Short-term and long-term reproducibility of lung tumor position using active breathing control (ABC).

PURPOSE: To evaluate the short-term and long-term reproducibility of lung tumor position for scans acquired using an active breathing control (ABC) device. METHODS AND MATERIALS: Ten patients with lung cancer were scanned over three sessions during the course of treatment. For each session, two scans were acquired at deep inhale, and one scan each at half of deep inhale and at exhale. Long-term reproducibility was evaluated by comparing the same breathing state scans from two sessions, with setup variation removed by skeletal alignment. Tumor alignment was based on intensity matching of a small volume around the tumor. For short-term reproducibility, the two inhale volumes from the same session were compared. RESULTS: For the short-term reproducibility, the mean and the standard deviation (SD) of the displacement of the center of tumor were 0.0 (1.5) mm in anteroposterior (AP), 0.3 (1.4) mm in superior/inferior (SI), and 0.2 (0.7) mm in right/left (RL) directions. For long-term reproducibility, the mean (SD) were -1.3 (3.1) mm AP, -0.5 (3.8) mm SI, and 0.3 (1.6) mm RL for inhale and -0.2 (2.8) mm AP, 0.2 (2.1) mm SI, and -0.7 (1.1) mm RL for exhale. CONCLUSION: The ABC device demonstrates very good short-term and long-term reproducibility. Increased long-term variability in position, primarily in the SI and AP directions, indicates the role of tumor-directed localization in combination with breath-held immobilization.

Carcinoma, Non-Small-Cell Lung↗

Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer.

PURPOSE: The Calypso 4D Localization System is being developed to provide accurate, precise, objective, and continuous target localization during radiotherapy. This study involves the first human use of the system, to evaluate the localization accuracy of this technique compared with radiographic localization and to assess its ability to obtain real-time prostate-motion information. METHODS AND MATERIALS: Three transponders were implanted in each of 20 patients. Eleven eligible patients of the 20 patients participated in a study arm that compared radiographic triangulated transponder locations to electromagnetically recorded transponder locations. Transponders were tracked for 8-min periods. RESULTS: The implantations were all successful, with no major complications. Intertransponder distances were largely stable. Comparison of the patient localization on the basis of transponder locations as per the Calypso system with the radiographic transponder localization showed an average (+/-SD) 3D difference of 1.5 +/- 0.9 mm. Upon tracking during 8 min, 2 of the 11 patients showed significant organ motion (>1 cm), with some motion lasting longer that 1 min. CONCLUSION: Calypso transponders can be used as magnetic intraprostatic fiducials. Clinical evaluation of this novel 4D nonionizing electromagnetic localization system with transponders indicates a comparable localization accuracy to isocenter, (within 2 mm) compared with X-ray localization.

Electromagnetic Phenomena↗

Influence of intrafraction motion on margins for prostate radiotherapy.

PURPOSE: To assess the impact of intrafraction intervention on margins for prostate radiotherapy. METHODS AND MATERIALS: Eleven supine prostate patients with three implanted transponders were studied. The relative transponder positions were monitored for 8 min and combined with previously measured data on prostate position relative to skin marks. Margins were determined for situations of (1) skin-based positioning, and (2) pretreatment transponder positioning. Intratreatment intervention was simulated assuming conditions of (1) continuous tracking, and (2) a 3-mm threshold for position correction. RESULTS: For skin-based setup without and with inclusion of intrafraction motion, prostate treatments would have required average margins of 8.0, 7.3, and 10.0 mm and 8.2, 10.2, and 12.5 mm, about the left-right, anterior-posterior, and cranial-caudal directions, respectively. Positioning by prostate markers at the start of the treatment fraction reduced these values to 1.8, 5.8, and 7.1 mm, respectively. Interbeam adjustment further reduced margins to an average of 1.4, 2.3, and 1.8 mm. Intrabeam adjustment yielded margins of 1.3, 1.5, and 1.5 mm, respectively. CONCLUSION: Significant reductions in margins might be achieved by repositioning the patient before each beam, either radiographically or electromagnetically. However, 2 of the 11 patients would have benefited from continuous target tracking and threshold-based intervention.

Algorithms↗

Exploring breathing pattern irregularity with projection-based method.

Accurate descriptions of organ motion due to breathing are highly desirable for radiation treatment planning. This paper proposes an index that quantifies the irregularity of a signal related to respiratory motion. The method works by finding the periodic band-limited signal that best fits the signal samples, and then computing the root mean squared (RMS) residual error. The fitted signal itself may be useful for treatment planning. Using clinical data describing amplitude-time relationships (RPM, Varian) from twelve patients, we correlated the proposed index against relevant metrics from various treatment planning schemes. Simulation results demonstrate a reasonable match with all treatment methods considered, suggesting that the proposed irregularity index is suitable for a variety of treatment methods. Compared to the modified cosine function, which was investigated previously for breathing pattern models, the proposed approach is more representative, flexible, and computationally efficient.

Algorithms↗

A practical approach for quantitative estimates of voxel-by-voxel liver perfusion using DCE imaging and a compartmental model.

Voxel-by-voxel estimation of liver perfusion using nonlinear least-squares fits of dynamic contrast enhanced computed tomography or magnetic resonance imaging data to a compartmental model is a computational expensive process. In this report, a "linear" least-squares method for estimation of liver perfusion is described. Simulated data and the data from an example case of a patient with intrahepatic cancer are presented. Compared to the nonlinear method, the new method can improve computational speed by a factor of approximately 400, which makes it practical for use in clinical trials.

Algorithms↗

The management of respiratory motion in radiation oncology report of AAPM Task Group 76.

This document is the report of a task group of the AAPM and has been prepared primarily to advise medical physicists involved in the external-beam radiation therapy of patients with thoracic, abdominal, and pelvic tumors affected by respiratory motion. This report describes the magnitude of respiratory motion, discusses radiotherapy specific problems caused by respiratory motion, explains techniques that explicitly manage respiratory motion during radiotherapy and gives recommendations in the application of these techniques for patient care, including quality assurance (QA) guidelines for these devices and their use with conformal and intensity modulated radiotherapy. The technologies covered by this report are motion-encompassing methods, respiratory gated techniques, breath-hold techniques, forced shallow-breathing methods, and respiration-synchronized techniques. The main outcome of this report is a clinical process guide for managing respiratory motion. Included in this guide is the recommendation that tumor motion should be measured (when possible) for each patient for whom respiratory motion is a concern. If target motion is greater than 5 mm, a method of respiratory motion management is available, and if the patient can tolerate the procedure, respiratory motion management technology is appropriate. Respiratory motion management is also appropriate when the procedure will increase normal tissue sparing. Respiratory motion management involves further resources, education and the development of and adherence to QA procedures.

Guidelines as Topic↗

Evaluating the influence of setup uncertainties on treatment planning for focal liver tumors.

PURPOSE: A mechanism has been developed to evaluate the influence of random setup variations on dose during treatment planning. The information available for studying these factors shifts from population-based models toward patient-specific data as treatment progresses and setup measurements for an individual patient become available. This study evaluates the influence of population as well as patient-specific setup distributions on treatment plans for focal liver tumors. METHODS AND MATERIALS: Eight patients with focal liver tumors were treated on a protocol that involved online setup measurement and adjustment, as well as ventilatory immobilization. Summary statistics from these three-dimensional conformal treatments yielded individual and population distributions of position at initial setup for each fraction. A convolution model for evaluation of the influence of random setup variation on calculated dose distributions has been previously described and investigated for application to focal liver radiotherapy by our department. Individual patient doses based on initial setup positions were calculated by convolving the calculated dose distribution with an anisotropic probability distribution function representing the individual patient's random variations. A separate convolution using population-averaged random variations was performed. Individual beam apertures were then adjusted to provide plans that ensured proper dose to the clinical target volume following convolution with population distributions, as well as individual patient position uncertainty models. RESULTS: Individual patient setup distributions for the course of treatment had random setup variations (sigma) that ranged from 2.5 to 5.7 mm (left-right), 2.1 to 8.3 mm (anterior-posterior), and 4.1 to 10.8 mm (cranial-caudal). The population random components were 4.2 mm (left-right), 4.1 mm (anterior-posterior), and 7.0 mm (cranial-caudal) at initial setup. The initial static planned dose distribution overestimated the volume of liver irradiated to high doses, because inclusion of setup uncertainties generally blurred the resulting doses, shifting the higher-dose region of normal liver dose-volume histograms to lower doses. Furthermore, the population-based dose convolution tended to predict a higher risk of radiation damage to the liver (based on an in-house parameterization of the Lyman normal tissue complication probability model) than the individual patient calculations. For an individual plan, application of different individual random variations yielded change in effective volume differences with a 3% range. Plan adjustment to account for random setup variations generally resulted in a lower change in effective volume than initial planning using a planning target volume followed by calculation of delivered dose based on random offsets. CONCLUSION: This study hints at the factors that most strongly influence planning of liver treatments taking into account geometric variations. Given a setup verification methodology that rapidly reduces systematic offsets, the importance of realistic incorporation of geometric variations as an initial step in treatment planning, as well as possible plan refinement, is demonstrated.

Feasibility Studies↗

Retrospective analysis of prostate cancer patients with implanted gold markers using off-line and adaptive therapy protocols.

PURPOSE: To determine the efficacy of applying adaptive and off-line setup correction models to bony anatomy and gold fiducial markers implanted in the prostate, relative to daily alignment to skin tattoos and daily on-line corrections of the implanted gold markers. METHODS AND MATERIALS: Ten prostate cancer patients with implanted gold fiducial markers were treated using a daily on-line setup correction protocol. The patients' positions were aligned to skin tattoos and two orthogonal diagnostic digital radiographs were obtained before treatment each day. These radiographs were compared with digitally reconstructed radiographs to obtain the translational setup errors of the bony anatomy and gold markers. The adaptive, no-action-level and shrinking-action-level off-line protocols were retrospectively applied to the bony anatomy to determine the change in the setup errors of the gold markers. The protocols were also applied to the gold markers directly to determine the residual setup errors. RESULTS: The percentage of remaining fractions that the gold markers fell within the adaptive margins constructed with 1.5sigma' (estimated random variation) after 5, 10, and 15 measurement fractions was 74%, 88%, and 93% for the prone patients and 55%, 77%, and 93% for the supine patients, respectively. Using 2sigma', the percentage after 5, 10, and 15 measurements was 85%, 95%, and 97% for the prone patients and 68%, 87%, and 99% for the supine patients, respectively. The average initial three-dimensional (3D) setup error of the gold markers was 0.92 cm for the prone patients and 0.70 cm for the supine patients. Application of the no-action-level protocol to bony anatomy with N(m) = 3 days resulted in significant benefit to 4 of 10 patients, but 3 were significantly worse. The residual average 3D setup error of the gold markers was 1.14 cm and 0.51 cm for the prone and supine patients, respectively. When applied directly to the gold markers with N(m) = 3 days, 5 patients benefited and 3 were significantly worse. The residual 3D error of the gold markers was 1.14 cm and 0.76 cm for the prone and supine patients, respectively. Application of the shrinking-action-level protocol to bony anatomy with an initial action level of 1.0 cm and N(max) = 5 days decreased the residual systematic offset of the gold markers in 2 of 10 patients. The residual average 3D setup error of the gold markers was 1.2 cm and 1.0 cm for the prone and supine patients, respectively. When applied directly to the gold markers with N(max) = 5 days, the residual systematic offset of the gold markers decreased in 6 of 10 patients (0.84 cm and 0.67 cm for the prone and supine patients, respectively). In general, between 3 and 5 of the 10 patients showed significant decreases in setup errors with the application of these off-line protocols, and the remaining patients showed no significant improvement or showed significantly larger setup errors, as determined by the residual error of the gold markers. CONCLUSION: Changes in a prostate cancer patient's systematic and random setup characteristics during the course of therapy often violate the gaussian assumptions of adaptive and off-line correction models. Thus, off-line setup correction procedures, especially those directed at prostate localization using markers, will result in limited benefit to a minority of patients. The relative benefit of on-line localization is still potentially significant if the intrafraction motion is relatively small.

Gold↗

An application of Bayesian statistical methods to adaptive radiotherapy.

In adaptive radiotherapy, measured patient-specific setup variations are used to modify the patient setup and treatment plan, potentially many times during the treatment course. To estimate the setup adjustments and re-plan the treatment, the measured data are usually processed using Kalman filtering or by computing running averages. We propose, as an alternative, the use of Bayesian statistical methods, which combine a population (prior) distribution of systematic and random setup errors with the measurements to determine a patient-specific (posterior) probability distribution. The posterior distribution can either be used directly in the re-planning of the treatment or in the generation of statistics needed for adjustments. Based on the assumption that day-to-day setup variations are independent and identically distributed Normal distributions, we can efficiently compute parameters of the posterior distribution from parameters of the prior distribution and statistics of the measurements. We illustrate a simple procedure to apply the method in practice to adaptive radiotherapy, allowing for multiple adjustments of treatment parameters during the course of treatment.

Algorithms↗

Accuracy of a wireless localization system for radiotherapy.

PURPOSE: A system has been developed for patient positioning based on real-time localization of implanted electromagnetic transponders (beacons). This study demonstrated the accuracy of the system before clinical trials. METHODS AND MATERIALS: We describe the overall system. The localization component consists of beacons and a source array. A rigid phantom was constructed to place the beacons at known offsets from a localization array. Tests were performed at distances of 80 and 270 mm from the array and at positions in the array plane of up to 8 cm offset. Tests were performed in air and saline to assess the effect of tissue conductivity and with multiple transponders to evaluate crosstalk. Tracking was tested using a dynamic phantom creating a circular path at varying speeds. RESULTS: Submillimeter accuracy was maintained throughout all experiments. Precision was greater proximal to the source plane (sigmax = 0.006 mm, sigmay = 0.01 mm, sigmaz = 0.006 mm), but continued to be submillimeter at the end of the designed tracking range at 270 mm from the array (sigmax = 0.27 mm, sigmay = 0.36 mm, sigmaz = 0.48 mm). The introduction of saline and the use of multiple beacons did not affect accuracy. Submillimeter accuracy was maintained using the dynamic phantom at speeds of up to 3 cm/s. CONCLUSION: This system has demonstrated the accuracy needed for localization and monitoring of position during treatment.

Electrodes, Implanted↗

Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation.

Understanding the movement of tumors caused by respiratory motion is very important for conformal radiatherapy. However, respiratory motion is very difficult to study by conventional x-ray CT imaging since object motion causes inconsistent projection views, leading to artifacts in reconstructed images. We propose to estimate the parameters of a nonrigid, free breathing motion model from a set of projection views of the thorax that are acquired using a slowly rotating cone-beam CT scanner. This approach involves deforming a motion-free reference thorax volume according to the estimated parameters and comparing its projections to the corresponding measured projection views. The parameters are optimized by minimizing a regularized squared error cost function. Simulation results with a fan-beam geometry show good agreement between the estimated motion and the true motion, which supports the potential of this approach for estimating four-dimensional (three-dimensional spatial + temporal) respiratory motion.

Algorithms↗

Dose reconstruction in deforming lung anatomy: dose grid size effects and clinical implications.

In this study we investigated the accumulation of dose to a deforming anatomy (such as lung) based on voxel tracking and by using time weighting factors derived from a breathing probability distribution function (p.d.f.). A mutual information registration scheme (using thin-plate spline warping) provided a transformation that allows the tracking of points between exhale and inhale treatment planning datasets (and/or intermediate state scans). The dose distributions were computed at the same resolution on each dataset using the Dose Planning Method (DPM) Monte Carlo code. Two accumulation/interpolation approaches were assessed. The first maps exhale dose grid points onto the inhale scan, estimates the doses at the "tracked" locations by trilinear interpolation and scores the accumulated doses (via the p.d.f.) on the original exhale data set. In the second approach, the "volume" associated with each exhale dose grid point (exhale dose voxel) is first subdivided into octants, the center of each octant is mapped to locations on the inhale dose grid and doses are estimated by trilinear interpolation. The octant doses are then averaged to form the inhale voxel dose and scored at the original exhale dose grid point location. Differences between the interpolation schemes are voxel size and tissue density dependent, but in general appear primarily only in regions with steep dose gradients (e.g., penumbra). Their magnitude (small regions of few percent differences) is less than the alterations in dose due to positional and shape changes from breathing in the first place. Thus, for sufficiently small dose grid point spacing, and relative to organ motion and deformation, differences due solely to the interpolation are unlikely to result in clinically significant differences to volume-based evaluation metrics such as mean lung dose (MLD) and tumor equivalent uniform dose (gEUD). The overall effects of deformation vary among patients. They depend on the tumor location, field size, volume expansion, tissue heterogeneity, and direction of tumor displacement with respect to the beam, and are more likely to have an impact on serial organs (such as esophagus), rather than on large parallel organs (such as lung).

Body Burden↗

ASTRO's core physics curriculum for radiation oncology residents.

In 2002, the Radiation Physics Committee of the American Society of Therapeutic Radiology and Oncology (ASTRO) appointed an Ad-hoc Committee on Physics Teaching to Medical Residents. The main initiative of the committee was to develop a core curriculum for physics education. Prior publications that have analyzed physics teaching have pointed to wide discrepancies among teaching programs. The committee was composed of physicists or physicians from various residency program based institutions. Simultaneously, members had associations with the American Association of Physicists in Medicine (AAPM), ASTRO, Association of Residents in Radiation Oncology (ARRO), American Board of Radiology (ABR), and the American College of Radiology (ACR). The latter two organizations' representatives were on the physics examination committees, as one of the main agendas was to provide a feedback loop between the examining organizations and ASTRO. The document resulted in a recommended 54-h course. Some of the subjects were based on American College of Graduate Medical Education (ACGME) requirements (particles, hyperthermia), whereas the majority of the subjects along with the appropriated hours per subject were devised and agreed upon by the committee. For each subject there are learning objectives and for each hour there is a detailed outline of material to be covered. Some of the required subjects/h are being taught in most institutions (i.e., Radiation Measurement and Calibration for 4 h), whereas some may be new subjects (4 h of Imaging for Radiation Oncology). The curriculum was completed and approved by the ASTRO Board in late 2003 and is slated for dissemination to the community in 2004. It is our hope that teaching physicists will adopt the recommended curriculum for their classes, and simultaneously that the ABR for its written physics examination and the ACR for its training examination will use the recommended curriculum as the basis for subject matter and depth of understanding. To ensure that the subject matter and emphasis remain current and relevant, the curriculum will be updated every 2 years.

Curriculum↗

Evaluation of the influence of breathing on the movement and modeling of lung tumors.

PURPOSE: Respiration causes movement and potential shape change in lung tumors that are not fully appreciated using conventional free-breathing CT models for radiotherapy planning. Although target expansion has the potential to ensure proper tumor coverage in the face of motion on a free-breathing CT scan, large variations in how individual patients' tumors move may make such expansions difficult to uniformly define. In addition, excessive expansion may result in the unnecessary inclusion of normal lung in the treated volume. This study was designed to evaluate the influence of breathing movement on tumors and to assess the validity of the free-breathing CT scan for target delineation in the lung. METHODS AND MATERIALS: Data from 16 consecutive lung cancer patients who underwent treatment planning CT scans at inhale and exhale and during free breathing on a fast helical CT scanner were analyzed. Gross tumor volumes (GTV) were defined on each scan. A composite GTV was created by combining the inhale and exhale GTVs (COMP). Two methods of expansion were used to compare COMP to the free-breathing GTV (FREE). First the free-breathing data set was expanded uniformly by 1 cm (FREE + 1). Next, a nonuniform expansion was generated in all 6 directions to ensure complete coverage of COMP with the minimal subtended volume (FREE + EXP). The amount of excess normal lung treated with these 2 expansions was compared. The volume of the COMP missed using the 1-cm expansion was determined. RESULTS: There was a significant amount of excess normal lung tissue treated with the uniform 1-cm (FREE + 1) expansion, as well as with the nonuniform (FREE + EXP) expansion. In addition, there were also cases where this technique led to marginal miss of the tumor, including one case where 47% of the overall tumor was missed with this 1-cm (FREE + 1) expansion. An attempt to create a systematic model for expansion was not successful. Although the mean expansions in the anterior-posterior, superior-inferior, and right-left directions were reasonable (0.9, 1.0, and 0.8 cm, respectively), the large intrapatient variations (sigma 0.6 cm anterior-posterior, 0.7 cm superior-inferior, and 0.5 cm right-left) suggest difficulty in assigning a simple rule for population target expansion. Some extension of FREE outside of the borders of COMP was observed, suggesting the need for evaluation of reproducibility over multiple breathing states. CONCLUSIONS: Traditional methods of expanding the GTV to CTV by 1 cm are less than ideal. This method tends to include more normal lung than necessary and may lead to marginal miss. Interpatient tumor movement variations further prohibit defining a simple rule for nonuniform expansion that would minimize the volume of normal lung in the target. Although the development of target volumes by combining information from breath-hold CT scans at inhale and exhale states shows some promise in minimizing excess lung irradiated while maintaining adequate tumor coverage, further tests of breathing reproducibility need to be performed to provide a confident baseline for defining target expansions by this technique.

Adult↗

Interventions to reduce organ motion effects in radiation delivery.

Because organ motion during a radiation treatment fraction can be substantial, with resultant alterations in organ volume definition and dosimetry, interventions to reduce the impact of intratreatment organ motion are required for many patients if dose escalation and reduction of dose to normal tissue are treatment goals. Before radiation delivery, fluoroscopy, cine computed tomography scans and magnetic resonance imaging can be used to measure the magnitude of organ motion for an individual patient. Strategies to minimize organ motion caused by breathing during radiation include altering breathing patterns, treating during voluntary or controlled breath holds, gating the radiation beam or tracking it with organ motion. Here the first 2 interventions will be primarily discussed. Approaches to minimize nonrespiratory organ motion include maintaining the same preparative regimen before each treatment and ensuring comfortable immobilization and short overall treatment time.

Humans↗

Accounting for center-of-mass target motion using convolution methods in Monte Carlo-based dose calculations of the lung.

We have applied convolution methods to account for some of the effects of respiratory induced motion in clinical treatment planning of the lung. The 3-D displacement of the GTV center-of-mass (COM) as determined from breath-hold exhale and inhale CT scans was used to approximate the breathing induced motion. The time-course of the GTV-COM was estimated using a probability distribution function (PDF) previously derived from diaphragmatic motion [Med. Phys. 26, 715-720 (1990)] but also used by others for treatment planning in the lung [Int. J. Radiat. Oncol., Biol., Phys. 53, 822-834 (2002); Med. Phys. 30, 1086-1095 (2003)]. We have implemented fluence and dose convolution methods within a Monte Carlo based dose calculation system with the intent of comparing these approaches for planning in the lung. All treatment plans in this study have been calculated with Monte Carlo using the breath-hold exhale CT data sets. An analysis of treatment plans for 3 patients showed substantial differences (hot and cold spots consistently greater than +/- 15%) between the motion convolved and static treatment plans. As fluence convolution accounts for the spatial variance of the dose distribution in the presence of tissue inhomogeneities, the doses were approximately 5% greater than those calculated with dose convolution in the vicinity of the lung. DVH differences between the static, fluence and dose convolved distributions for the CTV were relatively small, however, larger differences were observed for the PTV. An investigation of the effect of the breathing PDF asymmetry on the motion convolved dose distributions showed that reducing the asymmetry resulted in increased hot and cold spots in the motion convolved distributions relative to the static cases. In particular, changing from an asymmetric breathing function to one that is symmetric results in an increase in the hot/cold spots of +/- 15% relative to the static plan. This increase is not unexpected considering that the target spends relatively more time at inhale as the asymmetry decreases (note that the treatment plans were generated using the exhale CT scans).

Body Burden↗

Mutual information based CT registration of the lung at exhale and inhale breathing states using thin-plate splines.

The advent of dynamic radiotherapy modeling and treatment techniques requires an infrastructure to weigh the merits of various interventions (breath holding, gating, tracking). The creation of treatment planning models that account for motion and deformation can allow the relative worth of such techniques to be evaluated. In order to develop a treatment planning model of a moving and deforming organ such as the lung, registration tools that account for deformation are required. We tested the accuracy of a mutual information based image registration tool using thin-plate splines driven by the selection of control points and iterative alignment according to a simplex algorithm. Eleven patients each had sequential CT scans at breath-held normal inhale and exhale states. The exhale right lung was segmented from CT and served as the reference model. For each patient, thirty control points were used to align the inhale CT right lung to the exhale CT right lung. Alignment accuracy (the standard deviation of the difference in the actual and predicted inhale position) was determined from locations of vascular and bronchial bifurcations, and found to be 1.7, 3.1, and 3.6 mm about the RL, AP, and IS directions. The alignment accuracy was significantly different from the amount of measured movement during breathing only in the AP and IS directions. The accuracy of alignment including thin-plate splines was more accurate than using affine transformations and the same iteration and scoring methodology. This technique shows promise for the future development of dynamic models of the lung for use in four-dimensional (4-D) treatment planning.

Algorithms↗

Alterations in normal liver doses due to organ motion.

PURPOSE: To assess the clinical significance of differences between treatment planning calculations based on static computed tomography (CT) and more realistic predictions of the actual delivered dose to intrahepatic lesions by a geometric convolution approach that accounts for random setup variations and breathing-induced organ motion. MATERIALS AND METHODS: We recalculated target and normal liver doses for 40 patients previously treated on a conformal therapy dose escalation protocol to include the effect of setup uncertainties and liver motion due to patient breathing. Initial three-dimensional (3D) dose calculations based on pretreatment CT scans taken with voluntary breath-hold at normal exhalation were convolved with 3D anisotropic probability distribution functions reflecting population measurements of position setup variation. The convolution also included a distribution function (one-dimensional, inferior-superior direction only) representing the asymmetric temporal pattern (biased toward exhalation, based on population measurements) of a typical breathing cycle, scaled in amplitude for each patient. RESULTS: After convolution, the minimum clinical target volume (CTV) dose met or exceeded the minimum planning target volume (PTV) dose from the static plan in all but one case, indicating adequate PTV design. However, clinically relevant and statistically significant increases (decreases) in liver normal tissue complication probability (NTCP) from values computed for the static cases occurred for tumors located toward the bottom (top) of the liver, as predicted for these patients scanned at exhalation. The change in liver NTCP (from a nominal 20%) ranged from +12.0% to -11.7% (average magnitude change 3.9% [sigma = 3.3%]). Changes in prescription dose required to restore the original 20% NTCP ranged from -3.7 Gy to +7.9 Gy (average magnitude change 1.9 Gy [sigma = 1.9 Gy]). CONCLUSIONS: Although the PTV concept can ensure adequate CTV coverage, the doses to normal liver are incorrectly modeled without including patient-related geometric uncertainties.

Algorithms↗