PubMed Health⌕ Search

Biomedical subjects

James G Fujimoto

Publications and source records attributed to James G Fujimoto.

At least 19 recordsLinked to original sources

Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s.

We describe buffered Fourier domain mode locking (FDML), a technique for tailoring the output and multiplying the sweep rate of FDML lasers. Buffered FDML can be used to create unidirectional wavelength sweeps from the normal bidirectional sweeps in an FDML laser without sacrificing sweep rate. We also investigate the role of the laser source in dynamic range versus sensitivity performance in optical coherence tomography (OCT) imaging. Unidirectional sweep rates of 370 kHz over a 100 nm range at a center wavelength of 1300 nm are achieved. High-speed, swept-source OCT is demonstrated at record speeds of up to 370,000 axial scans per second.

Image Processing, Computer-Assisted↗

Ultra-high resolution optical coherence tomography assessment of photoreceptors in retinitis pigmentosa and related diseases.

PURPOSE: To assess photoreceptor integrity in patients with retinitis pigmentosa (RP) and related diseases using ultra-high resolution optical coherence tomography (UHR-OCT) and to correlate foveal photoreceptor loss with visual acuity. DESIGN: Observational case series. METHODS: Nine eyes of nine patients with RP and related diseases were imaged with UHR-OCT at the ophthalmology clinic. Patients were diagnosed based on history, examination, fluorescein angiography, and electroretinography. Concurrently, 36 eyes of 36 normal subjects were imaged with UHR-OCT. Central foveal thickness (CFT) and foveal outer segment/pigment epithelium thickness (FOSPET) were defined and measured on UHR-OCT images in all subjects and were compared between the two groups using unpaired t tests. The two thickness measurements in RP patients were correlated with visual acuity using Pearson correlation and linear regression. RESULTS: UHR-OCT demonstrated macular photoreceptor thinning in all RP patients. The difference in CFT between RP patients and normal subjects was not statistically significant (P = .103), but the difference in FOSPET between the two groups was significant (P = .003). Visual acuity showed a fair correlation with CFT (Pearson r = -0.43, r(2) = 0.187, P = .245) and an excellent correlation with FOSPET (Pearson r = -0.942, r(2) = 0.887, P < .0001). CONCLUSIONS: In the current study using UHR-OCT, a new thickness measurement termed FOSPET is demonstrated to quantify photoreceptor loss. FOSPET was statistically thinner in patients with RP and related diseases than in normal eyes and showed correlation with logMAR visual acuity. FOSPET appears to be a probable predictor of visual acuity in RP.

Adult↗

Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT).

INTRODUCTION: Current evidence indicates that most plaques classified as vulnerable or ruptured plaque do not lead to unstable angina or myocardial infarction. Improved methods are needed to risk stratify plaques to identify those which lead to most acute coronary syndromes. Collagen depletion in the intima overlying lipid collections appears to be a critical component of unstable plaques. In this study, we use polarization sensitive optical coherence tomography (PS-OCT) for the assessment of coronary plaque collagen. Collagen is birefringent, meaning that different polarization states travel through it at different velocities. METHODS AND RESULTS: Changes in PS-OCT images are a measure of tissue birefringence. Twenty-two coronary artery segments were imaged with PS-OCT and analyzed by picrosirius staining (a measure of collagen intensity and fiber size) and trichrome blue. The regression plot between PS-OCT changes and measured collagen yielded a correlation coefficient value of 0.475 (p<0.002). The predictive value of a PS-OCT measurement of negligible birefringence (less than 33% change) for minimal collagen was 93% while the predictive value of high birefringence (greater than 66% change) for high collagen concentrations was 89%. The effect of fiber type (chemical composition) was minimal relative to the effect due to fiber concentration. CONCLUSION: The capability of PS-OCT to assess plaque collagen content, in addition to its ability to generate high resolution structural assessments, make it a potentially powerful technology for identifying high risk plaques.

Aged↗

Normal macular thickness measurements in healthy eyes using Stratus optical coherence tomography.

OBJECTIVE: To report normal macular thickness measurements in healthy eyes using the latest commercially available optical coherence tomography (OCT) mapping software, version 3.0, from the Stratus OCT (OCT3). METHODS: Thirty-seven eyes from 37 healthy subjects underwent a complete ophthalmologic examination, including OCT. Six radial scans, 6 mm in length and centered on the fovea, were obtained using the OCT3. Retinal thickness was automatically calculated by OCT mapping software. Measurements were displayed as the mean and standard deviation for each of the 9 regions defined in the Early Treatment Diabetic Retinopathy Study. RESULTS: Foveal thickness (mean thickness in the central 1000-microm diameter area) and central foveal thickness (mean thickness at the point of intersection of 6 radial scans) on the OCT3 were 212 +/- 20 and 182 +/- 23 microm, respectively. Macular thickness measurements were thinnest at the center of the fovea, thickest within 3-mm diameter of the center, and diminished toward the periphery of the macula. The temporal quadrant was thinner than the nasal quadrant. Central foveal thickness was also manually determined as 170 +/- 18 microm, approximately 12 microm less than the value automatically obtained from the OCT3 software. There was no correlation between age and foveal thickness (P = .80). CONCLUSIONS: Mean foveal thickness measurements were 38 to 62 microm thicker than previously reported values, while mean central foveal thickness measurements were 20 to 49 microm thicker than previously published values. This discrepancy should be considered when interpreting OCT scans.

Adult↗

Ultrahigh-resolution optical coherence tomography of surgically closed macular holes.

OBJECTIVE: To evaluate retinal anatomy using ultrahigh-resolution optical coherence tomography (OCT) in eyes after successful surgical repair of full-thickness macular hole. METHODS: Twenty-two eyes of 22 patients were diagnosed as having macular hole, underwent pars plana vitrectomy, and had flat/closed macular anatomy after surgery, as confirmed with biomicroscopic and OCT examination findings. An ultrahigh-resolution-OCT system developed for retinal imaging, with the capability to achieve approximately 3-microm axial resolution, was used to evaluate retinal anatomy after hole repair. RESULTS: Despite successful closure of the macular hole, all 22 eyes had macular abnormalities on ultrahigh-resolution-OCT images after surgery. These abnormalities were separated into the following 5 categories: (1) outer foveal defects in 14 eyes (64%), (2) persistent foveal detachment in 4 (18%), (3) moderately reflective foveal lesions in 12 (55%), (4) epiretinal membranes in 14 (64%), and (5) nerve fiber layer defects in 3 (14%). CONCLUSIONS: With improved visualization of fine retinal architectural features, ultrahigh-resolution OCT can visualize persistent retinal abnormalities despite anatomically successful macular hole surgery. Outer foveal hyporeflective disruptions of the junction between the inner and outer segments of the photoreceptors likely represent areas of foveal photoreceptor degeneration. Moderately reflective lesions likely represent glial cell proliferation at the site of hole reapproximation. Thin epiretinal membranes do not seem to decrease visual acuity and may play a role in reestablishing foveal anatomy after surgery.

Aged↗

High-resolution imaging of progressive articular cartilage degeneration.

The objective of this study was to develop and verify a new technique for monitoring the progression of osteoarthritis (OA) by combining a rat model with the imaging modality optical coherence tomography (OCT). Time-sequential, in vivo, OCT imaging was performed on the left femoral condyles of 12 Wistar rats following sodium-iodoacetic acid-induced OA progression. The right femoral condyles (untreated) were also imaged and served as controls. Imaging was performed on days 0, 10, 20, 30, and 60 with an OCT system capable of acquiring images at four frames per second and an axial resolution of 5 microm. Progressive changes were analyzed using an OA scoring system. OCT successfully identified progressive cartilage degeneration as well as alteration of the cartilage/bone interface. Significant changes to both of these structures were observed in the sodium-iodoacetic acid-injected condyles. Structural changes detected with OCT were confirmed histologically. OCT in combination with a well-known model used in arthritis research represents a powerful tool for following degenerative joint disease progression in a given animal by detecting changes to the cartilage/bone interface and articular cartilage.

Animals↗

Persistence of Cloquet's canal in normal healthy eyes.

PURPOSE: Optic nerve head (ONH) structural imaging with state-of-the-art, high-speed, ultra-high-resolution optical coherence tomography (hsUHR-OCT). DESIGN: Observational cohort study. METHODS: ONH centered 3-dimensional (94,371,840 voxel measurements in a 6- x 6- x 1.4-mm tissue volume) hsUHR-OCT data were obtained in one eye from each of six males and nine females normal healthy volunteers (40 +/- 9 years of age). The presence of structures projecting anteriorly from the disk into the vitreous was noted. RESULTS: Structures were noted in 14 of 15 (93%) examined eyes, emanating from the rim of the ONH at the nasal inferior sector, presenting as thin tissue meandering into the vitreous. CONCLUSIONS: Previous technologies provided limited visualization of ONH structures. The ability to scan the entire disk using 3-dimensional OCT (3D-OCT) in a high-density raster pattern reveals a high frequency of persistence of Cloquet's canal in the normal healthy eye.

Adult↗

Redefining lamellar holes and the vitreomacular interface: an ultrahigh-resolution optical coherence tomography study.

OBJECTIVES: To define optical coherence tomographic (OCT) criteria for the diagnosis of a lamellar macular hole, and to increase understanding of lamellar hole pathogenesis by examining fine anatomic features using ultrahigh-resolution optical coherence tomography (UHR OCT). DESIGN: Retrospective observational case series. PARTICIPANTS: Nineteen eyes of 18 patients with lamellar holes were imaged with UHR OCT between 2002 and 2004. METHODS: A UHR OCT system was developed for use in the ophthalmology clinic. All 6 UHR OCT images for each eye imaged were examined. Lamellar holes were diagnosed based on a characteristic OCT appearance. Criteria for the OCT diagnosis of a lamellar hole were as follows: (1) irregular foveal contour; (2) break in the inner fovea; (3) intraretinal split; and (4) intact foveal photoreceptors. From 1205 eyes of 664 patients imaged with UHR OCT, and retrospectively reviewed, 19 eyes of 18 patients were diagnosed with a lamellar hole based on these criteria. All 19 eyes were also imaged with standard resolution OCT. Their charts were retrospectively reviewed. MAIN OUTCOME MEASURES: Standard and ultrahigh-resolution OCT images. RESULTS: On chart review, clinical diagnosis of a lamellar hole was made in only 7 of 19 eyes (37%). Twelve of 19 eyes (63%) had an epiretinal membrane (ERM) on clinical examination. Ten of 19 eyes (53%) had a posterior vitreous detachment. On UHR OCT, 17 of 19 eyes (89%) had ERMs. Eleven ERMs had an unusual thick appearance on UHR OCT. Due to poor visual acuity, 4 eyes underwent vitrectomy. Only 1 of 4 surgeries (25%) was visually and anatomically successful. Another eye improved visually, but a lamellar hole persisted. One eye progressed to a full-thickness macular hole preoperatively, which reopened after surgery. One eye developed a full-thickness hole postoperatively. CONCLUSIONS: The diagnosis of a lamellar hole can be made based on OCT criteria, which could be applied to both standard and ultrahigh-resolution OCT. The increased resolution of UHR OCT sheds light on the pathogenesis of the lamellar hole. Epiretinal membranes were visualized on UHR OCT in the majority of eyes. Many ERMs had an unusual thick appearance on UHR OCT, which may represent either trapped vitreous or posterior hyaloid, and may help stabilize retinal anatomy. Conversely, ERM contraction may play a role in lamellar hole formation. Vitrectomy surgery was anatomically and visually successful in only 1 of 4 patients, suggesting caution when performing vitrectomy on lamellar holes.

Aged↗

Ultrahigh-resolution optical coherence tomography in patients with decreased visual acuity after retinal detachment repair.

OBJECTIVE: To assess microstructural changes in the retina that may explain incomplete visual recovery after anatomically successful repair of rhegmatogenous retinal detachments (RD) using ultrahigh-resolution optical coherence tomography (UHR OCT). DESIGN: Retrospective observational case series. PARTICIPANTS: Seventeen patients with decreased visual acuity after RD repair. Twelve patients had macula-involving and 5 had macula-sparing RDs. METHODS: The UHR OCT prototype capable of approximately 3 mum axial resolution was developed for clinical use. The UHR OCT images through the center of the fovea in 17 patients with visual complaints after RD surgery were obtained. Patients were either postoperative patients from the New England Eye Center or tertiary referrals. Baseline visual acuity, preoperative lens status, location of retinal detachment, macular involvement, and postoperative visual acuity were recorded. MAIN OUTCOME MEASURES: The UHR OCT images after RD repair. RESULTS: The UHR OCT images were obtained 1 to 84 months (median, 5 months) postoperatively. The mean preoperative logarithm of the minimum angle of resolution (logMAR) visual acuity was 1.37 (Snellen equivalent, 20/390). The mean postoperative logMAR visual acuity was 0.48 (Snellen equivalent, 20/60). Anatomical abnormalities that were detected included distortion of the photoreceptor inner/outer segments (IS/OS) junction in 14 of 17 patients (82%), epiretinal membranes in 10 of 17 patients (59%), residual subretinal fluid in 3 of 17 patients (18%), and cystoid macular edema in 2 of 17 patients (12%). Of the 5 patients with preoperative macula-on detachments, 4 had distortion of the outer retina after RD repair. CONCLUSIONS: The higher resolution of UHR OCT facilitates imaging of the IS/OS junction. Therefore, UHR OCT is able to confirm prior histopathologic findings that damage to photoreceptor outer segments may occur as a consequence of retinal detachment. This may explain poor postoperative visual acuity in eyes with anatomically successful repair.

Adult↗

High-definition and 3-dimensional imaging of macular pathologies with high-speed ultrahigh-resolution optical coherence tomography.

OBJECTIVE: To assess high-speed ultrahigh-resolution optical coherence tomography (OCT) image resolution, acquisition speed, image quality, and retinal coverage for the visualization of macular pathologies. DESIGN: Retrospective cross-sectional study. PARTICIPANTS: Five hundred eighty-eight eyes of 327 patients with various macular pathologies. METHODS: High-speed ultrahigh-resolution OCT images were obtained in 588 eyes of 327 patients with selected macular diseases. Ultrahigh-resolution OCT using Fourier/spectral domain detection achieves approximately 3-mum axial image resolutions, acquisition speeds of approximately 25 000 axial scans per second, and >3 times finer resolution and >50 times higher speed than standard OCT. Three scan protocols were investigated. The first acquires a small number of high-definition images through the fovea. The second acquires a raster series of high-transverse pixel density images. The third acquires 3-dimensional OCT data using a dense raster pattern. Three-dimensional OCT can generate OCT fundus images that enable precise registration of OCT images with the fundus. Using the OCT fundus images, OCT results were correlated with standard ophthalmoscopic examination techniques. MAIN OUTCOME MEASURES: High-definition macular pathologies. RESULTS: Macular holes, age-related macular degeneration, epiretinal membranes, diabetic retinopathy, retinal dystrophies, central serous chorioretinopathy, and other pathologies were imaged and correlated with ophthalmic examination, standard OCT, fundus photography, and fluorescein angiography, where applicable. High-speed ultrahigh-resolution OCT generates images of retinal pathologies with improved quality, more comprehensive retinal coverage, and more precise registration than standard OCT. The speed preserves retinal topography, thus enabling the visualization of subtle changes associated with disease. High-definition high-transverse pixel density OCT images improve visualization of photoreceptor and pigment epithelial morphology, as well as thin intraretinal and epiretinal structures. Three-dimensional OCT enables comprehensive retinal coverage, reduces sampling errors, and enables assessment of 3-dimensional pathology. CONCLUSIONS: High-definition 3-dimensional imaging using high-speed ultrahigh-resolution OCT improves image quality, retinal coverage, and registration. This new technology has the potential to become a useful tool for elucidating disease pathogenesis and improving disease diagnosis and management.

Adult↗

Noninvasive volumetric imaging and morphometry of the rodent retina with high-speed, ultrahigh-resolution optical coherence tomography.

PURPOSE: To demonstrate high-speed, ultrahigh-resolution optical coherence tomography (OCT) for noninvasive, in vivo, three-dimensional imaging of the retina in rat and mouse models. METHODS: A high-speed, ultrahigh-resolution OCT system using spectral, or Fourier domain, detection has been developed for small animal retinal imaging. Imaging is performed with a contact lens and postobjective scanning. An axial image resolution of 2.8 mum is achieved with a spectrally broadband superluminescent diode light source with a bandwidth of approximately 150 nm at approximately 900-nm center wavelength. Imaging can be performed at 24,000 axial scans per second, which is approximately 100 times faster than previous ultrahigh-resolution OCT systems. High-definition and three-dimensional retinal imaging is performed in vivo in mouse and rat models. RESULTS: High-speed, ultrahigh-resolution OCT enabled high-definition, high transverse pixel density imaging of the murine retina and visualization of all major intraretinal layers. Raster scan protocols enabled three-dimensional volumetric imagingand comprehensive retinal segmentation algorithms allowed measurement of retinal layers. An OCT fundus image, akin to a fundus photograph was generated by axial summation of three-dimensional OCT data, thus enabling precise registration of OCT measurements to retinal fundus features. CONCLUSIONS: High-speed, ultrahigh-resolution OCT enables imaging of retinal architectural morphology in small animal models. OCT fundus images allow precise registration of OCT images and repeated measurements with respect to retinal fundus features. Three-dimensional OCT imaging enables visualization and quantification of retinal structure, which promises to allow repeated, noninvasive measurements to track disease progression, thereby reducing the need for killing the animal for histology. This capability can accelerate basic research studies in rats and mice and their translation into clinical patient care.

Animals↗

Idiopathic juxtafoveal retinal telangiectasis: new findings by ultrahigh-resolution optical coherence tomography.

OBJECTIVE: To investigate the capabilities of ultrahigh-resolution optical coherence tomography (UHR OCT); to compare with the commercially available OCT standard-resolution system, StratusOCT, for imaging of idiopathic juxtafoveal retinal telangiectasis (IJT); and to demonstrate that UHR OCT provides additional information on disease morphology, pathogenesis, and management. DESIGN: Retrospective, observational, interventional case series. PARTICIPANTS: Nineteen eyes of 10 patients diagnosed with IJT in at least one eye. METHOD: All patients were imaged with UHR OCT and StratusOCT at the same visit. A subset of patients was also imaged before and after treatment of IJT. MAIN OUTCOME MEASURES: Ultrahigh- and standard-resolution cross-sectional tomograms of IJT pathology. RESULTS: Using both standard- and ultrahigh-resolution OCT, we identified the following features of IJT: (1) a lack of correlation between retinal thickening on OCT and leakage on fluorescein angiography, (2) loss and disruption of the photoreceptor layer, (3) cystlike structures in the foveola and within internal retinal layers such as the inner nuclear or ganglion cell layers, (4) a unique internal limiting membrane draping across the foveola related to an underlying loss of tissue, (5) intraretinal neovascularization near the fovea, and (6) central intraretinal deposits and plaques. In 63% of cases, the presence of abnormal vessels and a discontinuity of the photoreceptor layer correlated with visual acuity. CONCLUSIONS: Ultrahigh-resolution OCT improves visualization of the retinal pathology associated with IJT and allows identification of new features associated with it. Some of these features, such as discontinuity of the photoreceptor layer, are revealed only by UHR OCT.

Adult↗

Comparison of ultrahigh- and standard-resolution optical coherence tomography for imaging macular pathology.

OBJECTIVE: To compare ultrahigh-resolution optical coherence tomography (UHR OCT) with standard-resolution OCT for imaging macular diseases, develop baselines for interpreting OCT images, and identify situations where UHR OCT can provide additional information on disease morphology. DESIGN: Cross-sectional study. PARTICIPANTS: One thousand two eyes of 555 patients with different macular diseases including macular hole, macular edema, central serous chorioretinopathy, age-related macular degeneration (AMD), choroidal neovascularization, epiretinal membrane, retinal pigment epithelium (RPE) detachment, and retinitis pigmentosa. METHODS: A UHR ophthalmic OCT system that achieves 3-microm axial image resolution was developed for imaging in the ophthalmology clinic. Comparative studies were performed with both UHR OCT and standard 10-microm-resolution OCT. Standard scanning protocols of 6 radial 6-mm scans through the fovea were obtained with both systems. Ultrahigh-resolution OCT and standard-resolution OCT images were correlated with standard ophthalmic examination techniques (dilated ophthalmoscopy, fluorescein angiography, indocyanine green angiograms) to assess morphological information contained in the images. MAIN OUTCOME MEASURES: Ultrahigh-resolution and standard-resolution OCT images of macular pathologies. RESULTS: Correlations of UHR OCT images, standard-resolution images, fundus examination, and/or fluorescein angiography were demonstrated in full-thickness macular hole, central serous chorioretinopathy, macular edema, AMD, RPE detachment, epiretinal membrane, vitreal macular traction, and retinitis pigmentosa. Ultrahigh-resolution OCT and standard-resolution OCT exhibited comparable performance in differentiating thicker retinal layers, such as the retinal nerve fiber, inner and outer plexiform, and inner and outer nuclear. Ultrahigh-resolution OCT had improved performance differentiating finer structures or structures with lower contrast, such as the ganglion cell layer and external limiting membrane. Ultrahigh-resolution OCT confirmed the interpretation of features, such as the boundary between the photoreceptor inner and outer segments, which is also visible in standard-resolution OCT. The improved resolution of UHR OCT is especially advantageous in assessing photoreceptor morphology. CONCLUSIONS: Ultrahigh-resolution OCT enhances the visualization of intraretinal architectural morphology relative to standard-resolution OCT. Ultrahigh-resolution OCT images can provide a baseline for defining the interpretation of standard-resolution images, thus enhancing the clinical utility of standard OCT imaging. In addition, UHR OCT can provide additional information on macular disease morphology that promises to improve understanding of disease progression and management.

Adult↗

Multiplying the repetition rate of passive mode-locked femtosecond lasers by an intracavity flat surface with low reflectivity.

By inserting a low-reflectivity flat surface inside the oscillator cavity, we demonstrate a flexible and phase-insensitive method for multiplying the repetition rate of a femtosecond passive mode-locked solid-state laser. Without mode matching and feedback control, we successfully multiplied the repetition rate of a passively mode-locked Cr:forsterite laser from 124 MHz to 1.24 GHz. High-repetition-rate femtosecond optical pulses with average power of >100 mW can be obtained with the demonstrated method.

Journal Article↗

High-resolution optical coherence tomographic imaging of osteoarthritic cartilage during open knee surgery.

This study demonstrates the first real-time imaging in vivo of human cartilage in normal and osteoarthritic knee joints at a resolution of micrometers, using optical coherence tomography (OCT). This recently developed high-resolution imaging technology is analogous to B-mode ultrasound except that it uses infrared light rather than sound. Real-time imaging with 11-microm resolution at four frames per second was performed on six patients using a portable OCT system with a handheld imaging probe during open knee surgery. Tissue registration was achieved by marking sites before imaging, and then histologic processing was performed. Structural changes including cartilage thinning, fissures, and fibrillations were observed at a resolution substantially higher than is achieved with any current clinical imaging technology. The structural features detected with OCT were evident in the corresponding histology. In addition to changes in architectural morphology, changes in the birefringent or the polarization properties of the articular cartilage were observed with OCT, suggesting collagen disorganization, an early indicator of osteoarthritis. Furthermore, this study supports the hypothesis that polarization-sensitive OCT may allow osteoarthritis to be diagnosed before cartilage thinning. This study illustrates that OCT, which can eventually be developed for use in offices or through an arthroscope, has considerable potential for assessing early osteoarthritic cartilage and monitoring therapeutic effects for cartilage repair with resolution in real time on a scale of micrometers.

Aged↗

Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma.

OBJECTIVES: To longitudinally evaluate optical coherence tomography (OCT) peripapillary retinal nerve fiber layer thickness measurements and to compare these measurements across time with clinical status and automated perimetry. METHODS: Retrospective evaluation of 64 eyes (37 patients) of glaucoma suspects or patients with glaucoma participating in a prospective longitudinal study. All participants underwent comprehensive clinical assessment, visual field (VF) testing, and OCT every 6 months. Field progression was defined as a reproducible decline of at least 2 dB in VF mean deviation from baseline. Progression of OCT was defined as reproducible mean retinal nerve fiber layer thinning of at least 20 mum. RESULTS: Each patient had a median of 5 usable OCT scans at median follow-up of 4.7 years. The difference in the linear regression slopes of retinal nerve fiber layer thickness between glaucoma suspects and patients with glaucoma was nonsignificant for all variables; however, Kaplan-Meier survival curve analysis demonstrated a higher progression rate by OCT vs VF. Sixty-six percent of eyes were stable throughout follow-up, whereas 22% progressed by OCT alone, 9% by VF mean deviation alone, and 3% by VF and OCT. CONCLUSIONS: A greater likelihood of glaucomatous progression was identified by OCT vs automated perimetry. This might reflect OCT hypersensitivity or true damage identified by OCT before detection by conventional methods.

Aged↗