PubMed Health⌕ Search

Biomedical subjects

James R Prudent

Publications and source records attributed to James R Prudent.

10 recordsLinked to original sources

MultiCode-RTx real-time PCR system for detection of subpopulations of K65R human immunodeficiency virus type 1 reverse transcriptase mutant viruses in clinical samples.

We report a real-time PCR assay capable of detecting drug-resistant human immunodeficiency virus type 1 reverse transcriptase K65R mutant virus at a level of 0.5% in polymorphic patient plasma specimens. Fifty-three treatment-naïve and 20 treatment-experienced specimens were successfully genotyped with the new method. Results were in agreement with population sequencing and the labor-intensive single-genome sequencing method.

Base Sequence↗

A continuous assay for DNA cleavage using molecular break lights.

Exploring the properties of molecules that cleave DNA (i.e., enzymatic nucleases, chemical footprinting agents, and naturally occurring DNA cleaving antibiotics) has been an ongoing process with benefits extending toward both laboratory and clinical applications. Despite the progress that has been made toward understanding the mechanics of DNA cleavage, a simple and continuous assay for detecting DNA cleavage has been lacking. Herein, we describe the molecular break light assay, wherein a single oligo-nucleotide modified by a 5'-fluorophore-3'-quencher pair adopting a stem-loop structure with an appropriate DNA recognition site, provides for the rapid assaying of DNA cleavage with high sensitivity. Furthermore, the described methodology is highly convenient in that it is readily adaptable to common laboratory fluorometers and multi-well plate/ array systems, which may provide the basis for high-throughput screening of novel DNA cleaving agents. This assay may also be further extended to natural or "unnatural" transcription factor protection assay systems.

DNA↗

Using expanded genetic alphabets to simplify high-throughput genetic testing.

DNA is the only chemistry that allows for molecular recognition on demand. Unlike any other molecular recognition chemistry, DNA enables the simple design and rapid synthesis of molecule sets that will recognize each other and self-assemble into nanostructures. In molecular diagnostics, DNA is used to capture complementary sequences in order to decode complex mixes. Expanding DNA chemistry to include additional base pairs enables a more precise manipulation of nanostructures constructed with DNA. MultiCode technology is that type of expanded DNA chemistry. The technology exploits DNA hydrogen bonding patterns that differ from natural DNA, thereby enabling a simple means of transcending problems that are otherwise unsolvable. Made up of additional base pairs (not simply single bases), MultiCode technology is used today to decode sequences in an orthogonal manner to natural DNA. This review will discuss MultiCode technology and specifically focus on how the technology can be used to build molecular testing platforms.

CpG Islands↗

Multiplexed detection of anthrax-related toxin genes.

Simultaneous analysis of three targets in three colors on any real-time polymerase chain reaction (PCR) instrument would increase the flexibility of real-time PCR. For the detection of Bacillus strains that can cause inhalation anthrax-related illness, this ability would be valuable because two plasmids confer virulence, and internal positive controls are needed to monitor the testing in cases lacking target-specific signals. Using a real-time PCR platform called MultiCode-RTx, multiple assays were developed that specifically monitor the presence of Bacillus anthracis-specific virulence plasmid-associated genes. In particular for use on LightCycler-1, two triplex RTx systems demonstrated high sensitivity with limits of detection nearing single-copy levels for both plasmids. Specificity was established using a combination of Ct values and correct amplicon melting temperatures. All reactions were further verified by detection of an internal positive control. For these two triplex RTx assays, the analytical detection limit was one to nine plasmid copy equivalents, 100% analytical specificity with a 95% confidence interval (CI) of 9%, and 100% analytical sensitivity with a CI of 2%. Although further testing using clinical or environmental samples will be required to assess diagnostic sensitivity and specificity, the RTx platform achieves similar results to those of probe-based real-time systems.

Antigens, Bacterial↗

Quantifying mixed populations of drug-resistant human immunodeficiency virus type 1.

In order to survive prolonged treatment with antiretroviral nucleoside analogs, the human immunodeficiency virus type 1 (HIV-1) is selectively forced to acquire mutations in the reverse transcriptase (RT) gene. Some of these mutations are more common than others and have become markers for antiretroviral resistance. For the early detection of these markers, a novel MultiCode-RTx one-step testing system to rapidly and simultaneously characterize mixtures of HIV-1 targets was designed. For cDNA, nucleotide polymorphisms for codon M184V (ATG to GTG) and K65R (AAA to AGA) could be differentiated and quantified even when the population mixture varied as much as 1 to 10,000. Standard mixed-population curves using 1 to 100% of the mutant or wild type generated over 4 logs of total viral particle input did not affect the overall curves, making the method robust. The system was also applied to a small set of samples extracted from infected individuals on nucleoside reverse transcriptase inhibitor therapy. Of 13 samples tested, all were positive for HIV and 10 of the 13 genotypes determined were concordant with the line probe assay. MultiCode-RTx could be applied to other drug-selected mutations in the viral genome or for applications where single-base changes in DNA or RNA occur at frequencies reaching 0.01% to 1%, respectively.

Anti-HIV Agents↗

Multiplexed genetic analysis using an expanded genetic alphabet.

BACKGROUND: All states require some kind of testing for newborns, but the policies are far from standardized. In some states, newborn screening may include genetic tests for a wide range of targets, but the costs and complexities of the newer genetic tests inhibit expansion of newborn screening. We describe the development and technical evaluation of a multiplex platform that may foster increased newborn genetic screening. METHODS: MultiCode PLx involves three major steps: PCR, target-specific extension, and liquid chip decoding. Each step is performed in the same reaction vessel, and the test is completed in approximately 3 h. For site-specific labeling and room-temperature decoding, we use an additional base pair constructed from isoguanosine and isocytidine. We used the method to test for mutations within the cystic fibrosis transmembrane conductance regulator (CFTR) gene. The developed test was performed manually and by automated liquid handling. Initially, 225 samples with a range of genotypes were tested retrospectively with the method. A prospective study used samples from >400 newborns. RESULTS: In the retrospective study, 99.1% of samples were correctly genotyped with no incorrect calls made. In the perspective study, 95% of the samples were correctly genotyped for all targets, and there were no incorrect calls. CONCLUSIONS: The unique genetic multiplexing platform was successfully able to test for 31 targets within the CFTR gene and provides accurate genotype assignments in a clinical setting.

Autoanalysis↗

Nucleic acid analysis using an expanded genetic alphabet to quench fluorescence.

Organic chemistry has made possible the synthesis of molecules that expand on Nature's genetic alphabet. Using the previously described nonstandard DNA base pair constructed from isoguanine and 5-methylisocytosine, we report a highly specific and sensitive method that allows for the fast and specific quantitation of genetic sequences in a closed tube format. During PCR amplification, enzymatic site-specific incorporation of a quencher covalently linked to isoguanine allows for the simultaneous detection and identification of multiple targets. The specificity of method is then established by analysis of thermal denaturation or melting of the amplicons. The appropriate functions of all reactions are further verified by incorporation of an independent target into the reaction mixture. We report that the method is sensitive down to the single copy level, and specificity is demonstrated by multiplexed end-point genotypic analysis of four targets simultaneously using four separate fluorescent reporters. The method is general enough for quantitative and qualitative analysis of both RNA and DNA using previously developed primer sets. Though the method described employs the commonly used PCR, the enzymatic incorporation of reporter groups into DNA site-specifically should find broad utility throughout molecular biology.

Adenosine↗

A third base pair for the polymerase chain reaction: inserting isoC and isoG.

Two additional bases (isoguanosine and isocytosine), generating a third base pair, have been implemented in PCR. Enzyme fidelity for the third base pair is demonstrated using molecular thermodynamic melting, chemical cleavage and molecular beacons. When amplifying as few as 15 targets containing multiple non-natural base pairs with 40 cycles of amplification, our results confirm sequence conservation. The additional sequence space provided by three base pairs allows for the construction of molecular tools that achieve higher complexity and better discrimination than those possible with natural DNA alone.

Adenosine↗

Enzymatic repair of an expanded genetic information system.

The excision repair machinery of a thermophilic bacterium has been shown to recognize and repair an expanded genetic base pair. Native Thermus aquaticus DNA polymerase will remove a mispaired natural base and replace it with a non-natural base to form an expanded base pair. In addition, DNA ligase will recognize a nick formed by polymerase between two non-natural base pairs and covalently attach the two strands, thus demonstrating complete repair of a bifurcated base-paired model duplex. These results add evidence to the idea that the cellular replication and repair machinery of an organism containing an expanded genetic alphabet could recognize and properly repair a site containing consecutive unnatural bases.

Base Pair Mismatch↗

Exploiting the enzymatic recognition of an unnatural base pair to develop a universal genetic analysis system.

BACKGROUND: With the invention of the DNA chip, genome-wide analysis is now a reality. Unfortunately, solid-phase detection systems such as the DNA chip suffer from a narrow range in quantification and sensitivity. Today the best methodology for sensitive, wide dynamic range quantification and genotyping of nucleic acids is real-time PCR. However, multiplexed real-time PCR technologies require complicated and costly design and manufacturing of separate detection probes for each new target. METHODS: We developed a novel real-time PCR technology that uses universal energy transfer probes constructed from An Expanded Genetic Information System (AEGIS) for both quantification and genotyping analyses. RESULTS: RNA quantification by reverse transcription-PCR was linear over four orders of magnitude for the simultaneous analysis of beta-actin messenger RNA and 18S ribosomal RNA. A single trial validation study of 176 previously genotyped clinical specimens was performed by endpoint analysis for factor V Leiden and prothrombin 20210A mutation detection. There was concordance for 173 samples between the genotyping results from Invader tests and the AEGIS universal energy transfer probe system for both factor V Leiden and prothrombin G20210A. Two prothrombin and one factor V sample gave indeterminate results (no calls). CONCLUSION: The AEGIS universal probe system allows for rapid development of PCR assays for nucleic acid quantification and genotyping.

Actins↗