CATPHAN 500, The Phantom Laboratory, New York, NY). The standard image quality parameters evaluated for the purpose of comparison were as follows: slice thickness accuracy, high-contrast resolution (limiting spatial resolution), low-contrast resolution, uniformity and noise, and CT number accuracy and linearity. Standard head and body protocols were employed throughout most of our measurements and were kept equal between the two scanners. The computed tomography dose index was measured for standard head and body imaging protocols using accepted methods and procedures. For comparison purposes, data for a diagnostic-type, 70-cm-bore scanner (GE HighSpeed CT/i) were extracted from the literature. The results obtained for the 85-cm-bore scanner are compared with the following: (1) manufacturer-provided autoperformance phantom test results (validating its use for routine quality assurance), (2) a similar set of measurements performed on a conventional 70-cm-bore, diagnostic-type CT scanner (UltraZ CT, Marconi Medical Systems, Inc.), and (3) current available data on other diagnostic-type CT scanners (GE HighSpeed CT/i). RESULTS: Head and body doses seem on average to be slightly (1-2 cGy) higher for the 85-cm-bore unit than for conventional 70-cm units. Measured slice thickness was within acceptable criteria, +/-0.5 mm. There does not seem to be any significant difference in high-contrast resolution. Both units render a limiting value of approximately 7-8 lp/cm for slice thickness 8-10 mm. Both units exhibit comparable CT number uniformity, accuracy, and linearity. Noise levels seem to be slightly increased (by approximately 0.05-0.2%) for the large-bore geometry. Low-contrast resolution for both units was comparable (4.5-5.5 mm @ 0.35%). All image quality parameters are well within diagnostic acceptable levels. CONCLUSION: The overall imaging performance and mechanical integrity of the 85-cm-bore scanner are comparable to those of conventional diagnostic scanners that may be employed in a radiation oncology setting.

Computer Simulation↗

Gross tumor volume, critical prognostic factor in patients treated with three-dimensional conformal radiation therapy for non-small-cell lung carcinoma.

PURPOSE: Three-dimensional conformal radiation therapy (3D-CRT) has recently become widely available with applications for patients with non-small-cell lung cancer (NSCLC). These techniques represent a significant advance in the delivery of radiotherapy, including improved ability to delineate target contours, choose beam angles, and determine dose distributions more accurately than were previously available. The purpose of this study is to identify prognostic factors in a population of NSCLC patients treated with definitive 3D-CRT. METHODS AND MATERIALS: Between March 1991 and December 1998, 207 patients with inoperable NSCLC were treated with definitive 3D-CRT. Tumor targets were contoured in multiple sections from a treatment planning computed tomography (CT) scan. Three-dimensional treatment volumes and normal structures were reconstructed. Doses to the International Commission on Radiation Units and Measurements (ICRU) reference point ranged from 60 to 83.85 Gy with a median dose of 70 Gy. The median dose inhomogeneity was +/- 5% across planning target volume. Outcome was analyzed by prognostic factors for NSCLC including pretreatment patient and tumor-related factors (age, gender, race, histology, clinical stage, tumor [T] stage, and node [N] stage), parameters from our 3D-CRT system (gross tumor volume [GTV] in cm3), irradiation dose prescribed to isocenter, volume of normal lung exceeding 20 Gy (V20), and treatment with or without chemotherapy. The median follow-up time was 24 months (range, 7.5 months to 7.5 years). RESULTS: One and two-year overall survival rates for the entire group were 59% and 41%, respectively. Overall survival, cause-specific survival, and local tumor control were most highly correlated with the GTV in cm3. On multivariate analysis the independent variable most predictive of survival was the GTV. Traditional staging such as T, N, and overall clinical staging were not independent prognostic factors. Patients receiving ICRU reference doses > or =70 Gy had better local control and cause-specific survivals than those treated with lower doses (p = 0.05). Increased irradiation dose did not improve overall survival. CONCLUSIONS: GTV as determined by CT and 3D-CRT planning is highly prognostic for overall and cause-specific survival and local tumor control and may be important in stratification of patients in prospective therapy trials. T, N, and overall stage were not independent prognostic factors in this population of patients treated nonsurgically. The value of dose escalation beyond 70 Gy should be tested prospectively by clinical trial.

Adult↗

Trade-off to low-grade toxicity with conformal radiation therapy for prostate cancer on Radiation Therapy Oncology Group 9406.

The aim of this study was to evaluate and compare the rates of grade 2 or worse late effects in patients treated for prostate cancer on Radiation Therapy Oncology Group (RTOG) 9406. The authors previously have reported the results of patients treated on the first 2 dose levels of this study with respect to grade 3 or greater late toxicity. This analysis examines the incidence of grade 2 toxicity in this study. From August 1994 to September 1999, 424 patients were entered on this dose escalation trial of 3-dimensional conformal radiation therapy (3D CRT) for localized adenocarcinoma of the prostate at doses of 68.4 Gy (level I) and 73.8 Gy (level II). All radiation prescriptions were a minimum dose to a planning target volume. Patients were stratified according to clinical stage and risk of seminal vesicle invasion based on Gleason score and presenting prostate-specific antigen. Average time at risk after completion of therapy ranged from 33.1 to 40.1 months for patients treated at dose level I and 15.6 to 34.2 months for patients at dose level II. The frequency of late effects > or = grade 2 was compared with a similar group of patients treated on RTOG studies 7506 and 7706 with adjustments made for the interval from completion of therapy. The RTOG toxicity scoring scales for late effects were used. The rate of grade 3 or greater late toxicity continues to be low compared with RTOG historical controls. No grade 4 or 5 late complications were reported in any of the 406 evaluable patients during the period of observation. Interestingly, the incidence of grade 2 late toxicity was increased relative to historical controls in all groups and dose levels. In group 1, level I and group 3, level II, the increase in grade 2 complications was statistically significant; 16 complications were observed in group 1, level I when 9.2 were expected (P =.026) and 22 were observed in group 3, level II when 7.6 were expected (P <.0001). When examining all late effects > or = grade 2, there were no significant differences in the rate of late effects in both groups and both dose levels with the exception of group 1, level II. This, in combination with the statistically significant decrease in late effects > or = grade 3, suggests that in most circumstances there has been a shift of grade 3 complications to grade 2. In group 1, dose level II there was a statistically significant reduction in > or = grade 2 late effects, suggesting there was no shift from grade 3 to grade 2 in these patients. In this circumstance there may have been a global reduction in all complications or a shift to late effects less severe than grade 2. In group 2, dose level II there is a trend (P =.085) toward this same result. It is important to continue to examine late effects closely in patients treated on RTOG 9406. The primary objective of dose escalation without an increase rate of > or = grade 3 complications has been achieved. However, the reduction in grade 3 complications may have resulted in a higher incidence of grade 2 late effects. Because grade 2 late effects may have a significant impact on a patient's quality of life, it is important to reduce these complications as much as possible. Improved conformal treatment delivery with intensity-modulated radiation therapy or the use of radioprotective agents could be considered. Clinical trials should use quality-of-life measures to determine that trade-offs between severity and rates of toxicity are acceptable to patients.

Adenocarcinoma↗

Dose-volume specification: new challenges with intensity-modulated radiation therapy.

It has long been recognized that the specification of volumes and doses is an important issue for radiation oncology. Although in any individual center, policies and procedures of treatment delivery may be well understood by staff, reporting of treatment techniques in the archival literature in an unambiguous manner has been found to be less than desirable in many instances. For clinical studies utilizing three-dimensional conformal radiation therapy (3D-CRT), and even more so, intensity-modulated radiation therapy (IMRT), the situation has become even more complex. 3D-CRT and IMRT are now recognized to be more sensitive to geometric uncertainties than conventional radiation therapy because of their ability to create sharper dose gradients around target volumes and organs at risk (OARs). This article reviews the current status of specifying target volumes and doses for 3D-CRT and IMRT, and discusses some of the pertinent issues regarding the use of recommendations in Reports 50 and 62 of the International Commission on Radiation Units and Measurements (ICRU) in this task. It is imperative that physician and physicist fully appreciate the need to account for clinical and spatial uncertainties in the planning and delivery of cancer patients' treatment, paying even more attention to these issues for those cases in which 3D-CRT and/or IMRT is used. A brief review of the reporting requirements for Radiation Therapy Oncology Group (RTOG) 3D-CRT and IMRT protocols is also presented.

Humans↗