The use of endobronchial valve device to eliminate air leak.

UNLABELLED: We evaluated an endobronchial valve device in the treatment of surgically created air leak or pneumothorax by eliminating antegrade flow. METHODS: Six sheep underwent general anesthesia with positive pressure ventilation and left thoracotomy. After division of the mediastinal pleura, the contralateral cranial lobe was identified and a 2.5 cmx1.5 cm laceration created with resultant air leak. Using bronchoscopy, we deployed a valve device in the bronchus of the injured segment. Chest drainage tube was placed and the thoracotomy closed. At 1 week (n=3) and 4 weeks (n=3), the animals underwent general anesthesia, bronchoscopy and right thoracotomy. RESULTS: All animals survived the procedure. Bronchoscopic valve device placement in the segmental bronchus resolved the air leak immediately. After closure of thoracotomy, the chest tube demonstrated minimal drainage with no air leak. At 1 and 4 weeks, bronchoscopy showed no change in device location, and the treated segments were atelectatic with fibrous scar at the injured site. CONCLUSIONS: Collapse of a selected lung segment with resolution of air leak can be achieved using bronchoscopically implanted valve device. The valve device may facilitate treatment of patients with post-surgical or post-traumatic persistent air leak.

Animals↗

Chronic mitral valve rejection requiring replacement in a nine-year-old allograft.

A 43-year-old woman underwent mitral valve replacement for severe mitral regurgitation nine years after orthotopic heart transplant. Histopathology showed chronic rejection of the mitral valve with lymphocytic infiltrates. The patient is well at one year follow-up. This report describes an identified case of chronic mitral valve rejection requiring valve replacement.

Adult↗

Beating heart catheter-based edge-to-edge mitral valve procedure in a porcine model: efficacy and healing response.

BACKGROUND: Surgical edge-to-edge repair has been used in the treatment of mitral regurgitation. We evaluated the ability of a catheter-delivered clip (Evalve, Inc) to achieve edge-to-edge mitral valve approximation without cardiopulmonary bypass and the healing response of this technique. METHODS AND RESULTS: Twenty-one pigs underwent general anesthesia and left thoracotomy. A 10F flexible delivery catheter with a clip was placed into the left atrium. With echocardiographic and fluoroscopic guidance, the clip grasped and approximated the mid portion of the anterior and posterior leaflets. After a double orifice had been confirmed, the clip was detached and the catheter withdrawn. All animals survived and had successful clip placement. Three animals were euthanized at 4 weeks, 9 at 12 weeks, 1 at 17 weeks, 7 at 24 weeks, and 1 at 52 weeks. The clip was well positioned, with leaflet approximation in all animals except 1, in which the clip separated from the posterior leaflet at 4 weeks without affecting valve function. The clip was modified and implanted in 4 pigs; all were intact at 12 to 24 weeks. Scanning electron microscopy showed clip encapsulation with complete endothelialization. Mitral stenosis and thromboembolism did not develop. Two animals developed endocarditis (1 at 12 weeks and 1 at 17 weeks). Progressive healing occurred in all other animals. CONCLUSIONS: Edge-to-edge mitral valve approximation can be successfully and reliably achieved with a catheter-delivered clip without cardiopulmonary bypass, resulting in durable healing. The success of this device supports the development of a percutaneous catheter-based system for mitral valve repair.

Animals↗

Endovascular edge-to-edge mitral valve repair: short-term results in a porcine model.

BACKGROUND: The edge-to-edge technique is an accepted method for the surgical repair of a regurgitant mitral valve. This study reports the initial use of an endovascular technology that enables a double-orifice edge-to-edge mitral valve repair without cardiopulmonary bypass in an animal model. METHODS AND RESULTS: Adult pigs (n=14) were anesthetized, and left thoracotomy was performed for epicardial echo imaging. Using femoral vein access, a steerable guide catheter was placed transseptally into the left atrium. An implantable clip designed to grasp and approximate the middle scallops of the anterior and posterior mitral leaflets was introduced through the guide catheter. The clip was opened in the left atrium, advanced through the mitral orifice, and retracted to grasp the leaflet edges. When a functional double-orifice valve was confirmed by echo, the clip was closed to coapt the leaflets and detached from the delivery catheter. Before final clip detachment, echo demonstrated a double orifice in all 14 animals. In 2 studies, the clip released from the anterior mitral leaflet. Retrospective analysis of echo images indicated an incomplete grasp of the anterior leaflet. Immediate postmortem examination revealed that the clip successfully approximated the middle scallops of the anterior and posterior leaflets in all 12 double-orifice studies. CONCLUSIONS: This study demonstrates for the first time that an endovascular system can be successfully used to perform the edge-to-edge repair technique in a nondiseased porcine model. This technique is potentially applicable as a percutaneous catheterization laboratory procedure for the treatment of mitral regurgitation in humans.

Animals↗

Acquired left ventricular-right atrial communication: Gerbode-type defect.

Left ventricular-right atrial (LV-RA) communications are rare intracardiac defects, often congenital in nature and clinically apparent during childhood. Acquired LV-RA shunts are encountered occasionally in the adult population as a result of a defect in the upper portion of the membranous ventricular septum. We describe the clinical and echocardiographic features of an elderly patient with an acquired LV-RA communication in the setting of an aortic composite valve graft and endocarditis. We also review the anatomical features and hemodynamic consequences of such defects.

Aged↗

Treatment of abdominal aortic anastomotic pseudoaneurysm with percutaneous coil embolization.

Intraabdominal anastomotic pseudoaneurysms continue to be a late complication of aortic reconstructive procedures. Early surgical repair is critical but is associated with high operative mortality rates. We present a patient who was diagnosed with a distal anastomotic pseudoaneurysm 13 months after transabdominal repair of a symptomatic abdominal aortic aneurysm. Because of the poor operative risk, the patient was considered for a less invasive approach and underwent coil embolization of the abdominal aortic anastomotic pseudoaneurysm. The patient remains without recurrence of pseudoaneurysm 3.5 years later.

Aged↗

Cardiac allograft aortic dissection: successful repair using a composite valve graft and modified-Cabrol coronary reconstruction.

We report a 55-year-old man, the recipient of a cardiac allograft for ischemic cardiomyopathy 9 years earlier, who presented with progressive aortic root dilation, worsening aortic insufficiency, and an incidentally discovered chronic type A aortic dissection limited to the donor aorta. The patient was taken to the operating room, and the aortic dissection successfully repaired using standard reoperative techniques. This is the sixth case reported in the literature, and only the fourth survivor. To our knowledge, this case represents the first successful repair, of a limited aortic dissection of the donor aorta postcardiac transplantation, using a composite valve graft and modified-Cabrol coronary reconstruction.

Aortic Dissection↗