PubMed Health⌕ Search

Biomedical subjects

James Chomas

Publications and source records attributed to James Chomas.

2 recordsLinked to original sources

Detection of retained microbubbles in carotid arteries with real-time low mechanical index imaging in the setting of endothelial dysfunction.

OBJECTIVES: We sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS). BACKGROUND: Microbubbles normally pass freely through large and small vessels but are retained in regions with ED. New high-frequency low mechanical index PSS can potentially be utilized to image these retained microbubbles. METHODS: Intravenous albumin- and lipid-encapsulated microbubbles were administered in seven pigs while imaging the CAs before and after a 20% intralipid infusion to induce hypertriglyceridemia. The degree of microbubble retention was quantified by measuring endothelial acoustic intensity (AI) after clearance of free-flowing microbubbles. Microbubble adherence was also evaluated after selective balloon injury of the CAs. The CA diameter responses to acetylcholine were quantified. RESULTS: After induction of hypertriglyceridemia, adherence of albumin-encapsulated microbubbles was visually evident in all CAs, and endothelial AI increased significantly (p < 0.001 compared with baseline). The CA responses to acetylcholine went from vasodilation at baseline to vasoconstriction during hypertriglyceridemia. Endothelial AI also increased in the balloon-stretched vessels (p < 0.01 compared with uninjured vessels) after albumin-encapsulated microbubble injection, with a ring of microbubbles selectively adhering to the injured segment. This retention was not observed with lipid-encapsulated microbubbles. Scanning electron microscopy confirmed that albumin-coated microbubbles adhered to endothelial cells. CONCLUSIONS: Retention of intravenously injected albumin microbubbles occurs in the setting of both global and regional ED in large vessels and can be noninvasively imaged with high-frequency low mechanical index PSS.

Acoustics↗

Nondestructive subharmonic imaging.

Ultrasound contrast agent microbubbles are intravascular agents that can be used to estimate blood perfusion. Blood perfusion may be estimated by destroying the bubbles in a vascular bed and observing the refresh of contrast agents back into the vascular bed. Contrast agents can be readily destroyed by traditional imaging techniques. The design of a nondestructive imaging technique is necessary for the accurate quantification of contrast agent refresh. In this work, subharmonic imaging is investigated as a method for nondestructive imaging with the contrast agent microbubble MP1950 (Mallinckrodt, Inc., St. Louis, MO). Optical observation during insonation, in conjunction with a modified Rayleigh-Plesset (R-P) analysis, provides insight into the mechanisms of and parameters required for subharmonic frequency generation. Subharmonic imaging with a transmission frequency that is the same as the resonant frequency of the bubble is shown to require a minimum pressure of insonation that is greater than the experimentally-observed bubble destruction threshold. Subharmonic imaging with a transmission frequency that is twice the resonant frequency of the bubble produces a subharmonic frequency response while minimizing bubble instability. Optimization is performed using optical experimental analysis and R-P analysis.

Blood Vessels↗