PubMed Health⌕ Search

Biomedical subjects

James B Stiehl

Publications and source records attributed to James B Stiehl.

16 recordsLinked to original sources

Morphological analysis of the proximal femur using quantitative computed tomography.

The anatomy of the proximal femur was studied in 35 specimens using quantitative computed tomography (QCT) and compared with anatomical sections studied by plane radiography and gross dissection. We found the primary supporting structure of the femoral head to be the primary compressive strut, which is a dense column of trabecular bone projecting from the pressure buttress of the medial femoral neck to the epiphyseal scar. Trabecular bone mushroomed from the epiphyseal scar and terminated at right angles to the cortex of the femoral head. We believe the primary compressive strut is the predominant load-bearing structure connecting the femoral head to the femoral neck, as many specimens lacked continuity of the head cortex to the femoral neck. Based on the CT number, the primary compressive strut had similar bone density to cortical structures such as the lesser trochanter, calcar femorale and posterior lateral femoral cortex. Ward's triangle lacked structural integrity in many cases, and we doubt the significance of tensile trabculae for sharing load. Surgical techniques such as femoral fracture fixation, resurfacing hip arthroplasty and allograft transplantation may benefit from this knowledge.

Adult↗

International multi-centre survivorship analysis of mobile bearing total knee arthroplasty.

We retrospectively reviewed the experience of a large international multi-centre study of primary total knee arthroplasty with mobile bearing design and modifications of the tibial component to allow for bicruciate preservation, posterior cruciate retention, or sacrifice. Twenty-seven surgeons performed 4,743 total knee replacements between 1981 and 1997. Implants inserted were 324 that retained both cruciate ligaments, 2,165 that retained the posterior cruciate, and 2,254 that sacrificed both cruciates. The patella was resurfaced in 2,838 and unresurfaced in 1,905. With failure defined as revision or reoperation for any reason, the overall survivorship was 79% at 16 years' follow-up. Revision occurred in 259 (5.4%) knees out of the entire cohort. The risk adjusted rates of failure were higher in females, younger patients, osteoarthritis, post-traumatic arthritis, and in patients who had a meniscal bearing prosthesis or patellar resurfacing. The most common cause of revision was bearing-related issues including chronic instability, bearing subluxation, bearing dislocation, or bearing wear in 2.3%.

Arthroplasty, Replacement, Knee↗

Extended osteotomy for periprosthetic femoral fractures in total hip arthroplasty.

Total hip arthroplasty periprosthetic fractures that involve a loose prosthesis and are located at or beyond the tip of the prosthesis are difficult to manage and have higher complication and nonunion rates. In this case report, I describe a fracture-site exposure that allows simple insertion of a long, distally fixed revision prosthesis. In an extended femoral osteotomy, the entire proximal fragment opens the upper segment in "clamshell" fashion. The proximal segment is repaired with or without femoral strut allografts and multiple cerclage wires. With this method, 7 periprosthetic fractures united successfully, and none has required further reconstruction.

Aged↗

A clinical overview patellofemoral joint and application to total knee arthroplasty.

The mechanical function of the patellofemoral joint is an integral part of knee biomechanics, and remains a primary source of important clinical entities. Force transmission is the most central issue and can be described by relevant anatomical and biomechanical principles. The brief review highlights these issues focusing on recent applications to total knee arthroplasty.

Animals↗

Trabecular metal in hip reconstructive surgery.

Biological ingrowth surfaces have become a standard prosthetic element in reconstructive hip surgery. A material's properties, three-dimensional architecture, and surface texture all play integral parts in its biological performance. Trabecular metal is an important new biomaterial that has been introduced to enhance the potential of biological ingrowth as well as provide a structural scaffold in cases of severe bone deficit. Initial clinical applications have focused on bone restoration in tumor and salvage cases and in primary and revision reconstructive cases where the increased biological fixation would be of clinical benefit. The bone ingrowth potential and mechanical integrity of this material offer exciting options for orthopedic reconstructive surgeons.

Arthroplasty, Replacement, Hip↗

Clinical results and complications in mobile-bearing total knee arthroplasty.

The low-contact stress mobile-bearing implant has the longest continuous follow-up, with over 25 years of data compiled in the designers' original study. In several peer-reviewed publications, the long-term outcome and clinical performance of the femorotibial articulation, patellar resurfacing, and various issues of surgical technique, such as cruciate retention or sacrifice, tibial axis alignment method of bone resection, cemented versus cementless implants, and the use of the lateral approach for patients with valgus deformed knees are analyzed. These results are compared with those of outcome studies of total knee arthroplasty in general. Results from a recent multicenter outcome study evaluate the survivorship results from surgeons around the world who have extensive experience with the low-contact stress implant.

Aged↗

Acute pasteurella multocida in total knee arthroplasty.

Pasturella multocida is a rare cause of joint sepsis in total joint arthroplasty, and all case reports have identified a distant source of infection from an animal bite that has caused potential hematogenous seeding of the prosthesis. We report a case in which no potential distal wound source was found and the only likely etiology was local wound seeding from an old injury. In that injury, a saddle stirrup had caused a severe traumatic soft tissue injury as a horse had rolled over the patient. We draw attention to the fact that this particular bacteria is virulent in producing septic contamination of a total joint prosthesis, and aggressive treatment is indicated when such infection is identified.

Arthritis, Infectious↗

Revascularization of a total bulk acetabular allograft at 14 years.

This case report describes the long-term outcome of a total bulk acetabular allograft placed for bone substitution after resection of recurrent pigmented villonodular synovitis of the hip joint. After 14 years in situ, the graft had completely incorporated and showed viable bleeding bone surfaces in all areas of the acetabular implant interface. The possibility of a bulk corticocancellous allograft to undergo revascularization over a long period of time has not been previously documented.

Acetabulum↗

Dislocation of the rotating platform after low contact stress total knee arthroplasty.

From a one-surgeon series of 2485 patients, we report on 10 patients with rotating platform dislocation after primary Low Contact Stress total knee arthroplasty. All dislocations occurred within 2 years of the index procedure. Of the 10 patients, nine required open reduction. Five of these patients also had exchange of the original insert. One patient was treated by closed reduction. All knees were immobilized in a cast for 8 weeks. Eight of the 10 patients had no additional dislocation and at followup (average, 35 months; range, 12 months-5 years), had a stable functional joint. Two patients had recurrent spinout of the rotating platform develop. One patient had arthrodesis whereas the other patient had the insert cemented to the tibial tray as a salvage procedure. Increasing age, a preoperative valgus deformity, and prior patellectomy were significantly associated with rotating platform spinout. Surgical experience and an improved understanding of the soft tissue constraints, particularly in the valgus knee, are important in minimizing this complication.

Aged↗

Kinematic analysis of a posterior cruciate retaining mobile-bearing total knee arthroplasty.

Using video fluoroscopy, 10 subjects having a mobile-bearing posterior cruciate-retaining total knee arthroplasty were analyzed to determine their in vivo kinematic patterns. Under weight-bearing conditions, while in extension, the average contact position was posterior to the mid-tibia sagittal plane with posterior translation of both condyles to 60 degrees of flexion, followed by anterior translation to 120 degrees of flexion. Under non-weight-bearing conditions, the average condylar contact positions were significantly more anterior from full extension to 90 degrees of knee flexion (P=.01). The average range of motion was 129 degrees under non-weight-bearing conditions and 119 degrees during weight-bearing. Although subjects in this study exhibited variable motion patterns, they are accommodated by the unconstrained optimized articulation of this highly conforming mobile-bearing implant.

Biomechanical Phenomena↗

Multicenter determination of in vivo kinematics after total knee arthroplasty.

A summation analysis of more than 70 individual kinematic studies involving normal knees and 33 different designs of total knee arthroplasty (TKA) was done with the objective of analyzing implant design variables that affect knee kinematics. Eight hundred eleven knees (733 subjects) were analyzed either during the stance phase of gait or a deep knee bend maneuver while under fluoroscopic surveillance. Fluoroscopic videotapes then were downloaded onto a workstation computer and anteroposterior (AP) femorotibial translational patterns were determined using an automated three-dimensional model fitting technique. The highest magnitude of translation was found in the normal and ACL-retaining TKA groups. Paradoxical anterior femoral translation during deep flexion was most commonly observed in PCL-retaining TKA. Substantial variability in kinematic patterns was observed in all groups. The least variability during gait was observed in mobile-bearing TKA designs, whereas posterior-stabilized TKA designs (fixed or mobile-bearing) showed the least variability during a deep knee bend. A medial pivot kinematic pattern was observed in only 55% of knees during deep knee flexion. Kinematic patterns of fixed versus mobile-bearing designs were similar with the exception of mobile-bearing TKA during gait in which femorotibial contact remained relatively stationary with minimal AP femorotibial translation.

Analysis of Variance↗

The spectrum of prosthesis design for primary total knee arthroplasty.

Many types of prostheses are currently used for total knee arthroplasty. Controversy exists, however, regarding which prostheses are the most appropriate for use by individual surgeons and specific patient groups. Six types of prostheses are currently being used in the United States for primary total knee arthroplasty: posterior cruciate ligament-retaining prostheses; posterior cruciate ligament-substituting prostheses; prostheses with ceramic components; mobile-bearing prostheses; nonmodular, compression-molded polyethylene prostheses; and medial-pivot prostheses. The historical and current result of using these different types of prostheses are discussed, and the indications, contraindications, and recommendations for each type are delineated.

Anterior Cruciate Ligament↗

Kinematic comparison of posterior cruciate sacrifice versus substitution in a mobile bearing total knee arthroplasty.

Interest in mobile bearing total knee arthroplasty (TKA) has increased significantly. The objective of this in vivo study was to analyze 2 different mobile bearing TKAs during gait and during a knee bend from 0 degrees to 90 degrees flexion. Femorotibial contact positions for 10 subjects, implanted by a single surgeon, were analyzed using videofluoroscopy. Five subjects were implanted with a posterior-stabilized mobile bearing TKA (PS), and 5 subjects were implanted with a posterior cruciate-sacrificing mobile bearing TKA (PCS). Each subject, while under fluoroscopic surveillance, performed 2 weight-bearing activities: i) normal gait and ii) deep-knee bend. This study showed that the kinematic patterns for subjects having either a PS or PCS mobile bearing TKA were similar during gait but different during a deep-knee bend. Subjects having a PS TKA experienced more posterior femoral rollback of the lateral condyle during the deep-knee bend. Findings of kinematic similarities in gait and differences in a deep-knee bend between these 2 mobile bearing designs are similar to previously published findings of fixed bearing posterior cruciate-retaining and PS TKA.

Aged↗

World experience with low contact stress mobile-bearing total knee arthroplasty: a literature review.

This article reviews recent data regarding the low contact stress (LCS) mobile-bearing total knee prosthesis recently published in the literature; conclusions are based on literature controls. The LCS Total Knee System (DePuy Orthopaedics Inc, Warsaw, Ind) has addressed the issues of implant polyethylene wear and implant-generated osteolysis. Patellar implant complications have been minimal despite the use of a mobile, metal-backed component. The original US Food and Drug Administration clinical investigation demonstrated favorable experience with cementless fixation. Results from numerous series indicate that the main problem with a mobile-bearing device is an early prosthetic failure resulting from bearing dislocation or breakage. Inadequate surgical technique will lead to femorotibial malalignment or ligamentous instability, which are factors that commonly result in revision. With the LCS Total Knee System, surgeons can use a tibia-cut-first approach with careful ligamentous balancing and flexion block spacing. The valgus lateral knee approach is an additional technique that has proved useful with this method.

Arthroplasty, Replacement, Knee↗

Accuracy of acetabular component positioning with a fluoroscopically referenced CAOS system.

OBJECTIVE: This study evaluated the accuracy, repeatability, and reproducibility of a fluoroscopic referenced system used for guiding acetabular component positioning. METHODS: Calibration of the Medtronic StealthStation Treon Plus system was performed using a Weber gage block to assess linearity. Metrologic validation of repeatability and reproducibility was done using a cadaveric pelvis with an uncemented cup placed in the target position of 45 degrees inclination and 17.5 degrees anteversion. A baseline assessment was done with a National Institute of Standards and Technology (NIST) traceable coordinate measuring machine (CMM). RESULTS: Weber gage block analysis revealed a mean bias of 0.69 mm. For the cadaveric pelvis, the anterior pelvic plane was determined using the bilateral anterior superior iliac spines with the symphysis pubis as the inferior landmark. The mean CMM measurement was inclination of 46.023 degrees (SD=1.075; range: 43.318-46.844 degrees) and anteversion of 15.787 degrees (SD=0.411; range: 15.068-16.384 degrees). One surgeon performed a repeatability assessment (n=8), finding mean inclination of 42.8 degrees (SD=1.5; range: 39.5-44.5 degrees) and anteversion of 17.5 degrees (SD=3.0; range: 14.5-22.5 degrees). Three surgeons performed a reproducibility assessment (n=24), finding mean overall inclination of 48.5 degrees (SD=0.9; range: 46-50 degrees) and anteversion of 17.8 degrees (SD=2.5; range: 13.5-23.5 degrees). All measurements were within a predefined acceptability range of+/-5 degrees. DISCUSSION: The accuracy and reproducibility of the fluoroscopic referencing method was found to be suitable for determination of cup position in the surgical setting. Anteversion measurements were more variable for the fluoroscopic method and this may be related to the difficulty for the surgeon in predictably picking the anatomical points from the fluoroscopic image.

Acetabulum↗