PubMed Health⌕ Search

Biomedical subjects

James F. Greenleaf

Publications and source records attributed to James F. Greenleaf.

4 recordsLinked to original sources

Rapid Three-Dimensional Myocardial Contrast Echocardiography: Volumetric Quantitation of Nonperfused Myocardium After Intravenous Contrast Administration.

Current acquisition methods for quantitative three-dimensional myocardial contrast echocardiography require long acquisition times and therefore require the invasive administration of deposit contrast agents administered intra-arterially or into the left atrium. This study addressed the feasibility of obtaining accurate and precise quantitative volumetric measurements of nonperfused myocardium after an intravenous bolus of echocardiographic contrast agent using a rapid three-dimensional myocardial contrast echocardiographic acquisition technique. An open-chest pig model of acute left anterior descending coronary artery (LAD) occlusion was used. After LAD ligature, an intravenous bolus of contrast agent was given and images were obtained over a 12-second period using a continuously rotating transducer placed at the apical position. There was no significant microbubble destruction during the rotational acquisition period as measured by differences in mean gray scale values of apical, mid, and basal myocardial regions between the first and last image frames of acquisition. Calculated volumes of nonperfused myocardium demonstrated significant agreement and correlation (mean difference +/- SD = -0.30 +/- 1.71 cm(3); r = 0.89; P < 0.01; y = 1.06x - 1.08) with anatomic specimens. When expressed as percent of total LV volume being nonperfused, the mean difference +/- SD was 2.1 +/- 3.6%, r = 0.94, P < 0.01, and y = 1.33x - 4.08. We conclude that accurate and precise measurements of nonperfused myocardium after an acute LAD coronary artery occlusion can be obtained after the intravenous bolus administration of a contrast material when a rapid 12-second acquisition with a continuously rotating transducer is used.

Journal Article↗

Three-Dimensional Imaging Used for Virtual Dissection, Image Banking and Physical Replication of Anatomy and Physiology.

Historically, techniques of dissection have been used to aid in our understanding of human anatomy, physiology, and pathology. However, these techniques alter the structures and fine details being studied. New advances in computer technology, imaging equipment, data acquisition, processing, storage, and display now allow multidimensional imaging. Interactive computer programs can electronically display both static three-dimensional and higher-dimensional images that retain features such as motion, pressure, and temporal change. Multidimensional images can be reconstructed and manipulated using different holographic, stereolithographic, or interactive two-dimensional displays. We describe the unique potential of multidimensional reconstruction, virtual dissection, and replication of cardiovascular structures using ultrasound data. Ultrasound technology has the advantage of depicting both anatomy and physiology. The ability to perform virtual dissection and surgery in the living patient without disruption of anatomy or physiology provides the clinician with a powerful new tool for diagnosis, teaching, and therapeutics.

Journal Article↗

Three-Dimensional Echocardiography: Precision and Accuracy of Left Ventricular Volume Measurement Using Rotational Geometry with Variable Numbers of Slice Resolution.

We developed a new, rapid (6 seconds) acquisition technique allowing collection of approximately six through nine apical rotational tomograms for three-dimensional (3-D) echocardiography. To justify an appropriate sampling density for precise and accurate measurement of chamber volumes in left ventricles with complicated shape, we designed a validation study in vitro using six canine heart specimens with irregular, asymmetric left ventricles with known volumes (28.5 to 104.3 ml; mean, 71.2 ml). The number of equally spaced slices were incrementally deleted from the original high resolution scans (48 slices) to 2 slices in 3-D reconstruction. We created subgroups of 48- and 36-, 24- and 16-, 12- and 8-, 6- and 4-, and 3- and 2-component slices to compare left ventricular (LV) volumes measured in 3-D images with different slice resolution with the reference standard measured in the specimen. The accuracy and precision of LV volume were relatively constant in the subgroup of 4- and 6- through 36- and 48-component slices. When the subgroup with 6- and 4-component slices was used, the correlation was r = 0.991, P < 0.0001, root-mean-square percent error of 5.0%, bias of 0.5 +/- 3.7 ml, and interobserver variability of 5.0%. With the reduction in component slices equal or less than three, the accuracy decreased significantly (root-mean-square percent error = 8.1% and bias = -2.0 +/- 5.7 ml) compared with higher slice resolutions. This study demonstrated that 3-D echocardiography using apical rotational techniques can accurately quantify LV volume in the canine heart specimens with irregular shapes with as few as 4-6 axial slices. The rapid 3-D acquisition technique is therefore anticipated to yield precise and accurate LV volumetry.

Journal Article↗

Reference Techniques for Left Ventricular Volume Measurement by Three-Dimensional Echocardiography: Determination of Precision, Accuracy, and Feasibility.

The use of multiple in vitro reference methods to validate three-dimensional (3-D) echocardiographic techniques makes comparison difficult. In an attempt to establish a reference standard, we studied precision, accuracy, and feasibility of a true left ventricular (LV) volume measurement in six dog heart specimens using three techniques, called fluid, sheath, and cast. LV volumes ranged from 30 to 105 mL. Intraobserver variability was minimal in all combinations (1.26% to 2.8%) with a statistically insignificant tendency to higher values in the cast method. The cast method, however, exhibited significantly higher interobserver variability (5.78%) as compared to that ranging from 1.47% to 1.59% in the remaining two techniques. Regression analysis demonstrated high correlations among the three techniques assessed by 95% confidence limits and correlation coefficient (R(2) > 0.98, P < 0.01). Mean differences among the techniques (0.12 to 1.08 mL) were not significant. The fluid technique was easy to perform. The sheath technique required some practice. The cast method was sensitive to accurate preparation of a gelatin mixture. We conclude that the fluid and sheath techniques are precise, accurate, and feasible. We recommend their use as reference standards in laboratory LV volume measurement. Validation 3-D echocardiographic studies using either of these two techniques will be comparable. Although the accuracy of the cast technique is excellent, its lower precision makes it a second choice. It could be used in cases where an LV cavity cast is required and higher interobserver variability is acceptable.

Journal Article↗