PubMed Health⌕ Search

Biomedical subjects

James Mechalakos

Publications and source records attributed to James Mechalakos.

6 recordsLinked to original sources

A comparison of intensity-modulated radiation therapy and concomitant boost radiotherapy in the setting of concurrent chemotherapy for locally advanced oropharyngeal carcinoma.

PURPOSE: The aim of this study was to compare toxicity/efficacy of conventional radiotherapy using delayed accelerated concomitant boost radiotherapy (CBRT) vs. intensity-modulated radiotherapy (IMRT) in the setting of concurrent chemotherapy (CT) for locally advanced oropharyngeal carcinoma. METHODS AND MATERIALS: Between September 1998 and June 2004, a total of 293 consecutive patients were treated at our institution for cancer of the oropharynx. Of these, 112 had Stage III/IV disease and squamous cell histology. In all, 41 were treated with IMRT/CT and 71 were treated with CBRT/CT, both to a median dose of 70 Gy. Most common CT was a planned two cycles given every 3 to 4 weeks of cisplatin, 100 mg/m2 i.v., but an additional cycle was given to IMRT patients when possible. Both groups were well-matched for all prognostic factors. RESULTS: Median follow-up was 46 months (range, 3-93 months) for the CBRT patients and 31 months (range, 20-64 months) for the IMRT group. Three-year actuarial local-progression-free, regional-progression-free, locoregional progression-free, distant-metastases-free, disease-free, and overall survival rates were 85% vs. 95% (p = 0.17), 95% vs. 94% (p = 0.90), 82% vs. 92% (p = 0.18), 85% vs. 86% (p = 0.78), 76% vs. 82% (p = 0.57), and 81% vs. 91% (p = 0.10) for CBRT and IMRT patients, respectively. Three patients died of treatment-related toxicity in the CBRT group vs. none undergoing IMRT. At 2 years, 4% IMRT patients vs. 21% CBRT patients were dependent on percutaneous endoscopic gastrostomy (p = 0.02). Among those who had > or =20 months follow-up, there was a significant difference in Grade > or =2 xerostomia as defined by the criteria of the Radiation Therapy and Oncology Group, 67% vs. 12% (p = 0.02), in the CBRT vs. IMRT arm. CONCLUSION: In the setting of CT for locally advanced oropharyngeal carcinoma, IMRT results in lower toxicity and similar treatment outcomes when compared with CBRT.

Adult↗

Results of a one year survey of output for linear accelerators using IMRT and non-IMRT techniques.

This paper presents the results of a one year survey of treated fields for 3 treatment machines at our New Jersey regional center. One machine predominantly treated IMRT prostate patients using a sliding window technique. The others were not equipped to deliver IMRT. Information obtained for each treated field included patient number, modality, monitor units delivered, gantry angle, and time. Data was obtained directly from our record and verify system and analyzed using a spreadsheet. We studied workload (MU/week), patient load, and average MU per patient as a function of time, as well as angular distributions and number of treatment fractions per patient. We also calculated the fraction of time the beam was on during treatments. By the end of the survey year, the workload of the IMRT machine reached approximately 100,000 MU/week and that of the non-IMRT machines was approximately 40-45000 MU/week. This was due predominantly to the higher number of monitor units for IMRT plans. Patient loads were not significantly different for the 3 machines. Duty cycle was 14% and 16% for the non-IMRT machines and 27% for the IMRT machine. The difference in workload for IMRT treatments relative to non-IMRT treatments confirms an earlier study performed at our institution using a much smaller data sample. One needs to consider the increase in leakage associated with this higher workload when designing shielding for an IMRT room.

Data Collection↗

Dosimetric effect of respiratory motion in external beam radiotherapy of the lung.

BACKGROUND AND PURPOSE: To study the effect of breathing motion on gross tumor volume (GTV) coverage for lung tumors using dose-volume histograms and relevant dosimetric indices. PATIENTS AND METHODS: Treatment plans were chosen for 12 patients treated at our institution for lung carcinoma. GTV volumes of these patients ranged from 1.2 to 97.3 cm(3). A margin of 1-2 cm was used to generate the planning target volume (PTV). Additional margins of 0.6-1.0 cm were added to the PTV when designing treatment portals. For the purposes of TCP calculation, the prescription dose was assumed to be 70 Gy to remove the effects of prescription differences. Setup error was incorporated into the evaluation of treatment plans with a systematic component of sigma(RL) = 0.2 cm, sigma(AP) = 0.2 cm, and sigma(SI) = 0.3 cm and a random component of sigma(RL) = 0.3 cm, sigma(AP) = 0.3 cm, and sigma(SI) = 0.3 cm. Breathing motion was incorporated into these plans based on an independent analysis of fluoroscopic movies of the diaphragm for 7 patients. The systematic component of breathing motion (sigma(RL) = 0.3 cm, sigma(AP) = 0.2 cm, and sigma(SI) = 0.6 cm) was incorporated into the treatment plans on a slice by slice basis. The intrafractional component of breathing motion (sigma(RL) = 0.3 cm, sigma(AP) = 0.2 cm, and sigma(SI) = 0.6 cm) was incorporated by averaging the dose calculation over all displacements of the breathing cycle. Each patient was simulated 500 times to discern the range of possible outcomes. The simulations were repeated for a worst case scenario which used only breathing data with a large diaphragmatic excursion, both with and without intrafractional breathing motion. RESULTS: Dose to 95% of the GTV (D95), volume of the GTV receiving 95% of the prescription dose (V95) and TCP changed an average of -1.4+/-4.2, -1.0+/-3.3, and -1.4+/-3.8%, respectively, with the incorporation of normal breathing effects. In the worst case scenario (heavy breathers), D95 and V95 changed an average of -9.8+/-10.1 and -8.3+/-11.3%, respectively, and TCP changed by -8.1+/-9.1%. GTVs with volumes greater than 60 cm(3) showed stronger sensitivity to breathing especially if the shape was non-ellipsoidal. In the normal breathing case, the probability of a decrease in D95, V95, or TCP of a magnitude greater than 10% is less than 4%, and in the worse case scenario this probability is approximately 30-40% with intrafractional breathing motion included, and less than 10% with intrafractional breathing motion not included. CONCLUSIONS: With the PTV margins routinely used at our center, the effects of normal breathing on coverage are small on the average, with a less than 4% chance of a 10% or greater decrease in D95, V95, or TCP. However, in patients with large respiration-induced motion, the effect can be significant and efforts to identify such patients are important.

Artifacts↗

Development of a semi-automatic alignment tool for accelerated localization of the prostate.

PURPOSE: Delivering high dose to prostate with external beam radiation has been shown to improve local tumor control. However, it has to be carefully performed to avoid partial target miss and delivering excessive dose to surrounding normal tissues. One way to achieve safe dose escalation is to precisely localize prostate immediately before daily treatment. Therefore, the radiation can be accurately delivered to the target. Once the prostate position is determined with high confidence, planning target volume (PTV) safety margin might be reduced for further reduction of rectal toxicity. A rapid computed tomography (CT)-based online prostate localization method is presented for this purpose. METHODS AND MATERIALS: Immediately before each treatment session, the patient is immobilized and undergoes a CT scan in the treatment position using a CT scanner situated in the treatment room. At the CT console, posterior, anterior, left, and right extents of the prostate are manually identified on each axial slice. The translational prostate displacements relative to the planned position are estimated by simultaneously fitting these identified extents from this CT scan to a template created from the finely sliced planning CT scan. A total of 106 serial CT scans from 8 prostate cancer patients were performed immediately before treatments and used to retrospectively evaluate the precision of this daily prostate targeting method. The three-dimensional displacement of the prostate with respect to its planned position was estimated. RESULTS: Five axial slices from each treatment CT scan were sufficient to produce a reliable correction when compared with prostate center of gravity (CoG) displacements calculated from physician-drawn contours. The differences (mean +/- SD) between these two correction schemes in the right-left (R/L), posterior-anterior (P/A), and superior-inferior (S/I) directions are 0.0 +/- 0.4 mm, 0.0 +/- 0.7 mm, and -0.4 +/- 1.9 mm, respectively. With daily CT extent-fitting correction, 97% of the scans showed that the entire posterior prostate gland was covered by PTV given a margin of 6 mm at the rectum-prostate interface and 10 mm elsewhere. In comparison, only 74% and 65% could be achieved by the corrections based on daily and weekly bony matching on portal images, respectively. CONCLUSIONS: Results show that daily CT extent fitting provides a precise correction of prostate position in terms of CoG. Identifying prostate extents on five axial CT slices at the CT console is less time-consuming compared with daily contouring of the prostate on many slices. Taking advantage of the prostate curvature in the longitudinal direction, this method also eliminates the necessity of identifying prostate base and apex. Therefore, it is clinically feasible and should provide an accelerated localization of the prostate immediately before daily treatment.

Feasibility Studies↗

Estimation of shielding factors for linear accelerators.

There have been a number of persons who have estimated that the use of multi-leaf collimation and IMRT techniques increase the workload in treatment rooms to the extent that assumptions used in shielding calculations should reflect these increased workloads. This paper examines the workloads in a large department with treatment machines of varying energies and techniques. While the sample size examined is limited, the data presented demonstrate that the standard assumptions may still be sufficiently conservative that no substantive changes may be needed.

Humans↗