PubMed Health⌕ Search

Biomedical subjects

James E Bruce

Publications and source records attributed to James E Bruce.

15 recordsLinked to original sources

Collisionally activated dissociation and electron capture dissociation of several mass spectrometry-identifiable chemical cross-linkers.

One of the challenges in protein interaction studies with chemical cross-linking stems from the complexity of intra-, inter-, and dead-end cross-linked peptide mixtures. We have developed new cross-linkers to study protein-protein interactions with mass spectrometry to improve the ability to deal with this complexity. Even the accurate mass capabilities of FTICR-MS alone cannot unambiguously identify cross-linked peptides from cell-labeling experiments due to the complexity of these mixtures resultant from the enormous number of possible cross-linked species. We have developed novel cross-linkers that have unique fragmentation features in the gas phase. The characteristics of these cross-linkers combined with the accurate mass capability of FTICR-MS can help distinguish cross-linking reaction products and assign protein identities. These cross-linkers that we call protein interaction reporters (PIRs) have been constructed with two reactive groups attached through two bonds that can be preferentially cleaved by low-energy CID of the respective protonated precursor ions. After cleavage of the labile bonds, the middle part of the linker serves as a reporter ion to aid identification of cross-linked peptides. This report highlights three new PIRs with new features that have been developed to improve the efficiency of release of reporter ions. The new cross-linkers reported here were tuned with the addition of an affinity tag, a hydrophilic group, a photocleavable group, and new low-energy MS/MS cleavable bonds. This report presents our investigation of the MSMS fragmentation behavior of selected protonated ions of the new compounds. The comprehensive fragmentation of these PIRs and PIR-labeled cross-linked peptides with low-energy collisions and an example of electron capture dissociation in FTICR-MS is presented. These new cross-linkers will contribute to current systems biology research by allowing acquisition of global or large-scale data on protein-protein interactions.

Cross-Linking Reagents↗

A bifunctional monolithic column for combined protein preconcentration and digestion for high throughput proteomics research.

Enzymatic digestion of proteins is a key step in protein identification by mass spectrometry (MS). Traditional solution-based protein digestion methods require long incubation times and are limitations for high throughput proteomics research. Recently, solid phase digestion (e.g. trypsin immobilization on solid supports) has become a useful strategy to accelerate the speed of protein digestion and eliminate autodigestion by immobilizing and isolating the enzyme moieties on solid supports. Monolithic media is an attractive support for immobilization of enzymes due to its unique properties that include fast mass transfer, stability in most solvents, and versatility of functional groups on the surfaces of monoliths. We prepared immobilized trypsin monolithic capillaries for on-column protein digestion, analyzed the digested peptides through LC/FTICR tandem MS, and compared peptide mass fingerprinting by MALDI-TOF-MS. To further improve the digestion efficiency for low abundance proteins, we introduced C4 functional groups onto the monolith surfaces to combine on-column protein enrichment and digestion. Compared with immobilized trypsin monolithic capillaries without C4, the immobilized trypsin-C4 monolith showed improved digestion efficiency. A mechanism for increased efficiency from the combination of sample enrichment and on-column digestion is also proposed in this paper. Moreover, we investigated the effects of organic solvent on digestion and detection by comparing the observed digested peptide sequences. Our data demonstrated that all columns showed good tolerance to organic solvents and maintained reproducible enzymatic activity for at least 30 days.

Animals↗

Evaluation of low energy CID and ECD fragmentation behavior of mono-oxidized thio-ether bonds in peptides.

Thio-ether bonds in the cysteinyl side chain of peptides, formed with the most commonly used cysteine blocking reagent iodoacetamide, after conversion to sulfoxide, releases a neutral fragment mass in a low-energy MS/MS experiment in the gas phase of the mass spectrometer [6]. In this study, we show that the neutral loss fragments produced from the mono-oxidized thio-ether bonds (sulfoxide) in peptides, formed by alkyl halide or double-bond containing cysteine blocking reagents are different under low-energy MS/MS conditions. We have evaluated the low-energy fragmentation patterns of mono-oxidized modified peptides with different cysteine blocking reagents, such as iodoacetamide, 3-maleimidopropionic acid, and 4-vinylpyridine using FTICR-MS. We propose that the mechanisms of gas-phase fragmentation of mono-oxidized thio-ether bonds in the side chain of peptides, formed by iodoacetamide and double-bond containing cysteine blocking reagents, maleimide and vinylpyridine, are different because of the availability of acidic beta-hydrogens in these compounds. Moreover, we investigated the fragmentation characteristics of mono-oxidized thio-ether bonds within the peptide sequence to develop novel mass-spectrometry identifiable chemical cross-linkers. This methionine type of oxidized thio-ether bond within the peptide sequence did not show anticipated low-energy fragmentation. Electron capture dissociation (ECD) of the side chain thio-ether bond containing oxidized peptides was also studied. ECD spectra of the oxidized peptides showed a greater extent of peptide backbone cleavage, compared with CID spectra. This fragmentation information is critical to researchers for accurate data analysis of this undesired modification in proteomics research, as well as other methods that may utilize sulfoxide derivatives.

Electrons↗

Characterizing electrospray ionization using atmospheric pressure ion mobility spectrometry.

Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmospheric pressure ESI-IMS using a nanospray emitter, a striking opposite result was observed. The general tendency we observed in ESI-IMS was that higher flow rate offered higher ion signal intensity throughout a variety of conditions investigated. Thus, further efforts were undertaken to rationalize these contradictory results. It is well accepted that decreased flow rate increases both ionization efficiency and transmission efficiency, thus improving ion signal in ESI-MS. However, our study revealed that decreased flow rate results in decreased ion signal because ion transfer is constant, no matter how flow rate changes in ESI-IMS. Since ion transfer is constant in atmospheric pressure ESI-IMS, ionization efficiency can be studied independently, which otherwise is not possible in ESI-MS in which both ionization efficiency and transmission efficiency vary as conditions alter. In this article, we present a systematic study of signal intensity and ionization efficiency at various experimental conditions using ESI-IMS and demonstrate the ionization efficiency as a function of flow rate, analyte concentration, and solvent composition.

Atmospheric Pressure↗

Incorporation of a flared inlet capillary tube on a fourier transform ion cyclotron resonance mass spectrometer.

Flared inlet capillary tubes have been coupled with a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer to help the ion transmission from the atmospheric pressure to the first vacuum region. We investigated different types of atmospheric pressure ionization methods using flared inlet tubes. For most of the ionization methods, such as ESI and DESI, increased ion current transmitted from the atmospheric pressure ion source to the first stage vacuum system was observed with the use of our enhanced ion inlet designs. The corresponding ion intensity detected on a FT-ICR mass spectrometer was also observed to increase two- to fivefold using ESI or DESI with the flared tube inlet. Moreover, increased spray tip positional tolerance was observed with implementation of the flared inlet tube. We also include our preliminary results obtained by coupling AP-MALDI with flared inlet tube in this paper. For AP-MALDI, the measured ion current transferred through the flared inlet tube was about 2 to 3 times larger than the ion current through the control non-flared inlet tube.

Angiotensins↗

Observation of increased ion cyclotron resonance signal duration through electric field perturbations.

Ion motion in Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) is complex and the subject of ongoing theoretical and experimental studies. Two predominant pathways for the loss of ICR signals are thought to include damping of cyclotron motion, in which ions lose kinetic energy and radially damp toward the center of the ICR cell, and dephasing of ion coherence, in which ions of like cyclotron frequency become distributed out of phase at similar cyclotron radii. Both mechanisms result in the loss of induced ion image current in FTICR-MS measurements and are normally inseparable during time-domain signal analysis. For conventional ICR measurements which take advantage of ion ensembles, maximization of the ion population size and density can produce the desired effect of increasing phase coherence of ions during cyclotron motion. However, this approach also presents the risk of coalescence of ion packets of similar frequencies. In general, ICR researchers in the past have lacked the tools necessary to distinguish or independently control dephasing and damping mechanisms for ICR signal loss. Nonetheless, the ability to impart greater phase coherence of ions in ICR measurements will allow significant advances in FTICR-MS research by improving the current understanding of ICR signal loss contributions of dephasing and damping of ion ensembles, increasing overall time-domain signal length, and possibly, resulting in more routine ultrahigh resolution measurements. The results presented here demonstrate the ability to employ a high density electron beam to perturb electric fields within the ICR cell during detection of cyclotron motion, in an approach we call electron-promoted ion coherence (EPIC). As such, EPIC reduces ICR signal degradation through loss of phase coherence, and much longer time-domain signals can be obtained. Our results demonstrate that time-domain signals can be extended by more than a factor of 4 with the implementation of EPIC, as compared to conventional experiments with otherwise identical conditions. The application of EPIC has also been observed to reduce the appearance of peak coalescence. These capabilities are not yet fully optimized nor fully understood in terms of the complex physics that underlies the enhancement. However, the enhanced time-domain signals can result in improved resolution in frequency-domain signals, and as such, this result is important for more efficient utilization of FTICR-MS. High resolution and accurate mass analysis are prime motivating factors in the application of advanced FTICR technology. We believe the approach presented here and derivatives from it may have significant benefit in future applications of advanced FTICR technology.

Bradykinin↗

A hybrid LC-Gel-MS method for proteomics research and its application to protease functional pathway mapping.

Two-dimensional (2D) gel electrophoresis is the most common protein separation method in proteomics research. It can provide high resolution and high sensitivity. However, 2D gel methods have several limitations, such as labor-intensive procedures, poor reproducibility, and limited dynamic range of detection. In fact, many investigators have returned to couple the one-dimensional (1D) SDS-PAGE with mass spectrometry for protein identification. The limitation of this approach is the increased protein complexity in each one-dimensional gel band. To overcome this problem and provide reproducible quantitative information, we describe here a 2D method for protein mixture separation using a combination of high performance liquid chromatography (HPLC) and 1D SDS-PAGE. The study shows that the step-gradient fractionation method we have applied provides excellent reproducibility. In addition, high mass accuracy of LC-FTICR-MS can allow more confident protein identifications by high resolution and ultra-high mass measurement accuracy. This approach was applied to comparative proteomics since protein abundance level changes can be easily visualized with side-by-side vertical comparison in one gel. Furthermore, separation of multi-samples in the same gel significantly reduces run-to-run variation, as is shown with differential image gel electrophoresis (DIGE). Finally, this approach readily incorporates immunological methods to normalize relative abundances of multiple samples within a single gel. This paper presents the results of our developments and our initial application of this strategy for mapping protease function of beta amyloid cleaving enzyme (BACE) in biological systems.

Amyloid Precursor Protein Secretases↗

Proteomic identification of heat shock protein 90 as a candidate target for p53 mutation reactivation by PRIMA-1 in breast cancer cells.

INTRODUCTION: A loss of p53 function resulting from mutation is prevalent in human cancers. Thus, restoration of p53 function to mutant p53 using small compounds has been extensively studied for cancer therapy. We previously reported that PRIMA-1 (for 'p53 reactivation and induction of massive apoptosis') restored the transcriptional activity of p53 target genes in breast cancer cells with a p53 mutation. By using functional proteomics approach, we sought to identify molecular targets that are involved in the restoration of normal function to mutant p53. METHODS: PRIMA-1 treated cell lysates were subjected to immunoprecipitation with DO-1 primary antibody against p53 protein, and proteins bound to p53 were separated on a denaturing gel. Bands expressed differentially between control and PRIMA-1-treated cells were then identified by matrix-assisted laser desorption ionization-time-of-flight spectrometry. Protein expression in whole cell lysates and nuclear extracts were confirmed by Western blotting. The effect of combined treatment of PRIMA-1 and adriamycin in breast cancer cells was determined with a cytotoxicity assay in vitro. RESULTS: PRIMA-1 treated cells distinctly expressed a protein band of 90 kDa that was identified as heat shock protein 90 (Hsp90) by the analysis of the 90 kDa band tryptic digest. Immunoblotting with isoform-specific antibodies against Hsp90 identified this band as the alpha isoform of Hsp90 (Hsp90alpha). Co-immunoprecipitation with anti-Hsp90alpha antibody followed by immunoblotting with DO-1 confirmed that p53 and Hsp90alpha were interacting proteins. PRIMA-1 treatment also resulted in the translocation of Hsp90alpha to the nucleus by 8 hours. Treatment of cells with PRIMA-1 alone or in combination with adriamycin, a DNA-targeted agent, resulted in increased sensitivity of tumor cells. CONCLUSION: The studies demonstrate that PRIMA-1 restores the p53-Hsp90alpha interaction, enhances the translocation of the p53-Hsp90alpha complex and reactivates p53 transcriptional activity. Our preliminary evidence also suggests that PRIMA-1 could be considered in combination therapy with DNA-targeted agents for the treatment of breast cancer, especially for tumors with aberrant p53 function.

Amino Acid Substitution↗

Mass spectrometry identifiable cross-linking strategy for studying protein-protein interactions.

A new mass spectrometry identifiable cross-linking strategy has been developed to study protein-protein interactions. The new cross-linker was designed to have two low-energy MS/MS-cleavable bonds in the spacer chain to provide three primary benefits: First, a reporter tag can be released from cross-link due to cleavage of the two labile bonds in the spacer chain. Second, a relatively simple MS/MS spectrum can be generated owing to favorable cleavage of labile bonds. And finally, the cross-linked peptide chains are dissociated from each other, and each then can be fragmented separately to get sequence information. Therefore, this novel type of cross-linker was named protein interaction reporter (PIR). To this end, two RINK groups were utilized to make our first-generation cross-linker using solid-phase peptide synthesis chemistry. The RINK group contains a bond more labile than peptide bonds during low-energy activation. The new cross-linker was applied to cross-link ribonuclease S (RNase S), a noncovalent complex of S-peptide and S-protein. The results demonstrated that the new cross-linker effectively reacted with RNase S to generate various types of cross-linked products. More importantly, the cross-linked peptides successfully released reporter ions during selective MS/MS conditions, and the dissociated peptide chains remained intact during MS(2), thus enabling MS(3) to be performed subsequently. In addition, dead-end, intra-, and inter-cross-linked peptides can be distinguished by analyzing MS/MS spectra.

Amino Acid Sequence↗

A new maleimide-bound acid-cleavable solid-support reagent for profiling phosphorylation.

A new chemical strategy for phosphopeptide profiling is reported in this study. Phosphorylation represents one of the most important classes of posttranslational modifications of proteins. Here we report a generalized strategy that employs solid-phase capture and mass-encoding steps to selectively enrich phosphopeptides from complex mixtures. This method exploits conversion of phosphates into thiols and reactive compounds to selectively isolate products of phosphorylation. Selective isolation of phosphopeptides is achieved with a simple, novel, acid-cleavable, solid-support-bound maleimide reagent. Our chemistry efforts have focused on minimization of linker size and simplification of reagent production with incorporation of common solid-phase peptide synthesis steps. Relative quantitation was demonstrated by modifying phosphopeptides with incorporation of ethanedithiol and propanedithiol. We observed that appropriate normalization is necessary to utilize mass tag strategies for relative quantitation of posttranslational modifications. The utility of solid-phase capture was determined with model phosphopeptides, and the method was demonstrated with enriching phosphopeptides from beta-casein, alpha-casein and ovalbumin. The solid-phase capture and release methods were also demonstrated with unfractionated whole histone protein mixtures to show this compound applicability in real biological samples. The new chemical strategy will ultimately be utilized for high-throughput profiling of phosphorylation and possibly other posttranslational modifications.

Animals↗

Improved mass accuracy for tandem mass spectrometry.

With the emergence of top-down proteomics, the ability to achieve high mass measurement accuracy on tandem MS/MS data will be beneficial for protein identification and characterization. (FT-ICR) Fourier transform ion cyclotron resonance mass spectrometers are the ideal instruments to perform these experiments with their ability to provide high resolution and mass accuracy. A major limitation to mass measurement accuracy in FT-ICR instruments arises from the occurrence of space charge effects. These space charge effects shift the cyclotron frequency of the ions, which compromises the mass measurement accuracy. While several methods have been developed that correct these space charge effects, they have limitations when applied to MS/MS experiments. It has already been shown that additional information inherent in electrospray spectra can be used for improved mass measurement accuracy with the use of a computer algorithm called DeCAL (deconvolution of Coulombic affected linearity). This paper highlights a new application of the strategy for improved mass accuracy in tandem mass analysis. The results show a significant improvement in mass measurement accuracy on complex electron capture dissociation spectra of proteins. We also demonstrate how the improvement in mass accuracy can increase the confidence in protein identification from the fragment masses of proteins acquired in MS/MS experiments.

Algorithms↗

Novel mutations introduced at the beta-site of amyloid beta protein precursor enhance the production of amyloid beta peptide by BACE1 in vitro and in cells.

Abnormal production and accumulation of amyloid-beta peptide (Abeta) plays a major role in the pathogenesis of Alzheimer's disease (AD). beta-secretase (BACE1) is responsible for the cleavage at thebeta-site in amyloid beta protein precursor (AbetaPP/APP) to generate the N-terminus of Abeta. Here we report the stepwise identification and characterization of a novel APP-beta-site mutant, "NFEV" (APP_NFEV) in vitro and in cells. In vitro, the APP_NFEV exhibits 100-fold enhanced cleavage rate relative to the "wild-type" substrate (APPwt) and 10-fold increase relative to the Swedish-type mutation variant (APPsw). In cells, it was preferably cleaved among 24 APP beta-site mutations tested. More importantly, the APP_NFEV mutant failed to generate any detectable Abeta peptides in BACE1-KO mouse fibroblast cells. The production of Abeta peptides was restored by co-transfecting human BACE1, demonstrating that BACE1 is the only enzyme responsible for the processing of APP_NFEV in these cells. Analysis of APP_NFEV cleavage products secreted in the media revealed that in cells BACE1 cleaves APP_NFEV at the position between NF and EV, identical to that observed in vitro. A BACE inhibitor blocked the processing of the APP_NFEV beta-site in vitro and in cells. Our data indicates that the "NFEV" mutant is not only an enhanced substrate for BACE1 in vitro, but also a specific substrate for BACE1 in cells.

Alzheimer Disease↗

In vivo posttranslational modifications of the high mobility group A1a proteins in breast cancer cells of differing metastatic potential.

The high mobility group (HMG) proteins are important modulators of chromatin structure and gene transcription. Overexpression of HMGA1 proteins in vivo induces neoplastic transformation and promotes a highly metastatic cellular phenotype. This study focuses on characterization of HMGA1a in vivo posttranslational modification (PTM) patterns found in a nonmetastatic and two metastatic lines of MCF-7 human breast cancer cells of differing tumorigenic potential. PTM types and the amino acids on which they occur were identified by matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry. Mass analysis was restricted to MALDI peaks having less than +/-150 parts per million (ppm) error, thereby holding our analysis to a more stringent criterion than previously published work with the HMG proteins. Validation of MALDI-TOF MS analysis was accomplished utilizing electrospray ionization tandem mass spectrometry (ESI MS/MS) and manual analysis of ion fragmentation spectra. Patterns and sites of PTMs identified in this study suggest that HMGA1a proteins, like the histones, exhibit a biochemical modification "code" that relates to cellular function. For example, both increased levels of acetylation and a previously unidentified dimethylation of both lysine and arginine residues were found on HMGA1a proteins from metastatic cells compared to proteins found in their nonmetastatic precursors. Additionally, the types of modification present on lysine-45 (e.g., unmodified, acetylation, or dimethylation) varied, depending on the metastatic potential of cells. These findings suggest that examination of the PTM patterns on HMGA1 proteins may provide valuable information concerning the physiological and phenotypic state of mammalian cells.

Amino Acid Sequence↗

Beta-secretase cleavage at amino acid residue 34 in the amyloid beta peptide is dependent upon gamma-secretase activity.

The amyloid beta peptides (Abeta) are the major components of the senile plaques characteristic of Alzheimer's disease. Abeta peptides are generated from the cleavage of amyloid precursor protein (APP) by beta- and gamma-secretases. Beta-secretase (BACE), a type-I transmembrane aspartyl protease, cleaves APP first to generate a 99-amino acid membrane-associated fragment (CT99) containing the N terminus of Abeta peptides. Gamma-secretase, a multi-protein complex, then cleaves within the transmembrane region of CT99 to generate the C termini of Abeta peptides. The production of Abeta peptides is, therefore, dependent on the activities of both BACE and gamma-secretase. The cleavage of APP by BACE is believed to be a prerequisite for gamma-secretase-mediated processing. In the present study, we provide evidence both in vitro and in cells that BACE-mediated cleavage between amino acid residues 34 and 35 (Abeta-34 site) in the Abeta region is dependent on gamma-secretase activity. In vitro, the Abeta-34 site is processed specifically by BACE1 and BACE2, but not by cathepsin D, a closely related aspartyl protease. Moreover, the cleavage of the Abeta-34 site by BACE1 or BACE2 occurred only when Abeta 1- 40 peptide, a gamma-secretase cleavage product, was used as substrate, not the non-cleaved CT99. In cells, overexpression of BACE1 or BACE2 dramatically increased the production of the Abeta 1-34 species. More importantly, the cellular production of Abeta 1-34 species induced by overexpression of BACE1 or BACE2 was blocked by a number of known gamma-secretase inhibitors in a concentration-dependent manner. These gamma-secretase inhibitors had no effect on enzymatic activity of BACE1 or BACE2 in vitro. Our data thus suggest that gamma-secretase cleavage of CT99 is a prerequisite for BACE-mediated processing at Abeta-34 site. Therefore, BACE and gamma-secretase activity can be mutually dependent.

Amino Acid Sequence↗

Increased protein identification capabilities through novel tandem MS calibration strategies.

High mass measurement accuracy is critical for confident protein identification and characterization in proteomics research. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is a unique technique which can provide unparalleled mass accuracy and resolving power. However, the mass measurement accuracy of FTICR-MS can be affected by space charge effects. Here, we present a novel internal calibrant-free calibration method that corrects for space charge-induced frequency shifts in FTICR fragment spectra called Calibration Optimization on Fragment Ions (COFI). This new strategy utilizes the information from fixed mass differences between two neighboring peptide fragment ions (such as y(1) and y(2)) to correct the frequency shift after data collection. COFI has been successfully applied to LC-FTICR fragmentation data. Mascot MS/MS ion search data demonstrate that most of the fragments from BSA tryptic digested peptides can be identified using a much lower mass tolerance window after applying COFI to LC-FTICR-MS/MS of BSA tryptic digest. Furthermore, COFI has been used for multiplexed LC-CID-FTICR-MS which is an attractive technique because of its increased duty cycle and dynamic range. After the application of COFI to a multiplexed LC-CID-FTICR-MS of BSA tryptic digest, we achieved an average measured mass accuracy of 2.49 ppm for all the identified BSA fragments.

Algorithms↗