PubMed Health⌕ Search

Biomedical subjects

James E Bednarz

Publications and source records attributed to James E Bednarz.

5 recordsLinked to original sources

Differential diagnosis of cardiac masses using contrast echocardiographic perfusion imaging.

OBJECTIVES: We investigated the usefulness of echocardiographic contrast perfusion imaging in differentiating cardiac masses. BACKGROUND: Two-dimensional echocardiography is the primary diagnostic modality for cardiac masses. However, differentiation between the different types of cardiac masses may be difficult at times. We hypothesized that echocardiographic contrast perfusion imaging would differentiate the neo-vascularization of malignancies from the avascularity of thrombi and the sparse vascularity of stromal tumors. METHODS: Sixteen patients with cardiac masses underwent power-modulation imaging after echocardiographic intravenous contrast administration. Pixel intensities in the mass and an adjacent section of myocardium were analyzed visually and by dedicated software. All masses had a pathologic diagnosis or resolved after anticoagulation. In a subset of patients, video-intensity curves of contrast replenishment in the mass and myocardium over time were generated. The post-impulse steady-state pixel intensity (A) and initial rate of contrast replenishment after impulse (beta) were compared with an index of blood vessel area on pathology. RESULTS: In seven of 16 patients, contrast enhancement resulted in greater pixel intensity in the mass than in the adjacent myocardium. All of these masses were classified pathologically as malignant (n = 6) or benign and vascular (n = 1). Nine masses demonstrated decreased pixel intensity, compared with the myocardium, and were diagnosed pathologically as myxomas (n = 2) or thrombi (n = 5), or they resolved with anticoagulation (n = 2). For the subset of patients, beta correlated with the vessel area index (r = 0.60). CONCLUSIONS: Echocardiographic contrast perfusion imaging aids in the differentiation of cardiac masses. Compared with the adjacent myocardium, malignant and vascular tumors hyper-enhanced, whereas stromal tumors and thrombi hypo-enhanced.

Adult↗

Automated quantitative assessment of wall motion in patients with poor acoustic windows.

BACKGROUND: No technique exists for objective evaluation of left ventricular wall motion in contrast-enhanced images. We tested a new technique for quantification of regional fractional area change using contrast-enhanced power modulation imaging with color kinesis. METHODS: The feasibility of this technique for detecting acute ischemia was first tested in 11 pigs. Next, the accuracy for detecting resting wall-motion abnormalities was determined in 52 patients requiring contrast and compared with conventional interpretation of 2-dimensional images by inexperienced readers. Expert interpretation of 2-dimensional images served as the gold standard. RESULTS: In pigs, coronary occlusion resulted in reversible hypokinesis and reduced regional fractional area change. In patients with poor acoustic windows, this technique's accuracy for quantitative detection of resting wall-motion abnormalities was 86% compared with 81% for conventional interpretation by inexperienced readers (P <.01). CONCLUSIONS: Regional wall motion can be accurately assessed using color-encoded power modulation imaging for patients requiring contrast. This technique may prove a useful diagnostic aid to echocardiographers of varying levels of experience.

Animals↗

Biplane stress echocardiography using a prototype matrix-array transducer.

BACKGROUND: Rapid image acquisition after cessation of exercise is essential for accurate stress echocardiography. Recently, a prototype matrix-array transducer has been developed that allows simultaneous acquisition of 2 imaging planes (biplane [BP] imaging). METHODS: In all, 19 healthy volunteers underwent 2 separate stress echocardiographic studies. Images were acquired in traditional 2-dimensional or BP format pre-exercise and postexercise. RESULTS: Total image acquisition time for 2-dimensional stress echocardiography was 38 +/- 8 seconds versus 29 +/- 8 seconds for BP imaging (P <.05). Heart rates were acquired closer to age-predicted maximum with BP imaging in the apical 3- and 2-chamber and parasternal long- and short-axis views (82%, 75%, 70%, 70% for BP vs 76%, 72%, 68%, 66% for 2-dimensional, respectively). CONCLUSION: BP imaging using a recently developed matrix-array probe allows more rapid imaging postexercise, resulting in acquisition of poststress images at higher heart rates without compromising image quality.

Acoustics↗

Dynamic three-dimensional color flow Doppler: an improved technique for the assessment of mitral regurgitation.

BACKGROUND: Prior studies have reconstructed mitral regurgitant flow in three dimensions displaying gray scale renditions of the jets, which were difficult to differentiate from surrounding cardiac structures. Recently, a color-coded display of three-dimensional (3D) regurgitant flow has been developed. However, this display was unable to integrate cardiac anatomy, thereby losing spatial information, which made it difficult to determine the jet origin and its spatial trajectory. To overcome this limitation, an improved method of 3D color reconstruction of regurgitant jets obtained from color flow Doppler using a transesophageal approach was developed to allow the combined display of both color flow and gray scale information. OBJECTIVES: To demonstrate the feasibility of 3D reconstruction of regurgitant mitral flow jets using an improved method of color encoding digital data acquired by transesophageal echocardiography (TEE). METHODS: We studied 46 patients undergoing a clinically indicated TEE study. All subjects had mitral regurgitation detected on a previous transthoracic study. Atrial fibrillation or poor image quality were not used as exclusion criteria. The 3D study was performed using a commercial ultrasound imaging system with a TEE probe (Sonos 5500, Agilent Technologies). A rotational mode of acquisition was used to collect two-dimensional (2D) color flow images at 3-degree intervals over 180 degrees. Images were processed off line using the Echo-View Software (TomTec Imaging Systems). Volume-rendered 3D color flow jets were displayed along with gray scale information of the adjacent cardiac structures. RESULTS: Mitral regurgitant flow, displayed in left atrial and two longitudinal orientations, was successfully reconstructed in all patients. The time for acquisition, post-processing, and rendering ranged between 10 and 15 minutes. There were 28 centrally directed jets and 15 eccentric lesions. Eight patients in the study had periprosthetic mitral regurgitant flow. CONCLUSIONS: Three-dimensional imaging of mitral regurgitant jets is feasible in the majority of patients. This improved technique provides additional information to that obtained from the 2D examination. Particularly, in patients with paravalvular leaks 3D color flow Doppler provides information on the origin and the extent of the dehiscence, as well as insight into the jet direction. In addition, in patients with eccentric mitral regurgitation, this new modality overcomes the inherent limitations of 2D echo Doppler by depicting the full extent of the jet trajectory.

Echocardiography, Doppler, Color↗

Objective assessment of left ventricular wall motion from contrast-enhanced power modulation images.

There is no method to objectively evaluate left ventricular (LV) function from contrast-enhanced images. We tested the feasibility of evaluating regional LV function by using power modulation imaging. In protocol 1, 9 anesthetized closed-chest pigs were studied. Images were obtained during contrast infusion at baseline, during LAD occlusion and reperfusion. In protocol 2, images were obtained in 20 patients (14 wall-motion abnormalities; 6 controls) during contrast enhancement. Off-line, frame-by-frame, semiautomated endocardial border detection was followed by color encoding of endocardial motion, followed by segmentation and calculation of regional fractional area changes. In all animals, coronary occlusions resulted in hypokinesis and decreased fractional area changes in LAD-related segments only, which were reversed during reperfusion. In patients, wall-motion analysis was in agreement with an expert reader of dynamic images in 92.5% segments, with interobserver variability of 12.5%. Color encoding of endocardial motion from contrast-enhanced power modulation images allows accurate quantitative assessment of regional LV function.

Aged↗