PubMed HealthSearch

Biomedical subjects

James Lin

Publications and source records attributed to James Lin.

2 recordsLinked to original sources

Liquid biopsy for early detection of pancreatic ductal adenocarcinoma.

There is no clinically relevant blood-based assay for the detection of early-stage pancreatic ductal adenocarcinoma (PDAC), a solid malignancy characterized by poor outcomes. Here we developed, validated and tested a blood-based microRNA (miRNA) assay (which included hsa-miR-142-3p, hsa-miR-30c-5p, hsa-miR-335-5p, hsa-miR-340-5p, hsa-miR-200b-3p, hsa-miR-1260b, hsa-miR-145-3p, hsa-miR-145-5p, hsa-miR-429 and hsa-miR-200a-3p) and a composite score, PANXEON (PANcreatic cancer eXosome Early detectiON), that integrates the miRNA signature with carbohydrate antigen 19-9 for the detection of early-stage PDAC. We conducted an international, multicenter, observational, prospective biomarker study that involved 1,785 individuals with and without PDAC from four countries. The miRNA signature achieved an area under the receiver operating characteristic curve of 88.6% in the testing cohort, with a sensitivity of 83.8% for early-stage PDAC, while showing minimal cross-reactivity with other gastrointestinal cancers. In a cohort of 19 individuals, the miRNA signature levels decreased during neoadjuvant chemotherapy and after surgery and increased before disease recurrence. When combined with carbohydrate antigen 19-9 levels, this blood assay demonstrated a sensitivity of 86.8% for stage I-II PDAC, false-positive rates of 3.2% in low-risk controls and 15.6% in high-risk controls in the testing cohort. PANXEON demonstrates potential for detecting high-grade dysplasia in individuals with high-risk pancreatic cysts (64.3%). Collectively, we present a composite biomarker that may complement existing strategies for the detection of early-stage PDAC and warrants further large-scale prospective studies. ClinicalTrials.gov registration: NCT06388967 .

Journal Article

Cochlear size variation in a large-scale international multicentre cohort.

AIM: This study aims to (1) review the literature on cochlear size, measured by the A-value, to assess reported variation across studies, and (2) consolidate cochlear parameters-specifically basal turn diameter (A-value) and width (B-value)-measured using the standardized DICOM viewer OTOPLAN®, and compare these with published data. METHODS: A scoping literature review was conducted using the search term "diameter of cochlear basal turn" to identify studies reporting A-value measurements. To complement this, cochlear measurements obtained with OTOPLAN® were collected from clinical collaborators across multiple international centres. The ratio of B- to A-values, which defines the cochlear basal turn shape, was calculated as previously described by Khurayzi et al. (2021). RESULTS: The literature review identified 38 studies comprising 5,206 A-value measurements (average: 9.08 mm; range: 8.01-10.03 mm). Additionally, 5,580 OTOPLAN® measurements were collected from 43 clinics across 25 countries (mean: 9.07 mm; range: 6.67-11.45 mm). Overall, 68.7% of cochleae exhibited an elliptical basal turn shape. CONCLUSION: Using a large, international multicentre dataset and a standardized measurement tool, this study demonstrates substantial variation in cochlear size and shape across clinical cohorts from different regions. The mean A-value (9.07 mm) is consistent with previously published literature, while the wider observed range highlights greater anatomical variability within a multicentre clinical population than previously reported. The majority of cochleae demonstrate an elliptical basal turn configuration.

Humans