PubMed Health⌕ Search

Biomedical subjects

Jamie B Conti

Publications and source records attributed to Jamie B Conti.

At least 19 recordsLinked to original sources

Cardiac resynchronization therapy for treatment of heart failure in the elderly.

Congestive heart failure affects 5 million patients each year and is more common in elderly patients. Cardiac resynchronization therapy (CRT) or biventricular pacing is the simultaneous pacing of both ventricles, an approach that can improve symptoms and survival in some heart failure (HF) patients. Although no randomized controlled trial has evaluated CRT specifically in elderly patients,many of the patients included in the landmark CRT trials were aged 70 and older. Data suggest that CRT is a safe and efficacious treatment of HF in geriatric patients.

Aged↗

Psychological aspects of cardiac devices and recalls in patients with implantable cardioverter defibrillators.

The product recall of an implantable cardioverter defibrillator (ICD) creates a potentially stressful event for patients. This study briefly describes the psychological adjustment of patients with implantable devices and makes recommendations for the management of device recalls and adverse outcomes to minimize psychological distress. Because the occurrence of ICD-specific fears and symptoms of anxiety are the most common psychological symptoms experienced by ICD recipients, a comprehensive care plan to attend to recall procedures and patient distress is needed. It is suggested that recalls do not affect all ICD patients equally, with risk factors for poor psychological adjustment to ICDs including younger age (< 50 years), shock experience, and female gender that may be associated with increased recall anxiety. Specific recommendations for device recall management include formalizing clinic responses to recall before and after implantation and innovative uses of patient support systems to communicate recall responses.

Anxiety↗

Implantable cardioverter defibrillator implant-explant-implant case study: addressing the psychological adjustment to multiple shocks.

This case study details the multidisciplinary approach to a patient who underwent implantable cardioverter defibrillator (ICD) explantation for psychological reasons. The patient was unable to manage the stress associated with multiple shocks. He had a class I indication for an ICD but initially refused to undergo reimplantation. Treatment included the provision of comprehensive medical, nursing, and psychological care, with emphasis on patient autonomy and respect for the patient's experience.

Adaptation, Psychological↗

Device implant technique and consideration of body image: specific procedures for implantable cardioverter defibrillators in female patients.

OBJECTIVES: The purpose of this paper is to describe the psychological effects of implantable cardioverter defibrillator (ICD) implantation in female patients and to make clinical recommendations for providers to optimize health outcomes for women. BACKGROUND: Traditional ICD implantation produces visible scarring. Changes in physical appearance affect body image in all ICD recipients but may be more onerous in female ICD recipients. Electrophysiologists have described cosmetic approaches to device placement that appear promising and may warrant consideration in female patients. CONCLUSIONS: Active discussion and consideration of alternative device implant techniques are indicated in female patients. Female patients should also be given time to make preoperative decisions, and family members should be engaged in decision making. The investigation of cosmetic implants is noteworthy and could improve quality of life, adjustment, and psychological fitness of female ICD recipients.

Adaptation, Psychological↗

Measurement of patient fears about implantable cardioverter defibrillator shock: an initial evaluation of the Florida Shock Anxiety Scale.

BACKGROUND: Psychological distress is both a precipitant and a consequence of ICD shock. Therefore, the assessment of patient anxiety and concerns related to receiving an ICD shock may prompt appropriate psychological referrals and treatment. METHODS: The purpose of this study is to assess the initial validity and clinical utility of the Florida Shock Anxiety Scale (FSAS). Seventy-two ICD recipients completed the FSAS. RESULTS: Exploratory factor analysis revealed a two-factor structure with items loading such that Factor 1 could be conceptualized as a Consequence Factor (e.g., fearing creating a scene if the device were to fire) and Factor 2 as a Trigger Factor (e.g., fearing sexual activity). Alpha coefficients suggest good reliability (Cronbach's alpha= 0.91, split-half = 0.92), and FSAS Total Score was moderately correlated (r =-0.65) with total score on the Multidimensional Fear of Death Scale. CONCLUSIONS: Two subscales, labeled consequence of shock and trigger of shock, were established via factor analysis. Collectively the FSAS demonstrates potential utility to assess shock distress and warrants additional investigation.

Anxiety↗

Quality of death: implantable cardioverter defibrillators and proactive care.

OBJECTIVES: The purpose of this paper is to discuss quality of death (QOD) among patients with congestive heart failure (CHF) and implantable cardioverter defibrillators. We outline recommendations that enhance QOD from the device patient and specialty cardiology perspectives. BACKGROUND: Contemporary treatment of CHF patients routinely includes both pharmacologic therapy and the use of cardiac devices. The implantable cardioverter defibrillator prevents premature death in heart failure patients, though not death itself. CONCLUSIONS: Active discussion and consideration of patient's QOD is indicated in implantable cardioverter defibrillator patients to prevent unnecessary treatment and to increase control over perceived quality of life by patients and family.

Death↗

Using computers to improve the psychosocial care of implantable cardioverter defibrillator recipients.

Person-to-person psychosocial interventions (e.g., psychological, social) enhance the well-being of implantable cardioverter defibrillator (ICD) patients. Computerized care, though, represents an opportunity to further capitalize on techniques that have already been deemed effective. This includes the provision of tailored, effective patient education; reducing device-specific anxiety; and enhancing social support networks. The aim of this paper is to identify the ways in which computerized psychosocial care could potentially enhance the well-being of ICD recipients. For example, computers may be particularly adept at providing patient education due to the ease in which content can be adapted to meet patient needs. Further, evidenced-based treatments for anxiety and depression (e.g., cognitive behavioral therapy) have demonstrated good applicability to computerized formats. Social support can also be provided online in the form of bulletin boards, email list-servs, or structured online support groups. Despite the existence of some limitations, the use of computers in affecting psychosocial outcomes in implantable defibrillator recipients warrants greater attention.

Cognitive Behavioral Therapy↗

Management of heart failure after cardiac resynchronization therapy: integrating advanced heart failure treatment with optimal device function.

Cardiac resynchronization therapy (CRT) is an established adjunctive treatment for patients with systolic heart failure (HF) and ventricular dyssynchrony. The majority of recipients respond to CRT with improvements in quality of life, New York Heart Association functional class, 6-min walk test, and ventricular function. Management of HF after CRT may include up-titration of neurohormonal blockade and an exercise prescription through cardiac rehabilitation to further improve and sustain clinical outcomes. Diagnostic data provided by the CRT device may help to facilitate and optimize treatment. Initial nonresponder rates remain problematic. We suggest a simple step-by-step management and troubleshooting strategy that integrates device function with advanced HF therapy in patients who do not initially respond to CRT. This algorithm represents a new, comprehensive, collaborative approach between the HF and electrophysiology specialists to further improve and sustain outcomes in the field of CRT.

Adrenergic beta-Antagonists↗

Cardiac arrhythmias.

Explore the source record for details and available documents.

Arrhythmias, Cardiac↗

Depression as a predictor for appropriate shocks among patients with implantable cardioverter-defibrillators: results from the Triggers of Ventricular Arrhythmias (TOVA) study.

OBJECTIVES: We sought to examine the relationship between symptoms of depression and shock-treated ventricular arrhythmias among implantable cardioverter-defibrillator (ICD) patients. BACKGROUND: Depression predicts mortality in patients with coronary artery disease (CAD), but whether this is via an increased risk of fatal ventricular arrhythmias is unclear. METHODS: We prospectively analyzed data on symptoms of depression and risk of ventricular arrhythmia (ventricular tachycardia/ventricular fibrillation [VT/VF]) resulting in ICD discharge in the Triggers of Ventricular Arrhythmias (TOVA) study. Symptoms were assessed by the Center for Epidemiologic Studies-Depression (CES-D) scale. Scores of 16 to 26 and > or =27 represented mild and moderate/severe depression, respectively. The Cox and Anderson-Gill proportional hazards models were used to test for associations among all patients and patients with CAD. RESULTS: Among 645 patients with baseline assessments, 90 (14%) were mildly depressed and 25 (3.9%) were moderately to severely depressed. Moderate/severe depression was associated with time to first shock for VT/VF (hazard ratio [HR] 3.2, 95% confidence interval [CI] 1.1 to 9.9) and all shocks for VT/VF including recurrent episodes (HR 3.2, 95% CI 1.2 to 8.6). Among the 476 CAD patients, the association with time to first shock (HR 6.4, 95% CI 1.9 to 21.1) and all shocks (HR 8.3, 95% CI 2.9 to 23.3) remained. The risk of shock for VT/VF was associated with depression severity in the total population (p for trend = 0.02) and among patients with CAD (p < 0.01), even after controlling for multiple confounders. CONCLUSIONS: More severe symptoms of depression predict shocks for VT/VF among ICD patients. The elevated risk of VT/VF among patients with CAD and depression suggests that arrhythmia may contribute significantly to total mortality in this subgroup.

Cohort Studies↗

Use of cardiac resynchronization therapy to optimize beta-blocker therapy in patients with heart failure and prolonged QRS duration.

A retrospective analysis was performed on 52 patients with heart failure to determine the change in beta-blocker therapy after cardiac resynchronization therapy (CRT). After 6 months of CRT, the number of patients receiving beta-blocker therapy increased from 36 to 44, with improved clinical outcomes and larger beta-blocker doses, indicating that these 2 therapies may work together to improve outcomes by allowing the use of larger doses of beta blockers while correcting ventricular dyssynchrony.

Adrenergic beta-Antagonists↗

Current of injury predicts adequate active lead fixation in permanent pacemaker/defibrillation leads.

OBJECTIVES: The aim of this study was to determine whether current of injury can guide adequate placement of active-fixation pacing leads. BACKGROUND: Active-fixation leads cause injury to the myocardium at the time of fixation, manifested as a current of injury (COI) that may result in acute elevation of pacing thresholds. The relationship of COI to subsequent improvement in pacing thresholds is not clear. METHODS: Sixty-five patients undergoing active-fixation lead implantation were enrolled. Current of injury was characterized as the duration of the intracardiac electrogram (EGM) and the magnitude of ST-segment elevation. Pacing parameters were measured up to 10 min after fixation. RESULTS: A total of 96 active-fixation leads were studied, and 76 leads had a current of injury. From baseline to the time of fixation, the duration of the intracardiac EGM in ventricular leads increased from 150 +/- 31 ms to 200 +/- 25 ms (p < 0.001), and the ST-segment increased from 1.5 +/- 0.2 mV to 10.0 +/- 2.0 mV (p < 0.001), with subsequent improvement in pacing thresholds from 1.5 +/- 0.4 V to 0.8 +/- 0.3 V (p < 0.001) at 10 min. Atrial leads with a current of injury had similar findings. Of the 20 leads without a COI, 5 dislodged acutely and 15 had high pacing thresholds at 10 min, requiring repositioning. CONCLUSIONS: The development of a COI indicates that within 10 min of fixation, pacing threshold will return to an acceptable range even if the initial measurement is high. Conversely, without a COI, lead fixation is not adequate and the lead should be repositioned.

Aged↗

Ventricular reverse remodeling and 6-month outcomes in patients receiving cardiac resynchronization therapy: analysis of the MIRACLE study.

OBJECTIVE: The objective of this analysis was to determine if there were differences in ventricular reverse remodeling and 6-month outcome with cardiac resynchronization therapy (CRT) among specific subgroups enrolled in the Multicenter InSync Randomized Clinical Evaluation (MIRACLE) Study. BACKGROUND: Analysis of major subgroups receiving CRT is important in determining who may be most likely to benefit, since all patients who receive CRT do not demonstrate improvement. METHODS: Differences in response to CRT between subgroups based on baseline echocardiographic parameters, New York Heart Association (NYHA) class, age, gender, beta blocker use, and etiology of heart failure (HF) were analyzed for the clinical end points of the study as well as 6-month HF re-hospitalization or death. RESULTS: The benefit of CRT over control was similar in all subgroups with respect to all clinical endpoints. However, non-ischemic HF patients had greater improvements with CRT compared to ischemic HF patients in left ventricular end diastolic volume (P < 0.001) and ejection fraction (EF) (6.7% increase vs. 3.2% [P < 0.001]). Greater improvements in EF were also seen in those patients with less severe baseline mitral regurgitation (MR) (P < 0.001). Women but not men receiving CRT were more likely to be event-free from first HF hospitalization or death compared to the control group (Hazard Ratio = 0.157). CONCLUSIONS: The benefits of CRT with respect to EF and reverse remodeling were greater in patients with non-ischemic HF and less severe MR. Women may also derive more benefit than men with respect to the occurrence of HF hospitalization or death.

Aged↗

Left atrial tachycardia originating from the mitral annulus-aorta junction.

BACKGROUND: At the mitral annulus-aorta (MA-Ao) junction, the left atrium is continuous through the subaortic curtain with the musculature of the anterior mitral leaflet. Under experimental conditions, this region can generate abnormal electrical activity. In patients with left atrial tachycardia, we investigated whether this region could be the source of this arrhythmia. METHODS AND RESULTS: In 10 (28%) of 35 consecutive patients with left atrial tachycardia, the arrhythmia originated from the MA-Ao junction. Sustained, self-limited episodes of atrial tachycardia (cycle length, 340+/-56 ms; duration, 125+/-69 seconds) were repeatedly induced. Prematurity of the extrastimulus and time to first atrial tachycardia complex were directly correlated (R=0.66; P<0.001). During tachycardia, bipolar electrograms at the earliest site preceded onset of the P wave by 44+/-14 ms and were of longer duration and lower amplitude than those recorded from nearby left atrial sites (52+/-8 versus 24+/-4 ms, P<0.001; and 0.53+/-0.08 versus 3.45+/-0.96 mV, respectively; P<0.001). Ablation eliminated the tachycardia with no recurrence after a mean follow-up of 24+/-19 months. A comparative study in mouse embryos demonstrated the presence of the developing specialized conduction system in the MA-Ao region starting at embryonic age 11.5. CONCLUSIONS: The MA-Ao junction can be a frequent source of left atrial tachycardia. This previously unrecognized site of origin may explain why catheter ablation has been less successful in eliminating left versus right atrial tachycardias. Remnants of the developing specialized conduction system could be the underlying substrate of this arrhythmia.

Adrenergic beta-Agonists↗

The World Trade Center attack: increased frequency of defibrillator shocks for ventricular arrhythmias in patients living remotely from New York City.

OBJECTIVES: The goal of this study was to determine whether the World Trade Center (WTC) attack on September 11, 2001, had an effect on the occurrence of ventricular arrhythmias among patients with implantable cardioverter-defibrillators (ICDs) living in Florida. BACKGROUND: Increased frequencies of ICD therapies for ventricular arrhythmias were reported among patients in New York City after the attack on the WTC. Whether this effect also occurred in patients living geographically distant from New York is unknown. METHODS: This was an observational study consisting of 132 ICD patients who presented to the University of Florida and the Veterans Affairs Medical Center in Gainesville, Florida, for routine ICD follow-up around the time of the WTC attack. The occurrence of ventricular tachyarrhythmias triggering ICD therapy in the 30 days before and after September 11 constituted the primary end point. RESULTS: In the 30 days following the WTC attack, a total of 14 patients (11%) had ventricular tachyarrhythmias, compared with 5 (3.8%) in the preceding 30 days (p = 0.0389, 95% confidence interval [CI] 0.4 to 13.3). This represents a 2.8-fold risk increase. Patients with ventricular arrhythmias both before and after September 11 demonstrated a rate increase of 2.38 events per patient (p = 0.0231, 95% CI 1.03 to 13.97). CONCLUSIONS: The frequency of ventricular arrhythmias requiring ICD treatment increased by 68% among patients in Florida around the WTC attack. These findings suggest that stress-related arrhythmogenesis due to the WTC tragedy was not restricted to the geographic location of the attack. A major national tragedy may cause widespread increased risk of potentially life-threatening ventricular arrhythmias.

Adrenergic beta-Antagonists↗

Diffuse T-wave inversions associated with electroconvulsive therapy.

Electroconvulsive therapy (ECT) can lead to ST depression and arrhythmias in patients with coronary artery disease, most likely secondary to increased myocardial oxygen demand. This report describes a case of ECT-associated, global T-wave inversions in a patient with chronic atrial fibrillation treated with digoxin. Laboratory evaluation and echocardiography were normal. These T-wave changes may result from increased sympathetic activity associated with ECT. Prospective studies suggest that this finding may be seen in up to 4% of patients undergoing ECT.

Aged↗