Electron radiotherapy: a study on dosimetric uncertainty using small cutouts.

This note investigated the dosimetric uncertainties due to the positional error when centring a small cutout to the machine central beam axis (CAX) in electron radiotherapy. A group of six circular cutouts with 4 cm diameter were made with their centres shifting 0, 2, 4, 6, 8 and 10 mm from the machine CAX for the 6 x 6 cm(2) applicator. The per cent depth doses, beam profiles and output factors were measured using the 4, 9 and 16 MeV clinical electron beams produced by a Varian 21 EX linear accelerator. The 2D isodose distributions in the z-x (or cross-line) and z-y (or in-line) plane were calculated by Monte Carlo simulation using the EGSnrc system. When the cutout centre was shifted away from the machine CAX for the 4 MeV beam, the d(m), R(80) and R(90) at the machine CAX had no significant change (<0.1 mm). For higher energies of 9 and 16 MeV beams, the d(m) was reduced by 0.45 and 1.63 mm per mm, between the cutout centre and the machine CAX with off-axis shift <6 mm respectively. R(80) and R(90) were reduced by more than 0.3 mm per mm off-axis shift for both energies. The isodose coverage of the in-line axis beam profile was reduced when the cutout centre was shifted away from machine CAX. It is important for oncology staff to note such dosimetric changes in the clinical electron radiotherapy, particularly when a high energy electron beam is used for small cutout. Such positional uncertainty is unavoidable in fabricating an electron cutout in the mould room.

Breast Neoplasms↗

Measurement for the MLC leaf velocity profile by considering the leaf leakage using a radiographic film.

A method to measure the velocity profile of a multi-leaf collimator (MLC) leaf along its travel range using a radiographic film is reported by considering the intra-leaf leakage. A specific dynamic MLC field with leaves travelling from the field edge to the isocentre line was designed. The field was used to expose a radiographic film, which was then scanned, and the dose profile along the horizontal leaf axis was measured. The velocity at a sampling point on the film can be calculated by considering the horizontal distance between the sampling point and the isocentre line, dose at the sampling point, dose rate of the linear accelerator, the total leaf travel time from the field edge to isocentre line and the pre-measured dose rate of leaf leakage. With the leaf velocities and velocity profiles for all MLC leaves measured routinely, a comprehensive and simple QA for the MLC can be set up to test the consistency of the leaf velocity performance which is essential to the IMRT delivery using a sliding window technique.

Algorithms↗

Peripheral dose outside applicators in electron beams.

The peripheral dose outside the applicators in electron beams was studied using a Varian 21 EX linear accelerator. To measure the peripheral dose profiles and point doses for the applicator, a solid water phantom was used with calibrated Kodak TL films. Peak dose spot was observed in the 4 MeV beam outside the applicator. The peripheral dose peak was very small in the 6 MeV beam and was ignorable at higher energies. Using the 10 x 10 cm(2) cutout and applicator, the dose peak for the 4 MeV beam was about 12 cm away from the field central beam axis (CAX) and the peripheral dose profiles did not change with depths measured at 0.2, 0.5 and 1 cm. The peripheral doses and profiles were further measured by varying the angle of obliquity, cutout and applicator size for the 4 MeV beam. The local peak dose was increased with about 3% per degree angle of obliquity, and was about 1% of the prescribed dose (angle of obliquity equals zero) at 1 cm depth in the phantom using the 10 x 10 cm(2) cutout and applicator. The peak dose position was also shifted 7 mm towards the CAX when the angle of obliquity was increased from 0 to 15 degrees.

Body Burden↗

Experimental verification of the application of lateral buildup ratio on the 4-MeV electron beam.

The lateral buildup ratio (LBR) used to estimate the depth dose distribution of electron beams for an irregular cutout field was obtained for a 4-MeV energy beam from a Varian 21 EX linear accelerator. The depth-dose curves for a group of circular cutout fields starting from a 2-cm diameter were measured. Electron diodes were used in a large water tank to measure the LBR values for 6, 9, 12, and 16 MeV electron beam energies and a 10 x 10 cm2 applicator. The results agreed with the published data. When the same equipment, setup, and technique were used to determine the LBR values for the 4-MeV energy beam, the values were only reasonable, being within the clinical treatment range (i.e., LBR < 1) for the smallest 6 x 6 cm2 applicator. The calculated LBR values were clinically unacceptable for the circular cutout fields with a diameter larger than 2 cm with the 10 x 10 cm2 applicator. The difficulty in the LBR measurement may be due to the significant contribution of scattered electrons from the beam defining system. This study also focused on how well the sigma values for the 4-MeV beam can predict depth-dose curves for other field sizes and whether the values are applicator-dependent.

Algorithms↗

A graphical user interface for an electron monitor unit calculator using a sector-integration algorithm and exponential curve-fitting method.

A new electron monitor unit (MU) calculator program called "eMUc" was developed to provide a convenient electron MU calculation platform for the physics and radiotherapy staff in electron radiotherapy. The program was written using the Microsoft Visual Basic.net framework and has a user-friendly front-end window with the following features: (1) Apart from using the well-known polynomial curvefitting method for the interpolation and extrapolation of relative output factors (ROFs), an exponential curve-fitting method was used to obtain better results. (2) A new algorithm was used to acquire the radius in each angular segment in the irregular electron field during the sector integration. (3) A comprehensive graphical user interface running on the Microsoft Windows operating system was used. (4) Importing irregular electron cutout field images to the calculator program was simplified by using only a commercial optical scanner. (5) Interlocks were provided when the input patient treatment parameters could not be handled by the calculator database accurately. (6) A patient treatment record could be printed out as an electronic file or hard copy and transferred to the patient database. The data acquisition mainly required ROF measurements using various circular cutouts for all the available electron energies and applicators for our Varian 21 EX linear accelerator. To verify and implement the calculator, the measured results using our specific designed irregular and clinical cutouts were compared to those predicted by the calculator. Both agreed well with an error of +/-2%.

Algorithms↗

Dosimetry limitations and a dose correction methodology for step-and-shoot IMRT.

For the step-and-shoot intensity-modulated radiation therapy (IMRT) technique, the combination of high dose rate, multiple beam segments and low dose per segment can lead to significant differences between the planned dose and the dose delivered to the patient. In this technique, a dose delivery inaccuracy known as the 'overshoot' effect is caused by the dose servo control system. This typically occurs in the first and last beam segments and causes an over- and underdose, respectively. Some dose positional error in the segment sequence is also possible there. Commercial ionization chambers (RK-type) and radiographic Kodak films were used for the measurements. The reported results were obtained using the Pinnacle(3)-V6.2 treatment planning system and a Varian Clinac 21 EX linear accelerator equipped with a 120-leaf Millennium MLC. The dose inaccuracy measurements were based on the comparison of the dose and profiles for reference fields and fields irradiated with the step-and-shoot technique. For our linear accelerators, an 'overshoot' effect ranging from 0.1 to 0.6 MU was found, corresponding to a dose rate from 100 to 600 MU min(-1), respectively. For segments with off-axis distances from 0 to 5.5 cm with >3.5 MU per segment and all dose rates, a MLC leaf-position error of <1 mm was measured. For segments with an off-axis distance of 9.5 cm, a positional error >2 mm was measured for 600 MU min(-1) and 1 MU per segment. The purpose of this study was to find a correction method for segmental dose errors caused by the 'overshoot' effect when small monitor unit and high dose rate are used. To better represent the fluctuation of the segment doses in the beam, a dose ratio between reference and step-and-shoot irradiated fields was defined. A method for the correction of segment dose inaccuracies and a quality assurance programme for the 'overshoot' effect were developed. The ordering of the biggest segment shape in the segment sequence was studied for ten randomly selected prostate patients planned for IMRT. The results of this work can be used to improve the agreement between the planned and delivered doses for IMRT.

Film Dosimetry↗

Dosimetric effects on the penumbra region of irregular multi-leaf collimated fields.

The dosimetric effect in the penumbra region for multi-leaf collimator (MLC) fields was studied using a Varian 21 EX linear accelerator. The beam profiles in the cross-line and in-line directions for MLC field configurations of varying lengths of protruded leaves, which are adjacent (on one or both sides) to the beam profile axes, were measured using a 6 MV photon beam. It was found that there is a decrease of dose in the 'edge' region of the protruded leaves' side in the cross-line profile, when the protruded leaves (upper and/or lower side) were moved out from 0.5 cm to 3 cm towards the central beam axis. When both the upper and lower portions of leaves were moved out forming a gap for the profile, the dose at the 'edge' region in the cross-line direction was decreased by about 20% and 6%, with the protruded length of leaves being 0.5 cm and 1 cm, respectively. The penumbra width of the cross-line profile increased with the protruded length of leaves when the gap width was 0.5 cm, and it was independent of the length when the width was increased larger than 1 cm. The Pinnacle treatment planning system could calculate the decrease of dose observed experimentally in the cross-line profile, but an underestimation of about 30% was found when using version 6.2b, which did not consider the leaf rounded end and tongue-and-groove effect. While the newly commissioned 7.4f, which considered the two aforementioned effects, made an improvement, it still underestimated the dose by 25% compared to the measurement. For the in-line profiles, both versions estimated the penumbra width well.

Humans↗

Study on surface dose generated in prostate intensity-modulated radiation therapy treatment.

The surface doses of 6- and 15-MV prostate intensity-modulated radiation therapy (IMRT) irradiations were measured and compared to those from a 15-MV prostate 4-beam box (FBB). IMRT plans (step-and-shoot technique) using 5, 7, and 9 beams with 6- and 15-MV photon beams were generated from a Pinnacle treatment planning system (version 6) using computed tomography (CT) scans from a Rando Phantom (ICRU Report 48). Metal oxide semiconductor field effect transistor detectors were used and placed on a transverse contour line along the Phantom surface at the central beam axis in the measurement. Our objectives were to investigate: (1) the contribution of the dynamic multileaf collimator (MLC) to the surface dose during the IMRT irradiation; (2) the effects of photon beam energy and number of beams used in the IMRT plan on the surface dose. The results showed that with the same number of beams used in the IMRT plan, the 6-MV irradiation gave more surface dose than that of 15 MV to the phantom. However, when the number of beams in the plan was increased, the surface dose difference between the above 2 photon energies became less. The average surface dose of the 15-MV IMRT irradiation increased with the number of beams in the plan, from 0.86% to 1.19%. Conversely, for 6 MV, the surface dose decreased from 1.33% to 1.24% as the beam number increased from 7 to 9. Comparing the 15-MV FBB and 6-MV IMRT plans with 2 Gy/fraction, the IMRT irradiations gave generally more surface dose, from 15% to 30%, depending on the number of beams in the plan. It was found that the increase in surface dose for the IMRT technique compared to the FBB plan was predominantly due to the number of beams and the calculated monitor units required to deliver the same dose at the isocenter in the plans. The head variation due to the dynamic MLC movement changing the surface dose distribution on the patient was reflected by the IMRT dose-intensity map. Although prostate IMRT in this study had an average higher surface dose than that of FBB, the more even distribution of relatively lower surface dose in IMRT field could avoid the big dose peaks at the surface positions directly under the FBB fields. Such an even and low surface dose distribution surrounding the patient in IMRT is believed to give less skin complication than that of FBB with the same prescribed dose.

Humans↗

IMRT: improvement in treatment planning efficiency using NTCP calculation independent of the dose-volume-histogram.

The normal tissue complication probability (NTCP) is a predictor of radiobiological effect for organs at risk (OAR). The calculation of the NTCP is based on the dose-volume-histogram (DVH) which is generated by the treatment planning system after calculation of the 3D dose distribution. Including the NTCP in the objective function for intensity modulated radiation therapy (IMRT) plan optimization would make the planning more effective in reducing the postradiation effects. However, doing so would lengthen the total planning time. The purpose of this work is to establish a method for NTCP determination, independent of a DVH calculation, as a quality assurance check and also as a mean of improving the treatment planning efficiency. In the study, the CTs of ten randomly selected prostate patients were used. IMRT optimization was performed with a PINNACLE3 V 6.2b planning system, using planning target volume (PTV) with margins in the range of 2 to 10 mm. The DVH control points of the PTV and OAR were adapted from the prescriptions of Radiation Therapy Oncology Group protocol P-0126 for an escalated prescribed dose of 82 Gy. This paper presents a new model for the determination of the rectal NTCP (R(NTCP)). The method uses a special function, named GVN (from Gy, Volume, NTCP), which describes the R(NTCP) if 1 cm3 of the volume of intersection of the PTV and rectum (R(int)) is irradiated uniformly by a dose of 1 Gy. The function was "geometrically" normalized using a prostate-prostate ratio (PPR) of the patients' prostates. A correction of the R(NTCP) for different prescribed doses, ranging from 70 to 82 Gy, was employed in our model. The argument of the normalized function is the R(int), and parameters are the prescribed dose, prostate volume, PTV margin, and PPR. The R(NTCPs) of another group of patients were calculated by the new method and the resulting difference was < +/- 5% in comparison to the NTCP calculated by the PINNACLE3 software where Kutcher's dose-response model for NTCP calculation is adopted.

Algorithms↗

Dose measurements near a non-radioactive gold seed using radiographic film.

The dose distribution near a non-radioactive gold seed under a 6 MV photon beam was measured using radiographic film, water equivalent bolus and solid water slabs. This type of small seed is typically used as a marker in target positional verification using a portal imager for conformal prostate treatment such as intensity modulated radiation therapy. A stack of three films was placed on top of the seed located on a soft bolus. Solid water slabs were then placed on top of the film. The films were exposed using a small 1x1 cm2 field. Then, using a similar experimental set-up and exposure, another stack of three films was placed under the seed, which was then covered by the soft bolus and solid water slabs. The cross-plane axial beam profiles at different depths, depending on the thickness of the film package, were measured. From the group of beam profiles above and below the seed, the dose distribution along a selected vertical line within the profiles was easily plotted. Compared to the dose with no seed at the isocentre and 5 cm of solid water, there was about a 21% increase in dose at 0.35 mm above the seed. On the other hand, there was about a 22% decrease in dose at the same distance below the seed. The dosimetry of the calibrated film was verified with a MOSFET detector. The change in dose due to the seed by varying the incident beam angles was also measured for this note.

Calibration↗

Dosimetric effect of collimating jaws for small multileaf collimated fields.

The dosimetric effects from the jaw positioned close to the small field (0.5 x 0.5, 1 x 1, and 2 x 2 cm2) side-edge generated by a single-focused multileaf collimator (MLC) were measured and studied. The measurement is important in intensity modulated radiotherapy (IMRT) because generally the jaw cannot perfectly cover all the leaf-ends in a segment of irregular field. This leads to additional dose contributed by (1) the end surface of the jaw, (2) the leaf-end, and (3) the inter- and intraleaf leakage/transmissions during the dosimetric measurement. Moreover, most of the conventional treatment planning systems ignore these effects in the dose calculation. In this study, measurements were made using a Varian 21 EX linear accelerator with 6 MV photon beam through a MLC containing 120 leaves. Percentage depth dose, beam profile, and output for small fields were measured by varying the jaw at different positions away from the leaf-ends in the field side-edge. Moving the jaw away from the leaf-ends increases the output and penumbra width for the small fields. Such increase is particularly significant when the field size is small (0.5 x 0.5 cm2) and the degree of increase changes quickly when the jaw-end is at about 1-2 cm from the leaf-end. It is suggested that measurements should be carried out in the IMRT commissioning to provide information to physicists in reviewing the treatment planning system's accuracy regarding leaf leakage/transmission and jaw effects.

Equipment Failure↗

Comparison of dose calculation algorithms with Monte Carlo methods for photon arcs.

The objective of this study is to seek an accurate and efficient method to calculate the dose distribution of a photon arc. The algorithms tested include Monte Carlo, pencil beam kernel (PK), and collapsed cone convolution (CCC). For the Monte Carlo dose calculation, EGS4/DOSXYZ was used. The SRCXYZ source code associated with the DOSXYZ was modified so that the gantry angle of a photon beam would be sampled uniformly within the arc range about an isocenter to simulate a photon arc. Specifically, photon beams (6/18 MV, 4 x 4 and 10 x 10 cm2) described by a phase space file generated by BEAM (MCPHS), or by two point sources with different photon energy spectra (MCDIV) were used. These methods were used to calculate three-dimensional (3-D) distributions in a PMMA phantom, a cylindrical water phantom, and a phantom with lung inhomogeneity. A commercial treatment planning system was also used to calculate dose distributions in these phantoms using equivalent tissue air ratio (ETAR), PK and CCC algorithms for inhomogeneity corrections. Dose distributions for a photon arc in these phantoms were measured using a RK ion chamber and radiographic films. For homogeneous phantoms, the measured results agreed well (approximately 2% error) with predictions by the Monte Carlo simulations (MCPHS and MCDIV) and the treatment planning system for the 180 degrees and 360 degrees photon arcs. For the dose distribution in the phantom with lung inhomogeneity with a 90 degrees photon arc, the Monte Carlo calculations agreed with the measurements within 2%, while the treatment planning system using ETAR, PK and CCC underestimated or overestimated the dose inside the lung inhomogeneity from 6% to 12%.

Algorithms↗