Surveillance of medical device-related hazards and adverse events in hospitalized patients.

CONTEXT: Although adverse drug events have been extensively evaluated by computer-based surveillance, medical device errors have no comparable surveillance techniques. OBJECTIVES: To determine whether computer-based surveillance can reliably identify medical device-related hazards (no known harm to patient) and adverse medical device events (AMDEs; patient experienced harm) and to compare alternative methods of detection of device-related problems. DESIGN, SETTING, AND PARTICIPANTS: This descriptive study was conducted from January through September 2000 at a 520-bed tertiary teaching institution in the United States with experience in using computer tools to detect and prevent adverse drug events. All 20 441 regular and short-stay patients (excluding obstetric and newborn patients) were included. MAIN OUTCOME MEASURES: Medical device events as detected by computer-based flags, telemetry problem checklists, International Classification of Diseases, Ninth Revision (ICD-9) discharge code (which could include AMDEs present at admission), clinical engineering work logs, and patient survey results were compared with each other and with routine voluntary incident reports to determine frequencies, proportions, positive predictive values, and incidence rates by each technique. RESULTS: Of the 7059 flags triggered, 552 (7.8%) indicate a device-related hazard or AMDE. The estimated 9-month incidence rates (number per 1000 admissions [95% confidence intervals]) for AMDEs were 1.6 (0.9-2.5) for incident reports, 27.7 (24.9-30.7) for computer flags, and 64.6 (60.4-69.1) for ICD-9 discharge codes. Few of these events were detected by more than 1 surveillance method, giving an overall incidence of AMDE detected by at least 1 of these methods of 83.7 per 1000 (95% confidence interval, 78.8-88.6) admissions. The positive predictive value of computer flags for detecting device-related hazards and AMDEs ranged from 0% to 38%. CONCLUSIONS: More intensive surveillance methods yielded higher rates of medical device problems than found with traditional voluntary reporting, with little overlap between methods. Several detection methods had low efficiency in detecting AMDEs. The high rate of AMDEs suggests that AMDEs are an important patient safety issue, but additional research is necessary to identify optimal AMDE detection strategies.

Adult↗

Cost of opioid-related adverse drug events in surgical patients.

Opioids have demonstrated efficacy and often are drugs of choice in the management of postoperative pain. However, their use is often limited by adverse drug events (ADEs). The objective of this study was to determine the ADE rate in adult surgical patients who received opioids and the impact of opioid ADEs on length of stay (LOS), costs, and mortality. A hospital-based computerized system detected potential ADEs. Adult patients were selected if they received at least one dose of opioid medication during a surgical hospitalization between 1 January 1990 and 31 December 1999. Control patients were matched based on matching length of stay ([LOS] at least as long as time to ADE), age (within 10 years), sex, admission year, major disease category (MDC), and without an ADE. Linear regression models were used to determine the predictors of increased LOS, total hospital costs, and log-transformed total hospital costs. 60,722 patients received opioid medication during their surgical hospitalization and 2.7% experienced an opioid-related ADE. The most common clinical manifestations were nausea and vomiting (67%), and rash, hives, or itching (33.5%). No statistically significant difference was seen in mortality between ADE/non-ADE patients. ADE patients had statistically significant increases in LOS (0.53 days) and in log-transformed cost (16%). The estimated log cost difference of 16%, if applied to the median cost patient in the non-ADE group, averaged US$ 840. Opioid-related ADEs are common in hospitalized patients and increase LOS and total hospital costs.

Economics, Pharmaceutical↗

The nonequilibrium Lorentz gas.

We study the conductivity of a Lorentz gas system, composed of a regular array of fixed scatterers and a point-like moving particle, as a function of the strength of an applied external field. In order to obtain a nonequilibrium stationary state, the speed of the point particle is fixed by the action of a Gaussian thermostat. For small fields the system is ergodic and the diffusion coefficient is well defined. We show that in this range the Periodic Orbit Expansion can be successfully applied to compute the values of the thermodynamic variables. At larger values of the field we observe a variety of possible dynamics, including the breakdown of ergodic behavior, and later the existence of a single stable trajectory for the largest fields. We also study the behavior of the system as a function of the orientation of the array of scatterers with respect to the external field. Finally, we present a detailed dynamical study of the transitions in the bifurcation sequence in both the elementary cell and the fundamental domain. The consequences of this behavior for the ergodicity of the system are explored. (c) 1995 American Institute of Physics.

Journal Article↗