PubMed Health⌕ Search

Biomedical subjects

James R Brookeman

Publications and source records attributed to James R Brookeman.

11 recordsLinked to original sources

Evaluation of the reproducibility of lung motion probability distribution function (PDF) using dynamic MRI.

Treatment planning based on probability distribution function (PDF) of patient geometries has been shown a potential off-line strategy to incorporate organ motion, but the application of such approach highly depends upon the reproducibility of the PDF. In this paper, we investigated the dependences of the PDF reproducibility on the imaging acquisition parameters, specifically the scan time and the frame rate. Three healthy subjects underwent a continuous 5 min magnetic resonance (MR) scan in the sagittal plane with a frame rate of approximately 10 f s-1, and the experiments were repeated with an interval of 2 to 3 weeks. A total of nine pulmonary vessels from different lung regions (upper, middle and lower) were tracked and the dependences of their displacement PDF reproducibility were evaluated as a function of scan time and frame rate. As results, the PDF reproducibility error decreased with prolonged scans and appeared to approach equilibrium state in subjects 2 and 3 within the 5 min scan. The PDF accuracy increased in the power function with the increase of frame rate; however, the PDF reproducibility showed less sensitivity to frame rate presumably due to the randomness of breathing which dominates the effects. As the key component of the PDF-based treatment planning, the reproducibility of the PDF affects the dosimetric accuracy substantially. This study provides a reference for acquiring MR-based PDF of structures in the lung.

Artifacts↗

Evaluation of emphysema severity and progression in a rabbit model: comparison of hyperpolarized 3He and 129Xe diffusion MRI with lung morphometry.

The apparent diffusion coefficients (ADCs) of hyperpolarized (3)He and (129)Xe gases were measured in the lungs of rabbits with elastase-induced emphysema and correlated against the mean chord length from lung histology. In vivo measurements were performed at baseline and 2, 4, 6, and 8 wk after instillation of elastase (mild and moderate emphysema groups) or saline (control group). ADCs were determined from acquisitions that used two b values. To investigate the effect of b value on the results, b-value pairs of 0 and 1.6 s/cm(2) and 0 and 4.0 s/cm(2) were used for (3)He, and b-value pairs of 0 and 5.0 s/cm(2) and 0 and 10.0 s/cm(2) were used for (129)Xe. At 8 wk after instillation, the rabbits were euthanized, and the lungs were analyzed histologically and morphometrically. ADCs for the rabbits in the control group did not change significantly from baseline to week 8, whereas ADCs for the rabbits in the emphysema groups increased significantly (P < 0.05) for all gas and b-value combinations except (129)Xe with the b-value pair of 0 and 5.0 s/cm(2). The largest percent change in mean ADC from baseline to week 8 (15.3%) occurred with (3)He and the b-value pair of 0 and 1.6 s/cm(2) for rabbits in the moderate emphysema group. ADCs (all b values) were strongly correlated (r = 0.62-0.80, P < 0.001) with mean chord lengths from histology. These results further support the ability of diffusion-weighted MRI with hyperpolarized gases to detect regional and global structural changes of emphysema within the lung.

Animals↗

Assessment of lung development using hyperpolarized helium-3 diffusion MR imaging.

PURPOSE: To determine whether hyperpolarized helium-3 (HHe) diffusion MR can detect the expected enlargement of alveoli that occurs with lung growth during childhood. MATERIALS AND METHODS: A total of 29 normal subjects aged four to 30 years underwent HHe diffusion MR imaging with the b-value pair 0, 1.6 second/cm(2). A second acquisition during a separate breathhold was performed using the b-value pair 0, 4 second/cm(2) to evaluate the dependence on b-value. The mean apparent diffusion coefficient (ADC) and lung volume for each acquisition and each subject was determined. RESULTS: Subjects as young as four years of age were able to cooperate with the imaging procedure. The mean ADC increased with increasing subject age (r = 0.8; P < 0.001), with a 55% increase in mean ADC from the youngest to oldest subject. Lung volumes measured on MR were highly repeatable for the two HHe MR acquisitions (r = 0.980, P < 0.001). The mean ADC values measured with the two different b-value pairs were highly correlated (r = 0.975; P < 0.001), but the higher b-value pair resulted in slightly lower mean ADCs (P < 0.001). CONCLUSION: HHe diffusion MR appears to detect the expected increase in alveolar size during childhood, and thus HHe MR may be a noninvasive method to assess development of the lung microstructure.

Adolescent↗

Hyperpolarized 3He lung imaging at 0.5 and 1.5 Tesla: a study of susceptibility-induced effects.

Hyperpolarized (3)He MRI of the human lung was performed at 0.54 and 1.5 T using identical software and hardware (except for RF coils) at both field strengths. The T(*) (2) of (3)He gas in the lung was measured, and the effects of magnetic-susceptibility-induced field inhomogeneities on the appearance of interleaved-spiral and interleaved-echo-planar lung images at 1.5 T were compared to those at 0.54 T. Mean T(*) (2) values for (3)He gas in the healthy human lung were 26.8 +/- 1.5 ms and 67.9 +/- 1.3 ms at 1.5 and 0.54 T, respectively. At 0.54 T, interleaved-spiral images showed markedly less blurring due to susceptibility effects compared to images acquired at 1.5 T. At both 0.54 and 1.5 T, interleaved-echo-planar images appeared essentially identical to corresponding GRE images, even though the data-sampling period per echo and echo time were substantially longer for the interleaved-echo-planar images acquired at 0.54 T.

Echo-Planar Imaging↗

Hyperpolarized HHe 3 MRI of the lung in cystic fibrosis: assessment at baseline and after bronchodilator and airway clearance treatment.

RATIONALE AND OBJECTIVES: The purpose of this study is to determine hyperpolarized helium 3 (HHe) magnetic resonance (MR) findings of the lung in patients with cystic fibrosis (CF) compared with healthy subjects and determine whether HHe MR can detect changes after bronchodilator therapy or mechanical airway mucus clearance treatment. MATERIALS AND METHODS: Thirty-one subjects, 16 healthy volunteers and 15 patients with CF, underwent HHe lung ventilation MR imaging and spirometry at baseline. Eight patients with CF then were treated with nebulized albuterol, after which a follow-up HHe MR scan was obtained. Subsequently, recombinant human deoxyribonuclease (DNase) treatment and chest physical therapy were performed in these eight subjects, followed by a third HHe MR scan. For each MR study, the number of ventilation defects was scored by a human reader. RESULTS: Patients with CF had significantly more HHe MR ventilation defects per image than healthy subjects (mean, 8.2 defects in patients with CF vs 1.6 defects in healthy subjects; P < .05). Even the four subjects with CF with a normal forced expiratory volume in 1 second had significantly more ventilation defects than healthy subjects (mean, 6.5 defects in these patients with CF; P = .0002). After treatment with albuterol, there was a small, but statistically significant, decrease in number of ventilation defects (mean, 9.6-8.0 defects; P = .025). After DNase and chest physical therapy, there was a trend toward increasing ventilation defects (mean, 8.3 defects; P = .096), but with a residual net improvement relative to baseline. CONCLUSION: In patients with CF, HHe MR ventilation defects correlate with spirometry, change with treatment, and are elevated in number in patients with CF with normal spirometry results. Thus, HHe MR appears to possess many of the characteristics required of a biomarker for pulmonary CF and may be useful in the evaluation of CF pulmonary disease severity or progression.

Administration, Inhalation↗

Pulmonary embolism: comprehensive evaluation with MR ventilation and perfusion scanning with hyperpolarized helium-3, arterial spin tagging, and contrast-enhanced MRA.

PURPOSE: Development of a comprehensive magnetic resonance (MR) examination consisting of MR angiography (MRA) and MR ventilation and perfusion (MR V/Q) scan for the detection of pulmonary emboli (PE) and assessment of the technique in a rabbit model. MATERIALS AND METHODS: Reversible PE was induced by inflating a non-detachable silicon balloon in the left pulmonary artery of five New Zealand White rabbits. MR V/Q scans were obtained prior to, during, and after balloon deflation. MRA was performed during balloon inflation. MR ventilation imaging was performed after the inhalation of hyperpolarized helium-3. MR perfusion imaging was performed with Flow-sensitive Alternating Inversion Recovery with an Extra Radiofrequency pulse technique (FAIRER). High-resolution contrast-enhanced MR pulmonary angiography was used to confirm the occlusion of the pulmonary artery. All imaging was performed on a 1.5-T whole body scanner with broadband capabilities. RESULTS: High-resolution ventilation images of the lungs were obtained. No ventilation defects were detected before, during, or after resolution of simulated PE. FAIRER imaging allowed visualization of pulmonary perfusion. No perfusion defects were detected prior to balloon inflation. During balloon inflation (PE), there was decreased perfusion in the left lower lobe. After reversal of the PE, there was improved perfusion to the left lower lobe. In analogy to nuclear medicine techniques, acute PE produced a mismatched defect in the MR V/Q scan. MRA verified the occlusive filling defect in the left pulmonary artery. CONCLUSION: High-resolution MRA and MR V/Q imaging of the lung is feasible and allows comprehensive assessment of pulmonary embolism in one imaging session.

Animals↗

Exploring lung function with hyperpolarized (129)Xe nuclear magnetic resonance.

With the use of polarization-transfer pulse sequences and hyperpolarized (129)Xe NMR, gas exchange in the lung can be measured quantitatively. However, harnessing the inherently high sensitivity of this technique as a tool for exploring lung function requires a fundamental understanding of the xenon gas-exchange and diffusion processes in the lung, and how these may differ between healthy and pathological conditions. Toward this goal, we employed NMR spectroscopy and imaging techniques in animal models to investigate the dependence of the relative xenon gas exchange rate on the inflation level of the lung and the tissue density. The spectroscopic results indicate that gas exchange occurs on a time scale of milliseconds, with an average effective diffusion constant of about 3.3 x 10(-6)cm(2)/s in the lung parenchyma. Polarization-transfer imaging pulse sequences, which were optimized based on the spectroscopic results, detected regionally increased gas-exchange rates in the lung, indicative of increased tissue density secondary to gravitational compression. By exploiting the gas-exchange process in the lung to encode physiologic parameters, these methods may be extended to noninvasive regional assessments of lung-tissue density and the alveolar surface-to-volume ratio, and allow lung pathology to be detected at an earlier stage than is currently possible.

Algorithms↗

Rapid hyperpolarized 3He diffusion MRI of healthy and emphysematous human lungs using an optimized interleaved-spiral pulse sequence.

PURPOSE: To develop and validate an interleaved-spiral diffusion pulse sequence capable of hyperpolarized (3)He MR imaging of the whole lung in less than 10 seconds. MATERIALS AND METHODS: Hyperpolarized (3)He diffusion measurements were performed in seven healthy volunteers and five patients with emphysema using an interleaved-spiral pulse sequence that provided 11 contiguous 15-mm thick coronal ADC maps, with an in-plane resolution of 3.9 mm, covering the whole lung in 5.5 seconds. The resulting means and SDs of ADC values were compared statistically to those from a gradient-echo pulse sequence with identical resolution and diffusion-weighting gradients that acquired five ADC maps in 10.5 seconds. RESULTS: High-quality diffusion-weighted interleaved-spiral images covering the whole lung were obtained, and showed no significant susceptibility-induced image degradation compared to corresponding gradient-echo images. On a subject-by-subject basis, the means and SDs of ADC values for the interleaved-spiral technique were not statistically different from those for the gradient-echo technique. The mean ADC values from the two techniques were highly correlated on a section-by-section basis (R = 0.99). CONCLUSION: The interleaved-spiral diffusion pulse sequence permits rapid acquisition of contiguous ADC maps covering the whole lung during a short breath-hold period, and provides ADC values that are statistically equivalent to those from standard gradient-echo techniques.

Adult↗

Imaging the lungs in asthmatic patients by using hyperpolarized helium-3 magnetic resonance: assessment of response to methacholine and exercise challenge.

BACKGROUND: Imaging of gas distribution in the lungs of patients with asthma has been restricted because of the lack of a suitable gaseous contrast agent. Hyperpolarized helium-3 (HHe3) provides a new technique for magnetic resonance imaging of lung diseases. OBJECTIVE: We sought to investigate the use of HHe3 gas to image the lungs of patients with moderate or severe asthma and to assess changes in gas distribution after methacholine and exercise challenge. METHODS: Magnetic resonance imaging was performed in asthmatic patients immediately after inhalation of HHe3 gas. In addition, images were obtained before and after methacholine challenge and a standard exercise test. RESULTS: Areas of the lung with no signal or sharply reduced HHe3 signal (ventilation defects) are common in patients with asthma, and the number of defects was inversely related to the percent predicted FEV(1) (r = 0.71, P <.002). After methacholine challenge (n = 3), the number of defects increased. Similarly, imaging of the lungs after exercise (n = 6) showed increased ventilation defects in parallel with decreases in FEV(1). The increase in defects after challenge in these 9 asthmatic patients was significant both for the number (P <.02) and extent (P <.02) of the defects. The variability and speed of changes in ventilation and the complete lack of signal in many areas is in keeping with a model in which the defects result from airway closure. CONCLUSION: HHe3 magnetic resonance provides a new technique for imaging the distribution of inhaled air in the lungs. The technique is suitable for following responses to treatment of asthma and changes after methacholine or exercise challenge.

Adolescent↗

Merging parametric active contours within homogeneous image regions for MRI-based lung segmentation.

Inhaled hyperpolarized helium-3 (3He) gas is a new magnetic resonance (MR) contrast agent that is being used to study lung functionality. To evaluate the total lung ventilation from the hyperpolarized 3He MR images, it is necessary to segment the lung cavities. This is difficult to accomplish using only the hyperpolarized 3He MR images, so traditional proton (1H) MR images are frequently obtained concurrent with the hyperpolarized 3He MR examination. Segmentation of the lung cavities from traditional proton (1H) MRI is a necessary first step in the analysis of hyperpolarized 3He MR images. In this paper, we develop an active contour model that provides a smooth boundary and accurately captures the high curvature features of the lung cavities from the 1H MR images. This segmentation method is the first parametric active contour model that facilitates straightforward merging of multiple contours. The proposed method of merging computes an external force field that is based on the solution of partial differential equations with boundary condition defined by the initial positions of the evolving contours. A theoretical connection with fluid flow in porous media and the proposed force field is established. Then by using the properties of fluid flow we prove that the proposed method indeed achieves merging and the contours stop at the object boundary as well. Experimental results involving merging in synthetic images are provided. The segmentation technique has been employed in lung 1H MR imaging for segmenting the total lung air space. This technology plays a key role in computing the functional air space from MR images that use hyperpolarized 3He gas as a contrast agent.

Administration, Inhalation↗

Emphysema: hyperpolarized helium 3 diffusion MR imaging of the lungs compared with spirometric indexes--initial experience.

PURPOSE: To quantitatively evaluate hyperpolarized helium 3 ((3)He) diffusion magnetic resonance (MR) images of the lung in patients with emphysema and to determine whether apparent diffusion coefficients (ADCs) measured with MR imaging correlate with spirometric indexes. MATERIALS AND METHODS: Hyperpolarized (3)He diffusion MR imaging was performed in 16 healthy volunteers and 11 patients. Coronal diffusion-sensitized MR images were obtained during suspended respiration after inhalation of laser-polarized (3)He gas, and images of the ADC were calculated. Spirometry was performed immediately before imaging. The mean and SD of the ADCs were compared between subject groups and were correlated with spirometric indexes. RESULTS: ADC images were homogeneous in volunteers, but demonstrated regional variations in patients. The mean and SD of the ADCs for patients were significantly larger (P <.002) than those for volunteers. The mean ADCs for all subjects correlated with the percentage of predicted forced expiratory volume in 1 second, or FEV(1), (r = -0.797, P <.001) and the ratio of FEV(1) to forced vital capacity, or FVC, (r = -0.930, P <.001). ADC images in patients demonstrated a significant increase (P <.001) in the ADCs in the upper regions compared with the lower regions of the lung. CONCLUSION: Hyperpolarized (3)He diffusion MR imaging demonstrated potential for use in evaluating the global and regional severity of emphysema.

Adult↗