A floating sleeve antenna yields localized hepatic microwave ablation.

We report a novel coaxial antenna for hepatic microwave ablation. This device uses a floating sleeve, that is, a metal conductor electrically isolated from the outer connector of the antenna coaxial body, to achieve a highly localized specific absorption rate pattern that is independent of insertion depth. This floating sleeve coaxial dipole antenna has low power reflection in the 2.4-GHz IMS band. Ex vivo experiments confirm our numerical simulation results. Index Terms-Ablation, coaxial aperture antennas, finite element methods, floating sleeve, microwave heating.

Animals↗

Haemostatic partial nephrectomy using bipolar radiofrequency ablation.

OBJECTIVE: To determine whether an electrode array with a bipolar radiofrequency ablation (RFA) energy source can be used to perform a haemostatic partial nephrectomy by simultaneously ablating and coagulating renal tissue. MATERIALS AND METHODS: Lower-pole partial nephrectomy was performed in 12 porcine kidneys using a bipolar RFA system. Intraoperative ultrasonography was used to identify and avoid the collecting system. Tissues were positioned between opposing electrodes and tissue impedance monitored using a proprietary feedback and control algorithm. Ablation time and power, lesion width and length, and tissue thickness were recorded. The kidneys were assessed in vivo to show haemostasis of the remaining renal unit. Collecting system integrity was assessed with methylene blue injection, and the resected tissue analysed histologically. RESULTS: Partial nephrectomies were successful in all 12 porcine kidneys; the mean nephrectomy specimen was 3.2 x 2.6 cm. The total ablation time (sem) per lesion was 211 (15) s and the mean power was 23 W. Methylene blue injection showed an intact collecting system in 11 of the 12 kidneys, and haematoxylin and eosin staining showed a mean zone of necrosis of 9 mm at the resection margin. Ultrasonography revealed flow to the remaining kidneys after RFA and the in vivo assessment of haemostasis revealed no abnormal bleeding or haemorrhage from the kidneys. CONCLUSIONS: Applying bipolar RF energy to an electrode array can enable transmural excision of renal parenchyma in vivo in a bloodless fashion without collecting system injury.

Animals↗

In vivo measurement of swine endocardial convective heat transfer coefficient.

We measured the endocardial convective heat transfer coefficient h at 22 locations in the cardiac chambers of 15 pigs in vivo. A thin-film Pt catheter tip sensor in a Wheatstone-bridge circuit, similar to a hot wire/film anemometer, measured h. Using fluoroscopy, we could precisely locate the steerable catheter sensor tip and sensor orientation in pigs' cardiac chambers. With flows, h varies from 2500 to 9500 W/m2 x K. With zero flow, h is approximately 2400 W/m2 x K. These values of h can be used for the finite element method modeling of radiofrequency cardiac catheter ablation.

Animals↗

Noncontact radio-frequency ablation for obtaining deeper lesions.

Radio-frequency (RF) cardiac catheter ablation has been very successful for treating some cardiac arrhythmias, however, the success rate for ventricular tachycardias is still not satisfactory. Some existing methods for developing deeper lesions include active cooling of the electrode and modifying the electrode shape. We propose a method of noncontact ablation, to solve this problem. We apply 120 W of power through an 8-mm electrode for a 120-s duration, with distances from 0 to 3 mm between electrode and myocardium, to create lesions in myocardium. We apply flow rates of 1, 3, and 5 L/min to determine their effect. Results show that with an optimal distance from 0.5 to 1.5 mm between electrode and myocardium, we increase lesion depth from 7.5 mm for contact ablation to 9.5 mm for noncontact ablation. For different flow rates, the optimal distance various. The effect of flow rate is not obvious. Higher flow rate does not lead to a deeper lesion.

Animals↗

In vitro measurement of myocardial impedivity anisotropy with a miniature rectangular tube.

Due to rapid change of fiber orientation, it is difficult to measure myocardial impedivity separately in a longitudinal or transverse fiber direction without mutual influence in the two directions. Previously published values of the longitudinal and the transverse myocardial impedivity were derived indirectly from measurements that mixed the impedivity in all directions. Those values are questionable because the derivations were based on a simplified uniform myocardial fiber model. In this paper, a miniature rectangular tube was devised to facilitate direct measurement of myocardial impedivity in a uniform fiber direction. The average transverse-to-longitudinal ratio of the measured in vitro swine myocardial impedivity was about 1.66 from 1 Hz to 1 kHz and dropped to 1.25 at 1 MHz. The result is important for accurate modeling of the electrical property of myocardium in biomedical research of radio-frequency cardiac catheter ablation.

Animals↗

In-vivo measurement of swine myocardial resistivity.

We used a four-terminal plunge probe to measure myocardial resistivity in two directions at three sites from the epicardial surface of eight open-chest pigs in-vivo at eight frequencies ranging from 1 Hz to 1 MHz. We calibrated the plunge probe to minimize the error due to stray capacitance between the measured subject and ground. We calibrated the probe in saline solutions contained in a metal cup situated near the heart that had an electrical connection to the pig's heart. The mean of the measured myocardial resistivity was 319 ohm x cm at 1 Hz down to 166 ohm x cm at 1 MHz. Statistical analysis showed the measured myocardial resistivity of two out of eight pigs was significantly different from that of other pigs. The myocardial resistivity measured with the resistivity probe oriented along and across the epicardial fiber direction was significantly different at only one out of the eight frequencies. There was no significant difference in the myocardial resistivity measured at different sites.

Animals↗

Error analysis of tissue resistivity measurement.

We identified the error sources in a system for measuring tissue resistivity at eight frequencies from 1 Hz to 1 MHz using the four-terminal method. We expressed the measured resistivity with an analytical formula containing all error terms. We conducted practical error measurements with in-vivo and bench-top experiments. We averaged errors at all frequencies for all measurements. The standard deviations of error of the quantization error of the 8-bit digital oscilloscope with voltage averaging, the nonideality of the circuit, the in-vivo motion artifact and electrical interference combined to yield an error of +/- 1.19%. The dimension error in measuring the syringe tube for measuring the reference saline resistivity added +/- 1.32% error. The estimation of the working probe constant by interpolating a set of probe constants measured in reference saline solutions added +/- 0.48% error. The difference in the current magnitudes used during the probe calibration and that during the tissue resistivity measurement caused +/- 0.14% error. Variation of the electrode spacing, alignment, and electrode surface property due to the insertion of electrodes into the tissue caused +/- 0.61% error. We combined the above errors to yield an overall standard deviation error of the measured tissue resistivity of +/- 1.96%.

Animals↗

A participatory assessment of environmental health concerns in an Ojibwa community.

This research employed a participatory approach to explore environmental health (EH) concerns among Lac Courte Oreilles (LCO) Ojibwa Indians in Sawyer County, Wisconsin. The project was grounded in a broad ecological conceptualization of EH and in principles of health promotion and community participation. Community participation was accomplished through a steering committee that consisted of the primary author and LCO College faculty and community members. The selected assessment methodology was a self-administered survey mailed to LCO members in Sawyer County. Concern for environmental issues was high in this tribal community, especially for future generations. Concern was higher among older members and tribal members living on rather than off the reservation. Local environmental issues of concern were motorized water vehicles, effects from global warming, aging septic systems on waterways, unsafe driving, and contaminated lakes/streams. The LCO community can use survey results to inform further data needs and program development.