PubMed Health⌕ Search

Biomedical subjects

James H Ellis

Publications and source records attributed to James H Ellis.

3 recordsLinked to original sources

Incorporating patient-centered outcomes in the analysis of cost-effectiveness: imaging strategies for renovascular hypertension.

OBJECTIVE: Our aim was to assess the contribution of patient-centered short-term disutilities and quality-of-life measures in the cost-effectiveness analysis of CT angiography, MR angiography, and conventional angiography in patients with medication-resistant hypertension. MATERIALS AND METHODS: A decision analytic model compared the life expectancy and incremental cost per life year using three initial diagnostic tests in a cohort of hypothetical individuals with medication-resistant hypertension over a range of renal artery stenosis probabilities: CT angiography (sensitivity, 96%; specificity, 96%; cost, $865); MR angiography (98%, 94%, $850); and conventional angiography (99%, 99%, $2,627). All imaging strategies were compared with a base case scenario mimicking the natural history of medication-resistant hypertension and with a scenario immediate enhanced medical therapy without prior imaging. Individuals without evidence of renal artery stenosis on initial testing underwent conventional angiography if enhanced medical therapy failed to control hypertension. Individuals diagnosed with renal artery stenosis on MR angiography required conventional angiography for definitive stent treatment ($11,1223). Blood pressure response to renal artery stenting or enhanced medical therapy varied according to blood pressure, as did the incidence of myocardial infarction and stroke resulting from hypertension. Patients who progressed to end-stage renal disease received dialysis ($60,000 per year). Quality-of-life adjustments were made for patients with hypertension, end-stage renal disease, myocardial infarction, and stroke. Short-term disutilities from undergoing an imaging test were included. The analysis accounted for direct costs derived from Medicare reimbursements and total costs derived from the literature. RESULTS: All imaging strategies were cost-effective compared with enhanced medical therapy alone or with natural history. When only direct costs were considered, MR angiography was the preferred strategy, with conventional angiography as a cost-effective alternative to MR angiography. When total costs were considered, conventional angiography dominated all other strategies. Adjusting for quality of life decreased the incremental cost-effectiveness ratios, making an already competitive strategy a more favorable alternative to the base case. Adjusting for test-related disutility did not significantly influence the cost-effectiveness of any of the imaging tests. Despite marked variation in the key clinical and cost variables, MR angiography remained the most cost-effective strategy. CONCLUSION: In the evaluation and treatment of medication-resistant hypertension, strategies that included preliminary imaging saved more lives than did the immediate institution of enhanced medical therapy at a lesser cost.

Cost-Benefit Analysis↗

Urinary tract abnormalities: initial experience with multi-detector row CT urography.

PURPOSE: To evaluate multi-detector row computed tomographic (CT) urography for detection of urinary tract abnormalities. MATERIALS AND METHODS: Sixty-five patients referred from the urology service, in whom urinary tract abnormalities were strongly suspected, underwent multi-detector row CT urography. The technique included unenhanced, nephrographic, compression, and excretory-phase images through the abdomen and pelvis. Transverse images and three-dimensional reformations were reviewed by one of two radiologists. Findings were retrospectively compared with results of urinalysis, cystoscopy and/or ureteroscopy, and/or surgery. RESULTS: Multi-detector row CT urography depicted many clinically diagnosed urinary tract abnormalities, including 15 of 16 uroepithelial malignancies, five congenital anomalies, five urinary tract calculi, and 18 calyceal and/or papillary, 30 renal pelvic and/or ureteral, and 25 bladder abnormalities. All abnormalities were detected on transverse images. These abnormalities included diffuse urothelial wall thickening in four patients (three of whom had transitional cell carcinoma), a renal abscess, a colovesical fistula, and incidentally detected extrarenal disease (a liver mass, hepatic metastases, lymph node metastases, an aortic dissection, and a pheochromocytoma; each of these findings was seen in one patient). CONCLUSION: Multi-detector row CT urography is a useful method for detecting urinary tract abnormalities.

Adult↗

Improving educational computer exhibits at radiologic meetings by modifying computer environment: results of an observational study.

An observational study of educational computer exhibits (ECEs) at the 86th Scientific Assembly and Annual Meeting of the Radiological Society of North America in 2000 was performed to determine the frequency with which the ECEs were in working order. At any given time, an average of 10% of the 71 exhibits were found to be inoperable, and, although some exhibits were functioning 100% of the time, others were not functioning up to 55% of the time. These observations underscore the importance of careful design when creating a computer-based exhibit for a meeting. Downtime of ECEs at meetings is the result of both intentional and unintentional user actions. Given that traditional poster presentations are "working" 100% of the time, modifications made to the environment of an exhibit computer to reduce downtime would be beneficial. Several relatively easy computer configuration steps can be taken that will likely improve the amount of time that an exhibit is functional. Electronic exhibits allow a more interactive experience for users and, with some assistance, will continue to be an effective educational tool.

Audiovisual Aids↗