PubMed Health⌕ Search

Biomedical subjects

James F Glockner

Publications and source records attributed to James F Glockner.

26 records · Page 2Linked to original sources

Imaging of pericardial disease.

Pericardial pathology is most often identified by its effect on cardiac function. Echocardiography is usually performed first in evaluation of pericardial disease, but is occasionally limited or indeterminate. MR imaging is often helpful in these cases, offering superior soft tissue contrast and the ability to image the entire pericardium and its relationship to cardiac structure and function. Many of the techniques recently developed for myocardial imaging are equally applicable to the pericardium and frequently assist in the diagnosis of pericardial disease. In this article, the authors review MR imaging techniques for pericardial imaging, discuss the appearance of the normal pericardium, and illustrate pathologic and congenital conditions of the pericardium.

Heart Neoplasms↗

Renal structure in early autosomal-dominant polycystic kidney disease (ADPKD): The Consortium for Radiologic Imaging Studies of Polycystic Kidney Disease (CRISP) cohort.

BACKGROUND: Autosomal-dominant polycystic kidney disease (ADPKD) is characterized by gradual renal enlargement and cyst growth prior to loss of renal function. Standard radiographic imaging has not provided the resolution and accuracy necessary to detect small changes in renal volume or to reliably measure renal cyst volumes. The Consortium for Radiologic Imaging Studies in Polycystic Kidney Disease (CRISP) is longitudinally observing ADPKD individuals using high-resolution magnetic resonance (MR) imaging to determine if change in renal and cyst volumes can be detected over a short period of time, and if they correlate with decline in renal function early in disease. METHODS: Standardization studies were conducted in phantoms and four subjects at each participating clinical center. After, in the full-scale protocol, healthy ADPKD individuals 15 to 45 years old with creatinine clearance>70 mL/min underwent standardized MR renal imaging, renal iothalamate clearance, comprehensive clinical evaluation, and determination of 24-hour urinary albumin and electrolyte excretion. Stereology was used from T1-weighted images to quantify renal volume, and region-growing thresholding was used from T2-weighted images to determine cyst volume. Renal structures were evaluated in relation to demographic, clinical, and biochemical variables using means/medians, standard deviations, and Pearson correlations. RESULTS: Reliability coefficients for MR renal and cyst volume measurements in phantoms were 99.9% and 89.2%, respectively. In the full-scale protocol, 241 ADPKD individuals (145 women and 96 men) were enrolled. Total renal, cyst, and % cyst volume were significantly greater in each decade group. Hypertensive individuals demonstrated greater renal, cyst, and % cyst volume than normotensive subjects. Age-adjusted renal (r = -0.31, P < 0.0001), cyst (r = -0.36, P < 0.0001), and % cyst volume (r = -0.35, P < 0.0001) were inversely related to glomerular filtration rate (GFR). Age-adjusted renal volume (r = 0.42, P < 0.0001), cystic (r = 0.39, P < 0.0001, and % cyst volume (r = 0.41, P < 0.0001) were related with urinary albumin excretion. CONCLUSION: MR measures of renal and cyst volume are reliable and accurate in patients with ADPKD. ADPKD is characterized by significant cystic involvement that increases with age. Structure (renal and cyst volume) and function (GFR) are inversely related and directly related with the presence of hypertension and urinary albumin excretion in individuals with normal renal function.

Adolescent↗

Magnetic resonance measurements of renal blood flow as a marker of disease severity in autosomal-dominant polycystic kidney disease.

BACKGROUND: Autosomal-dominant polycystic kidney disease (ADPKD) is an inherited disorder characterized by renal cyst growth, early development of hypertension, and late occurrence of renal insufficiency. Despite evidence for the importance of nephroangiosclerosis in the progression of renal insufficiency in ADPKD, evaluation of renal blood flow (RBF) as a surrogate marker of disease severity has received little attention. METHODS: Flow phantoms and repeat RBF measurements assessed accuracy and reproducibility. One hundred twenty-seven ADPKD subjects with creatinine clearances >70 mL/min underwent measurements of RBF, total, and cyst renal volumes, and % cyst volumes by magnetic resonance (MR) and of glomerular filtration rate (GFR). Renal vascular resistance (RVR) was calculated. MR blood flow sequences utilized a two-dimensional cine phase-contrast breath-hold pulse sequence perpendicular to the renal arteries. Flow rates were calculated utilizing FLOW software. Volumetric analysis was performed using stereology and region-based thresholding. RESULTS: Excellent accuracy and intraobserver and interobserver reproducibility were demonstrated. Anatomic (total kidney volume, total cyst volume, and % cyst volume), hemodynamic (RBF and RVR), and functional (GFR) parameters were strongly correlated. Left polycystic kidneys were larger and had more severe disease. Regression analysis showed that age, diagnosis of hypertension, anatomic parameters and hemodynamic parameters were significant predictors of GFR. Multiple linear regression analysis identified age and hemodynamic parameters only as separate predictors of GFR. Anatomic, hemodynamic, and functional parameters discriminated between normotensive and hypertensive subjects despite antihypertensive treatments. CONCLUSION: Renal hemodynamic parameters measured by MR correlate with anatomic and functional indices of disease severity, are the strongest predictors of renal function, and deserve further consideration as an outcome measure in clinical trials to guide therapy in ADPKD.

Adult↗

Assessment of wall shear stress changes in arteries and veins of arteriovenous polytetrafluoroethylene grafts using magnetic resonance imaging.

The purpose of the study was to determine simultaneously the temporal changes in luminal vessel area, blood flow, and wall shear stress (WSS) in both the anastomosed artery (AA) and vein (AV) of arteriovenous polytetrafluoroethylene (PTFE) grafts. PTFE grafts were placed from the iliac artery to the ipsilateral iliac vein in 12 castrated juvenile male pigs. Contrast-enhanced magnetic resonance angiography with cine phase-contrast magnetic resonance imaging was performed. Luminal vessel area, blood flow, and WSS in the aorta, AA, AV, and inferior vena cava were determined at 3 days (D3), 7 days (D7), and 14 days (D14) after graft placement. Elastin von Gieson staining of the AV was performed. The average WSS of the AA was highest at D3 and then decreased by D7 and D14. In contrast, the average WSS and intima-to-media ratio of the AV increased from D3 to D7 and peaked by D14. Similarly, the average area of the AA was highest by D7 and began to approximate the control artery by D14. The average area of the AV had decreased to its lowest by D7. High blood flows through the AA causes a decrease in average WSS and increase in the average luminal vessel area, whereas at the AV, the average WSS and intima-to-media ratio both increase while the average luminal vessel area decreases.

Animals↗

Parallel MR imaging: a user's guide.

Parallel imaging is a recently developed family of techniques that take advantage of the spatial information inherent in phased-array radiofrequency coils to reduce acquisition times in magnetic resonance imaging. In parallel imaging, the number of sampled k-space lines is reduced, often by a factor of two or greater, thereby significantly shortening the acquisition time. Parallel imaging techniques have only recently become commercially available, and the wide range of clinical applications is just beginning to be explored. The potential clinical applications primarily involve reduction in acquisition time, improved spatial resolution, or a combination of the two. Improvements in image quality can be achieved by reducing the echo train lengths of fast spin-echo and single-shot fast spin-echo sequences. Parallel imaging is particularly attractive for cardiac and vascular applications and will likely prove valuable as 3-T body and cardiovascular imaging becomes part of standard clinical practice. Limitations of parallel imaging include reduced signal-to-noise ratio and reconstruction artifacts. It is important to consider these limitations when deciding when to use these techniques.

Artifacts↗

Navigating the aorta: MR virtual vascular endoscopy.

Virtual vascular endoscopy (VVE) uses two- and three-dimensional (3D) data sets from magnetic resonance (MR) or computed tomographic angiography to create endoluminal views of blood vessels. This technique is relatively new and has become practical only recently as cheap and powerful computers have become widely available. MR-generated VVE can produce striking images and may prove useful as an alternative or accessory means of presenting large quantities of data. This exhibit reviews technical aspects of MR VVE, describes common errors and artifacts, and provides several examples of MR VVE along with more traditional presentations of 3D gadolinium-enhanced MR angiographic data.

Aorta↗

Evaluation of cardiac valvular disease with MR imaging: qualitative and quantitative techniques.

Magnetic resonance (MR) imaging is almost never performed as the initial imaging test in cardiac valvular disease; that role is dominated by echocardiography. Nevertheless, MR imaging has much to offer in selected patients. Quantitative information regarding the severity of regurgitant or stenotic lesions can be obtained by using a combination of cine gradient-echo or steady-state free precession and cine phase-contrast sequences. In addition to providing measurements of peak velocity and flow, MR imaging is the standard of reference for evaluation of ventricular function, which can be a critical factor in determining when surgical intervention is indicated. Improvements in cardiac MR imaging technology have been particularly striking in the past few years, and these developments can easily be applied to the examination of cardiac valves. The authors briefly describe the pathophysiology of valvular disease, discuss standard MR techniques for qualitative and quantitative evaluation of valvular lesions, and illustrate these concepts with several case studies.

Heart Valve Diseases↗

Autosomal dominant polycystic kidney disease coexisting with cystic fibrosis.

Autosomal dominant polycystic kidney disease (ADPKD) is a common, inherited disorder characterized by the progressive enlargement of fluid-filled cysts in the kidneys and liver. Since the cystic fibrosis transmembrane conductance regulator (CFTR) Cl--channel may mediate the secretion of Cl--and fluid into the cysts, it is conceivable that coexisting cystic fibrosis (CF) in patients with ADPKD could attenuate their development. We previously reported that two patients with ADPKD coexisting with cystic fibrosis (CF) had a milder cystic phenotype than that of kindred without CFTR mutations. A subsequent report failed to confirm this protective effect. We now have identified another family with coexisting type 1 ADPKD and CF. The kidney volumes and the number and size of renal and hepatic cysts were markedly less in a member of this family with ADPKD (PKD1 mutation C508R) and CF (homozygous DeltaF508 mutation) than in her sister with ADPKD alone at comparable ages.

Cystic Fibrosis↗