Nanoparticle tethered antioxidant response element as a biosensor for oxygen induced toxicity in retinal endothelial cells.

PURPOSE: A novel system, based on biosensor DNA tethered to a nanoparticle, was developed for the treatment of retinopathy of prematurity. METHODS: The construction of a five-layered nanoparticle was visualized with gel electrophoresis. Transcriptionally active PCR products (TAP) containing the biosensor sequence, were bioconjugated to the surface of magnetic nanoparticles yielding biosensor tethered magnetic nanoparticles (MNP). The biosensor was based on an enhanced green fluorescent protein (EGFP) reporter gene driven by an enhanced antioxidant response element (ARE). Image analysis and flow cytometry were used to characterize MNP delivery and biosensor activity. RESULTS: The MNP penetrated dividing and migrating cells more often than quiescent endothelial cells in a wound-healing in vitro assay. Prussian blue staining demonstrated that more cells have nanoparticle cores than are transfected. When compared to naked TAP alone, MNP transfected more cells in a dose dependent manner. Both the biosensor alone and MNP induce gene expression in the presence of hyperoxia, greater than 1.5 fold over normoxic controls. These data also show that the MNP had a signal to noise ratio of 0.5 greater than the plasmid form of the biosensor as demonstrated by flow cytometry. CONCLUSIONS: This approach has the potential to allow the endothelial cells of the retinal vasculature to prevent or treat themselves after hyperoxic insult, rather than systemic treatment to protect or treat only the retina.

Animals↗

Scanning cytometry with a LEAP: laser-enabled analysis and processing of live cells in situ.

BACKGROUND: Scanning cytometry now has many of the features (and power) of multiparameter flow cytometry while keeping its own advantages as an imaging technology. Modern instruments combine capabilities of scanning cytometry with the ability to manipulate cells. A new technology, called LEAP (laser-enabled analysis and processing), offers a unique combination of capabilities in cell purification and selective macromolecule delivery (optoinjection). METHODS: LEAP-mediated cell purification and optoinjection effects were assessed in model experiments using adherent and suspension cell types and cell mixtures plated and processed at different densities. Optoinjection effects were visualized by delivering fluorescent dextrans into cells. Results were analyzed using the LEAP instrument's own imaging system as well as by fluorescence and confocal microscopy. RESULTS: Live cell samples (adherent and suspension) could be purified to 90-100% purity with 50-90% yield, causing minimal cell damage depending on the cell type and plating density. Nearly one hundred percent of the targeted cells of all cell types examined could be successfully optoinjected with dextrans of 3-70 kDa, causing no visual damage to the cells. Indirect optoinjection effects were observed on untargeted cells within 5-60 microm to targeted areas under conditions used here. CONCLUSIONS: LEAP provides solutions in cell purification and targeted macromolecule delivery for traditional and challenging applications where other methods fall short.

Animals↗

Selection of thioaptamers for diagnostics and therapeutics.

Thioaptamers offer advantages over normal phosphate ester backbone aptamers due to their enhanced affinity, specificity, and higher stability, largely due to the properties of the sulfur backbone modifications. Over the past several years, in vitro thioaptamer selection and bead-based thioaptamer selection techniques have been developed in our laboratory. Furthermore, several thioaptamers targeting specific proteins such as transcription factor NF-kappaB and AP-1 proteins have been identified. Selected thioaptamers have been shown diagnostic promise in proteome screens. Moreover, some promising thioaptamers have been shown in preliminary animal therapeutic dosing to increase survival in animal models of infection with West Nile virus.

Animals↗

Estimating cell death in G(2)M using bivariate BrdUrd/DNA flow cytometry.

BACKGROUND: In an accompanying paper (Asmuth et al.) it was found necessary to include cell death explicitly to estimate parameters of cell proliferation. The use of bivariate flow cytometry to estimate the phase durations and the doubling times of cells labeled with thymidine analogues is well established. However, these methods of analysis do not consider the possibility of cell death. This report demonstrates that estimating cell death in G(2)/M is possible. METHODS: Mathematical models for the experimental quantities, the fraction of labeled undivided cells, the fraction of labeled divided cells, and the relative movement were developed. These models include the possibility that, of the cells with G(2)/M DNA content, only a certain fraction will divide, with the remainder dying after some time T(R). Simulation studies were conducted to test the possibility of using simple methods to estimate phase durations and cell death rates. RESULTS: Cell death alters the estimates of phase transit times in a rather complex manner that depends on the lifetime of the doomed cells. However, it is still possible to obtain estimates of the phase durations of cells in S and G(2)/M and the death rates of cells in G(2)/M. CONCLUSIONS: The methods presented herein provide a new way to characterize cell populations that includes cell death rates and common measurements of cell proliferation.

Animals↗

Cell cycle kinetic dysregulation in HIV-infected normal lymphocytes.

BACKGROUND: Viruses alter cellular gene transcription and protein binding at many steps critical for cell cycle regulation to optimize the milieu for productive infection. Reasoning that virus-host cell interactions would result in perturbations of cell cycle kinetics, measurement of the duration of the phases of the cell cycle in normal T lymphocytes infected with human immunodeficiency virus (HIV) was undertaken. METHODS: Flow cytometric measurement of bromodeoxyuridine-labeled and DNA content-stained cells at multiple points through the cell cycle allowed estimation of the fraction of cells in each phase, the potential doubling-time, and the durations of S and G(2)/M phases. Separate analysis of the HIV(+) and HIV(-) populations within the infected cultures was performed based on intracellular, anti-HIV core p24 antibody labeling. A novel mathematical model, which accounted for cell loss, was developed to estimate cell cycle phases. RESULTS: (a) S phase was prolonged in the HIV-1(SF2)-infected cells compared with control. (b) This delay in S phase was due to delay in the population of cells not expressing HIV-1 antigens (p24 negative). (c) Accumulation of cells in G(2)/M phase was confirmed in HIV-1-infected cultures and was proportional to the level of infection as measured by p24 fluorescent intensity. However, all mock and HIV-1-infected populations predicted to proceed through cell division demonstrated similar G(2)/M-phase durations. (c) Potential doubling times were longer in the infected cultures; in contrast, the p24(+) subpopulations accounted for this delay. This suggests an isolated delay in the G(0)/G(1) phase for that population of cells. CONCLUSIONS: Multiple phases of host cell cycle durations were affected by HIV-1(SF2) infection in this in vitro model, suggesting novel HIV-1 pathogenesis mechanisms. Prolonged S-phase durations in HIV-1 infected/p24(-) and G(0)/G(1)-phase durations in HIV-1 infected/p24(+) subpopulations require further study to identify mechanistic pathways.

Bromodeoxyuridine↗

Ultra high-speed sorting.

BACKGROUND: Cell sorting has a history dating back approximately 40 years. The main limitation has been that, although flow cytometry is a science, cell sorting has been an art during most of this time. Recent advances in assisting technologies have helped to decrease the amount of expertise necessary to perform sorting. METHODS: Droplet-based sorting is based on a controlled disturbance of a jet stream dependent on surface tension. Sorting yield and purity are highly dependent on stable jet break-off position. System pressures and orifice diameters dictate the number of droplets per second, which is the sort rate limiting step because modern electronics can more than handle the higher cell signal processing rates. RESULTS: Cell sorting still requires considerable expertise. Complex multicolor sorting also requires new and more sophisticated sort decisions, especially when cell subpopulations are rare and need to be extracted from background. High-speed sorting continues to pose major problems in terms of biosafety due to the aerosols generated. CONCLUSIONS: Cell sorting has become more stable and predictable and requires less expertise to operate. However, the problems of aerosol containment continue to make droplet-based cell sorting problematical. Fluid physics and cell viability restraints pose practical limits for high-speed sorting that have almost been reached. Over the next 5 years there may be advances in fluidic switching sorting in lab-on-a-chip microfluidic systems that could not only solve the aerosol and viability problems but also make ultra high-speed sorting possible and practical through massively parallel and exponential staging microfluidic architectures.

Aerosols↗

Getting the right cells to the array: Gene expression microarray analysis of cell mixtures and sorted cells.

BACKGROUND: Most biological samples are cell mixtures. Some basic questions are still unanswered about analyzing these heterogeneous samples using gene expression microarray technology (MAT). How meaningful is a cell mixture's overall gene expression profile (GEP)? Is it necessary to purify the cells of interest before microarray analysis, and how much purity is needed? How much does the purification itself distort the GEP, and how well can the GEP of a small cell subset be recovered? METHODS: Model cell mixtures with different cell ratios were analyzed by both spotted and Affymetrix MAT. GEP distortion during cell purification and GEPs of purified cells were studied. CD34+ cord blood cells were purified and analyzed by MAT. RESULTS: GEPs for mixed cell populations were found to mirror the cell ratios in the mixture. Over 75% pure samples were indistinguishable from pure cells by their overall GEP. Cell purification preserved the GEP. The GEPs of small cell subsets could be accurately recovered by cell sorting both from model cell mixtures and from cord blood. CONCLUSIONS: Purification of small cell subsets from a mixture prior to MAT is necessary for meaningful results. Even completely hidden GEPs of small cell subpopulations can be recovered by cell sorting.

Blood Cells↗

Nanoparticles, molecular biosensors, and multispectral confocal microscopy.

Complex, multilayered nanoparticles hold great promise for more sophisticated drug/gene delivery systems to single cells. Outermost layers can include cell targeting and cell-entry facilitating molecules. The next layer can include intracellular targeting molecules for precise delivery of the nanoparticle complex inside the cell of interest. Molecular biosensors can be used to confirm the presence of expected molecules (for example, reactive oxygen species (ROS) as a surrogate molecule for signs of infection, or for activation in radiation damage, etc.) prior to delivery of counter-measure molecules such as drugs or gene therapy. They can also be used as a feedback control mechanism to control the proper amount of drug/gene delivery for each cell. Importantly, the full nanoparticle system can be used to prevent any cells from encountering the drug unless that cell is specifically targeted. Thus, if a cell is initially non-specifically targeted, a secondary check for other molecular targets which must also be present inside the target cell of interest can be used to catch initial targeting mistakes and prevent subsequent delivery of treatment molecules to the wrong cells. The precise intracellular location of nanoparticles within specific regions of a cell can be confirmed by 3D multispectral confocal microscopy. These single cell molecular morphology measurements can be extended from individual cells, to other cells in a tissue in tissue monolayers or tissue sections.

Biocompatible Materials↗

Immunofluorescence assay and flow-cytometry selection of bead-bound aptamers.

An immunofluorescence assay was developed to identify proteins specifically binding to oligonucleoside phosphorodithioate (ODN) aptamers from a bead-bound ODN library. Accordingly, NF-kappaB p50 protein was incubated with either bead-bound NF-kappaB consensus sequence or a bead-bound ODN combinatorial library and adsorption was then assessed using a specific primary antibody and a secondary antibody conjugated with Alexa 488 fluorescent dye. This assay avoids any problems related to fluorescently labeling target proteins. The method is straightforward and readily applicable to other transcription factors and proteins, and the feasibility of its application for high-throughput screening of large aptamer bead-based libraries by flow cytometry is demonstrated.

Binding, Competitive↗

Construction and selection of bead-bound combinatorial oligonucleoside phosphorothioate and phosphorodithioate aptamer libraries designed for rapid PCR-based sequencing.

Chemically synthesized combinatorial libraries of unmodified or modified nucleic acids have not previously been used in methods to rapidly select oligonucleotides binding to target biomolecules such as proteins. Phosphorothioate oligonucleotides (S-ODNs) or phosphorodithioate oligonucleotides (S2-ODNs) with sulfurs replacing one or both of the non-bridging phosphate oxygens bind to proteins more tightly than unmodified oligonucleotides and have the potential to be used as diagnostic reagents and therapeutics. We have applied a split synthesis methodology to create one-bead one-S-ODN and one-bead one-S2-ODN libraries. Binding and selection of specific beads to the transcription factor NF-kappaB p50/p50 protein were demonstrated. Sequencing both the nucleic acid bases and the positions of any 3'-O-thioate/dithioate linkages was carried out by using a novel PCR-based identification tag of the selected beads. This approach allows us to rapidly and conveniently identify S-ODNs or S2-ODNs that bind to proteins.

Base Sequence↗